electric power engineering

Slides:



Advertisements
Similar presentations
HIHI IVMAA - March 2005 Lessons from the ice storm of 1998 in Québec (from Bérubé Roger and C. Houde August 3, 2003) François Gauthier, f. eng., M. Sc.
Advertisements

Mitigation of AC Induced Voltage On Buried Metallic Pipelines
Utility Needs and Smart Grid for Major Storm Events July 11, 2013 Edward Gray, PE Director – Transmission and Distribution Engineering.
FPUA Storm Readiness 2007 Florida Public Service Commission Internal Affairs May 23, 2007 Craig Brewer- Superintendent of Electric T&D.
OVERHEAD LINE INSULATORS
Differential Equations
BREAKOUT SESSION 2 Smart Grid 2-B: Grid Integration – Essential Step for Optimization of Resources Integrating Intermittent Wind Generation into an Island.
CP2073 Networking Lecture 5.
Water Distribution Systems – Part 1
It all started simple…. One Alternator One Battery One Starter Motor.
S-Curves & the Zero Bug Bounce:
Insulation Resistance Calculations of Airfield Lighting Circuits
AEGEAN INTERCONNECTION PROJECT Athens, 24 th May, 2011.
© 2009 Dominion August 5, 2009 Underground Transmission Lines at Dominion Virginia Power Update for the Joint Committee on Technology and Science Presented.
Digital Components Introduction Gate Characteristics Logic Families
EE369 POWER SYSTEM ANALYSIS
Chapter 11 AC Power Analysis
Charging System Tests & Voltage information Checking the charging system with just a volt meter.
7. PV System Sizing Herb Wade Consultant
Direct-Current Circuits
Scale Free Networks.
PS – TEST 8TH GRADE SCIENCE.
1 Applying Math to Wire Sound Using formulas and conversions to wire up sound.
Quantitative Analysis (Statistics Week 8)
Elasticity of Demand and Supply
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
AC/DC POWER SUPPLY An alternating current (AC) is an electrical current whose magnitude and direction vary cyclically, as opposed to direct current (DC)
1 Smart Grid Vision Electric Grid Modernization Steering Committee Grid Facing Technology Subcommittee January 14, 2013.
Addition 1’s to 20.
25 seconds left…...
Electric Current Voltage Resistance
Week 1.
TS01 Klystron Modulator Minh Nguyen May 20, 2014 Beam Voltage Stability Improvements.
1 McGill University Department of Civil Engineering and Applied Mechanics Montreal, Quebec, Canada.
Algebra Problems… Solutions Algebra Problems… Solutions © 2007 Herbert I. Gross Set 17 part 3 By Herbert I. Gross and Richard A. Medeiros next.
Electric Power Distribution
EE 369 POWER SYSTEM ANALYSIS
Lecture 2 Complex Power, Reactive Compensation, Three Phase Dr. Youssef A. Mobarak Department of Electrical Engineering EE 351 POWER SYSTEM ANALYSIS.
Complete Quiz You have 10 minutes to complete the quiz The Quiz is Open-Book (use it) Get help from your neighbor.
Announcements Be reading Chapters 9 and 10 HW 8 is due now.
The Power Grid ELEC 403 The Citadel Mark McKinney.
Lecture 26 Distribution Systems Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
ECE 333 Renewable Energy Systems Lecture 13: Per Unit, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Chapter 7 SYSTEM PROTECTION
Transmission Lines …….. Conductor Material
EE369 POWER SYSTEM ANALYSIS
1 Introduction to Power Systems Expensive! Influential!Intrusive! Source: Riadh W. Y. Habash, Electromagnetic Fields and Radiation, Marcel Dekker, New.
Power Systems Last edited: Monday, June 1 st, 2015.
CITY OF LAKE WORTH, FLORIDA UTILITIES DEPARTMENT A Look at our Electric Utility A Plan For The Future.
Section 3 TRANSMISSION & DISTRIBUTION US Bulk Power Transmission System Transmission & Distribution (T&D) Components New T& D Technologies This product.
ELG4125 Transmission and Distribution Systems
Utility Engineers, PC.  Generation  Transmission  Distribution.
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
Distribution Systems-General
Glades Electric Cooperative Infrastructure Miles of Line 2,213  Overhead Dist.2,180  UndergroundDist. 33  Transmission 87 16,402 meters Average 7.
HVDC Transmission.
ELECTRICAL INSTRUMENTS ( service and utilization )
Electrical Power System
Sub Station.
AHMEDABAD INSTITUTE OF TECHNOLOGY
Utility Needs and Smart Grid for Major Storm Events
SUB-STATIONS.
Power Generation and Distribution
Introduction To Reactive Power
Design of Electric Power Systems and Utilities
Protective Relaying Conference
Factors to Consider when Designing a Reliable Power Grid
Factors to Consider when Designing a Reliable Power Grid
Presentation transcript:

electric power engineering Underground vs. Overhead Transmission and Distribution June 9, 2009 Your Power System Specialists NEI Electric Power Engineering

NEI Electric Power Engineering NATIONAL TRENDS Municipalities have passed laws requiring new distribution facilities to be placed underground. For aesthetic reasons To increase property values (5-10% according to some studies) Cost covered by developers and ultimately paid by property owners. Provide better protection from storm damage and improve reliability of power supply. NEI Electric Power Engineering

Underground Construction and Storm Protection Underground construction CAN improve the reliability of the electric power system by minimizing damage to the system from: High winds Ice and snow storms Falling trees If part of the system is impervious to storm caused damage faster restoration of the system is possible. NEI Electric Power Engineering

Underground Construction is NOT Immune from All Storm Damage Flooding Hurricane Damage Earthquake Damage Lightning Damage Rodent and Human Damage (dig up) NEI Electric Power Engineering

Power System Components Transmission System 69,000 Volts and Above Less than 2% of all outages are due to transmission system outages. Subtransmission System 35,000 Volts Sometimes 69,000 Volts NEI Electric Power Engineering

Power System Components Distribution System 25,000 Volts and below Most outages occur here NEI Electric Power Engineering

Physical Limitations of Underground Lines The main argument against constructing underground systems is usually financial. But costs are not the only limitation. The laws of physics limit how physically long a power line can be. These limits are relatively unimportant on overhead lines but will severely limit high voltage underground cable systems. The higher the voltage the shorter the line length must be. The limiting effects become very important at transmission voltages, especially 100,000 Volts and above. Limiting effects may also be important for subtransmission voltages, 69,000 Volts and 35,000 Volts. NEI Electric Power Engineering

Physical Limitations of Underground Transmission Lines What is the limit? And Why? NEI Electric Power Engineering

Physical Limitations: The Effect of Capacitance Capacitance causes current to flow even when no load is connected to the cable. This is called “line charging current”. Underground line capacitance for power cables is far higher than overhead line capacitance. Wires are closer to each other Wires are closer to the earth (within a few inches). Underground lines have 20-75 times the line charging current that an overhead line has (depending on line voltage). If a line is long enough the charging current could be equal to the total amount of current the line can carry. This will severely limit its ability to deliver power. NEI Electric Power Engineering

Widespread Underground Transmission Systems are Not Practical A typical 345,000V transmission line will be able to deliver no power when the line becomes about 26 miles long. The longest underground circuits at 230,000 or 345,000V are 20 miles long. Replacing overhead with underground lines will also change other characteristics of the line and connected power system. Resistance will go down (probably beneficial) Inductance (resistance to the flow of AC current) will also go down. Voltage regulation will become much more difficult. Line losses may increase and efficiency might become worse. Time to repair the line will be much longer, an unacceptable condition for a transmission line since outage times are limited. NEI Electric Power Engineering

Other Transmission Issues Widespread changes to underground cable in New Hampshire would cause power flow, voltage regulation, system stability, and other unforeseen changes over the whole NE grid. System studies will be needed to determine the effect of line characteristic changes. NERC requirements could produce hidden costs. Presently available switching devices (circuit breakers) may not be capable of switching long underground lines. Massive re-engineering of the entire NE power grid may be needed. Underground transmission line construction may be 20 times the cost of overhead construction. (A $3 million/mile line becomes $60 million/mile.) NEI Electric Power Engineering

NEI Electric Power Engineering Other Issues Currently underground AC transmission is primarily used only where nothing else will do. River Crossings In dense urban areas Large road crossings Where aesthetic issues are paramount (national parks) Aspen, Colorado: Special tariffs were imposed on customers. A move to install underground transmission cables may require a conversion from AC to DC transmission. Long underground DC Transmission systems are possible. DC Transmission does not suffer from the same problems as AC. DC Transmission has its own additional costs, primarily converter stations. Studies would still be needed to determine the effects on the NE power grid of a widespread conversion to DC transmission. NEI Electric Power Engineering

How about 35kV Subtransmission? Underground 35kV is becoming common. Wind farms Some cities have installed 35kV underground distribution. HOWEVER: Problems are occurring. Ferroresonance problems Early switchgear and cable failures. Time to repair underground lines exceeds overhead lines and may offset any reliability advantage. Charging current switching limitations of available breakers/reclosers limit line length to less than 15 miles. NEI Electric Power Engineering

Distribution: 15kV and Below 80% of all outages occur on the distribution system. 15kV underground distribution is becoming very common for new lines. The number of outages due to underground distribution are far less than overhead distribution. An improvement of up to 10 times is possible when lines are placed underground. HOWEVER: Time to repair, outage duration, is much longer (up to 10 times longer) for radial distribution systems (the most common type). The two effects counterbalance each other and underground radial lines may be no more reliable than overhead lines. They will be impervious to widespread outages due to ice. Underground systems are harder to modify. NEI Electric Power Engineering

The Main Objection to Underground Distribution Lines Can Be Solved The distribution system can be changed from radial to looped. This greatly reduces outage time. Radial Distribution System NEI Electric Power Engineering

Looped Distribution System Using a looped distribution system can minimize outage duration time and still keep the advantage of infrequent outages inherent in underground construction. Installing spare conduit can also facilitate repair. Reliability indices SAIDI, SAIFI, CAIDI will nearly always improve when switching to this type of system. One type of looped distribution system. NEI Electric Power Engineering

Underground Distribution System Costs Underground distribution system costs vary greatly depending on conditions. Easements and indemnifications must be obtained from owners. Soil conditions can greatly affect costs. At times placing lines underground may simply not make sense. Overhead lines may have considerable life left. Repairing, patching, and restoration costs can vary greatly. A price of $3,500/customer is cited in many studies, and has been shown in practice, to be the average cost for converting to underground construction in a municipal distribution system where certain conditions apply. If it is done as a long term (many decade) project. If it is done in coordination with other projects like road repair. If it is done in conjunction with retiring old overhead lines. If the municipality passes ordinances making underground lines required for new construction and new costs are passed to homeowners. NEI Electric Power Engineering

Underground Distribution System Costs A price of $3,500 per customer would double the rate charged for electricity. Estimates from varying sources say rates would increase 110-150%. Rates may not return to near previous levels until the original investment is paid off (25-40 years). This estimate applies only to cases where underground conversion presents no unusual problems: municipal distribution systems which can be easily looped and where no unusual conditions apply. This estimate does not apply to placing 100% of the State’s distribution system underground. The four utilities serving New Hampshire have provided information which indicates that the cost of a project to place 100% of the State’s distribution system underground would be in excess of $40,000.00 per customer. NEI Electric Power Engineering

Summary of Costs: Overhead vs. Underground Transmission: Underground may be 4-20 times Overhead. Subtransmission: Underground may be 4-20 times Overhead. Distribution: Underground may be 2-10 times Overhead. New underground may be cheaper than overhead in special conditions and costs vary greatly from utility to utility and place to place. NEI Electric Power Engineering

NEI Electric Power Engineering Conclusion It will cost more to place lines underground than overhead. Underground lines are protected from some, but not all, types of storm damage. Replacing all the overhead lines in a state (transmission and distribution) with underground lines is probably not possible or desirable. It is highly impractical (and probably impossible) to place all AC transmission lines underground. Selective short underground installations are possible. 35kV subtransmission systems may be placed underground if less than approximately 15 miles, however other problems may occur. It may be beneficial to place 15kV distribution systems underground if the installation costs are acceptable and if the system can be configured as a looped system. NEI Electric Power Engineering

Q&A Keith Malmedal Ph.D. P.E, P.Eng. NEI Electric Power Engineering P.O. Box 1265 Arvada, CO 80001 303-431-7895 kmalmedal@neiengineering.com NEI Electric Power Engineering