Genesis Series Cable Product Training

Slides:



Advertisements
Similar presentations
Feichter_DPG-SYKL03_Bild-01. Feichter_DPG-SYKL03_Bild-02.
Advertisements

1 Copyright © 2013 Elsevier Inc. All rights reserved. Appendix 01.
Chapter 4 Signal Transmission Network Media
Network Hardware and Physical Media
Cables. Technical reading Transmission lines Write down any types of cable and transmission lines used in telecommunications that you can think of. Now.
BREAKOUT SESSION 2 Smart Grid 2-B: Grid Integration – Essential Step for Optimization of Resources Integrating Intermittent Wind Generation into an Island.
Break Time Remaining 10:00.
About ICM ICM Corporation is the global manufacturer of our patented 360° radial compression technology in both connectors and tools. Our F-Conn connectors.
Cabling system components
IST 126 Transmission Media. Characteristics of Transmission Media Cost Ease of installation Bandwidth capacity – the amount of data that can be sent in.
Cable Management.
7.1 Chapter 7 Transmission Media Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Thinnet (10Base2) Characteristics (cont.): Size and scalability
Introduction to Network
Lecture 7 Cabling: Types and Termination
9-Jun-14Data Link Layer Guided Media Media that provide a conduit from one device to another. Signals travelling along any of these media is directed and.
Physical Media PHYSICAL MEDIA.
25 pair color code and high count cables
N ETWORKING MEDIA. COMMON NETWORK CABLES The connection between the source and destination may either be direct or indirect, and may span multiple media.
Residential Telecommunications Infrastructure Standard
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public 1 Version 4.0 OSI Physical Layer Network Fundamentals – Chapter 8.
1000BASE-T Technology Overview
HDMI cables May 2009
15. Oktober Oktober Oktober 2012.
1..
Model and Relationships 6 M 1 M M M M M M M M M M M M M M M M
: 3 00.
DCN286 Introduction to Data Communication Technology Session 5.
1 Troubleshooting. 2 Introduction This section provides you with the necessary skills to effectively troubleshoot the DIRECTV System.
Clock will move after 1 minute
Select a time to count down from the clock above
Murach’s OS/390 and z/OS JCLChapter 16, Slide 1 © 2002, Mike Murach & Associates, Inc.
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
Hands On: Cutting and Connectorizing UTP Chapter 3a Panko’s Business Data Networks and Telecommunications, 6 th edition Copyright 2007 Prentice-Hall May.
Introduction to Network (c) Nouf Aljaffan
Telecommunications cable types
CS335 Networking & Network Administration Thursday April 1.
Network+ Guide to Networks, Fourth Edition Chapter 3 Transmission Basics and Networking Media.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
Network Cabling. Introduction Cable is the medium through which information usually moves from one network device to another. There are several types.
1 Telecom Cabling CATV systems and coax cable. 2 Telecom Cabling Community antenna TV is covered in the NEC article 820, and is covered in a limited capacity.
Router. Switch Repeater Cable is the medium through which information usually moves from one network device to another. It used to connect one network.
1 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Objectives By end of this module you should able to: Know What Really.
Transmission lines.
Cisco 1 - Networking Basics Perrine. J Page 19/3/2015 Chapter 3 Which of the following correctly describes the type of signal that the network media carries?
Communication channels and transmission media
Physical Transmission
1 CCTV SYSTEMS CCTV cables. 2 CCTV SYSTEMS Cable selection is a very important consideration in the performance of a CCTV system, especially where long.
Introduction to Network (c) Nouf Aljaffan
Transmission Media The physical pathways that connect computers and devices on a network.
SYSTEM ADMINISTRATION Chapter 4 Network Media, Connectors, and Their Characteristics.
Lecture 8 Cable Certification & Testing:. Cable Distribution Cable Distribution Equipment UTP (Unshielded Twisted Pair) UTP Cable Termination Tools UTP.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
 Cables  Network Interface Card (NIC)  Repeaters  Hubs  Switches  Routers  Gateways  Bridges.
COPPER AND FIBER REVIEW
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
Lesson 2—Networking BASICS1 Networking BASICS Network Media Unit 1 Lesson 2.
Network Cabling Presentation by: Dani Johnson, Dominik Pecararo, Tommy Yowell.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Transmission Media The transmission medium is the physical path by which a message travels from sender to receiver. Computers and telecommunication devices.
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
Chapter Four Networking Media. Chapter Objectives  Explain concepts related to data transmission and noise  Describe the physical characteristics of.
Official Association Sponsor
Introduction to Computers
Hands On: Cutting and Connectorizing UTP
Hands On: Cutting and Connectorizing UTP
Hands On: Cutting and Connectorizing UTP
Presentation transcript:

Genesis Series Cable Product Training

Basic Cable Construction Insulation Drain Jacket Rip Cord Shield Conductor

Conductor Solid Stranded Bare copper is less expensive Tinned copper Reduces Corrosion Soldering Stranded More Flexible Increase surface/frequency response Bare copper is less expensive Tinned copper Need when soldering connector to the wire or in a corrosive environment (where temps over 100 degrees C or near salt water) See this in Belden’s line, can convert if not installing in the above environment Solid Bare Copper Solid Tinned Copper Stranded Bare Copper Stranded Tinned Copper

Cable Jacket

Gauge Size can have an impact on performance Factors: Length of Run Conductor Gauge Size can have an impact on performance Factors: Length of Run System Manufacturer’s requirements Remember: the larger the number, the smaller the gauge 24 AWG is the smallest gauge we carry

Straight Lay or Cabled Straight Lay Cabled Cost effective in installations where interference is not a concern. Cabled Assists in reducing EMI and RFI interference EMI - Electro Magnetic Interference May be caused by electric motors, ballast, etc RFI - Radio Frequency Interference

Straight Lay

Conductors Cabled

Shielding The addition of a shield offers increased resistance to EMI and RFI Shield Types Aluminum Backed Mylar Tape All Aluminum/Mylar shielded cables include a drain wire Bare Copper Braid and Tinned Copper Braid We currently only carry this in coax

Overall Shielded Cables

Each Pair Shielded

Wire Types Shielded vs. Unshielded Stranded vs. Solid There are a variety of overall shielded (OAS) products Offers increased resistance to EMI & RFI interference and added protection against cross talk Stranded vs. Solid Though cost is slightly higher, stranded cables afford greater flexibility and ease of installation Multi-Pair Cables Variety of cables available typically per preference of residential or commercial installer Helpful Hint: Look at similarities in Part #’s #1204 = 22/4 STR Non-Plenum OAS #2204 = 22/4 STR Riser OAS #3204 = 22/4 STR Plenum OAS

Wire Types Plenum (CMP, FPLP) Riser (CMR, FPLR) Non-Plenum (CM, FPL) Cables used in air space (plenum ducts / ceilings; is the space that can facilitate air circulation for heating and air conditioning systems) must have fire-resistant, low smoke producing characteristics Plenum constructions are very similar to non-plenum but more expensive Much of plenum cable products used in commercial applications Riser (CMR, FPLR) Suitable for use in a vertical run (floor to floor) Fire resistant characteristics preventing fire from traveling from floor to floor Non-Plenum (CM, FPL) General Purpose Listing excludes installation in risers & plenums Bulk of what we manufacture & sell Helpful Hint: Look at similarities in Part #’s #1104 = 22/4 STR Non-Plenum #2104 = 22/4 STR Riser #3104 = 22/4 STR Plenum

Plenum Cable Installation Floor Structural support Plenum Cables Plenum Air Handling Space Air Supply Duct Suspended Ceiling Air Return Riser (or Plenum) Cable Access Shaft

More commonly used in commercial installations Plenum Cable More commonly used in commercial installations Low flame spread Low smoke producing characteristics.

What makes a good speaker wire? Stranded conductors More strands = more flexible Promotes “Skin Effect” The signal travels on the outside of the conductor, like the skin is on the outside of your finger. The more strands, the more “outsides” or surface area for the signal to travel across…so the better it travels Oxygen Free Oxygen is a natural impurity in copper Copper can be annealed to remove that oxygen Just like these pennies, speaker wire can oxidize Oxidized strands will impede the signal Oxygen-Free speaker wire will not oxidize over time

What makes good speaker wire Zip Construction vs. Cabled Construction Subject To Interference Reduces Interference Easy to strip Home Theater Sound, Home Theater Sound Plus & Audacious Genelene Insulated Conductor + Semi-Loose Tubed PVC Jacket Jacket won’t stick to the insulation like PVC + PVC constructions Crystal Series Genelene Insulated Conductor + Pressure Extruded TPE Jacket Most flexible, easy to use speaker wire Easy to label Speaker, Room & Zone Code on Legend L= Left LR= Left Rear C= Center RR= Right Rear R= Right Speaker Code Room Code Zone Code

Speaker Wire…Power Loss Analog Transmission of a signal degrades as the length of the run increases. Your speaker requires a maximum amount of loss. Use this chart to decide what gauge speaker wire you need For 0.5 dB loss (or 11%) 16 AWG 0’ 60’ 100’ 120’ 190’ 4 Ω 4 Ω = 4 Ω Speaker 8 Ω 8 Ω = 8 Ω Speaker 14 AWG 4 Ω 8 Ω

Coaxial Review Conductor Dielectric Solid or Stranded Bare Copper Tinned Copper Copper Clad Steel Dielectric Foamed Polyethylene Solid Polyethylene Foamed FEP Solid FEP Gas Injected Shields Aluminum Foil Aluminum Braid Bare Copper Braid Tin Copper Braid Jacket PVC Polyethylene (PE) FEP

Coaxial Cable Copper Shield CCTV Dielectric Core Braid Shield Typical CCTV construction BC braid shield. Center Conductor Jacket

Coax Foil & Braid Shield CATV & MATV Tape Shield Dielectric Core Typical CATV construction Alum foil and braid shield Center Conductor Braid Shield

Coax Quad Shield Tape Shield Dielectric Core Tape Shield Center Braid Conductor Quad shield construction foil-braid-foil-braid Jacket Shield Shield

Attenuation Comparison (Signal loss over distance) The lower the dB/100ft at 1000MHz and 3000MHz the better the cable

Coax RG6 CATV RG59 CCTV See handout for coax run lengths Do not pull with more than 35lbs Max. bend radius is 3 inches RG59 CCTV Max. pull strength of 25lbs Max bend radius of approx. 2.5 inches See handout for coax run lengths

Applications for Category Cable Voice only networks 10/100 Mbs No future-proofing Cat 5e Voice and Data networks Gigabit Ethernet Cat 6 Data Networks 10 Gigabit Ethernet Commonly used in hospitals, schools, large offices, etc.

Category Rating System (What you hear about) (ENHANCED) Cat 6 Standard Frequency (MHz) 16 20 100 350* 250 Genesis Frequency 32 40 200 350 500 Network Throughput 10 Mbps 100 Mbps 1 Gbps 1 Gbps 10 Gbps *Cat5 350 (aka ENHANCED or Cat5E) is not regulated by the TIA Category Rating system, therefore users should not assume Cat5e compliance on all electrical values. Consult factory for complete test results.

What’s really important? Although Frequency is the electrical characteristic most often discussed with category cable it is not the best indicator of network performance. When a manufacturer says their cable is tested at a certain level, ask for the test results. Most ‘low end’ manufactures that claim a high frequency rating do not meet the TIA specifications for all electrical values. Better indicators of network performance are: Near End Cross Talk How much adjacent pairs “accidentally share information” Reflection How much interference there is based on signal accidentally reflecting (changing direction) due to cable imperfections ACR Attenuation to Crosstalk Ratio is the amount of signal relative to the amount of noise. (The higher the better)

What’s really important? (cont.) Near End Cross Talk – how does it go bad? Category cable has four pairs that are each twisted in a slightly different way. Those four pairs are also cabled together in a specific ways too. This twisting scheme is like the lane lines on a highway. The Category Rating System specifies a certain type of twisting scheme that allows the signals to travel optimally. The signal travels with peaks and valleys that, when on a quality category cable, work well together. If there are any imperfections in the way that cable is designed or manufactured those twists can fall out of place, and the peaks and valleys begin to interfere with each other. Improper installation is also a major cause of those twists falling out of place. Imagine a highway where the lane lines were to run together, cars would be cutting each other off, and the traffic would slow down.

When am I going to notice a problem? Before Cat 5e the best networks were transmitting 10 or 100 Megabytes per second. They are often referred to as 10/100 networks and are still the most popular today among small networks. Cat 5e was designed for Gigabit Ethernet (1,000,000 bytes of information per second) Gigabit Ethernet is available on many computers and network devices purchased in the last few years. Cat 6 was designed for 10 Gigabit Ethernet (10,000,000 bytes of information per second)

When am I going to notice a problem? Gigabit and 10 Gigabit Ethernets transmit data in a new way. Before Cat 5e: 2 pairs were used for sending information & 2 pairs were used for receiving information With Cat 5e and beyond: All 4 pairs send and receive information Imagine both sides of the highway Since each pair is transmitting and receiving a signal on Cat 5e and Cat 6, interference due to reflection becomes much more disruptive.

When am I going to notice a problem? Little problems within a network build up until a point at which the network fails. Too many users on a network: More bandwidth is used up More errors will occur Network will slow down Cable runs too long within a network: Cable runs are not to exceed 100 meters (328 feet) 90 meters (295 feet) from distribution device to outlet. Maximum 10 meters (33 feet) for Equipment Cords and Patch cords Maximum Demarcation to furthest outlet can’t exceed 150 meters (492 feet) Cable improperly installed Cable daisy chained Cable pulled with more than 25 lbs. of pulling tension. Pairs untwisted more than ½” when terminating Cable bent beyond 1” bend radius

Genesis Part Numbers

Catalog Your wire & cable lifeline Sections Security & Control Thermostat Fire Crystal Series (HDMI & Interconnects) Home Theater Multimedia Networking (Voice & Data) COAX

Part Numbers All Genesis Series products come with an 8 digit part # The first 4 digits represent the product The next 2 digits represent the put-up The last 2 digits represent the color code For Example: #1103 1103 = 22/4 SOL 55 = 500’ Pull Out Box 09 = Gray #11035509 Code Color 00 Clear 01 White 02 Yellow 03 Orange 04 Red 05 Green 06 Blue 07 Brown 08 Black 09 Gray 10 Purple 11 Pink 12 Natural / Beige 40 Violet 41 Fluorescent Pink Code Put-Up 00 100’ Pack 02 250’ Reel 10 1000’ Reel 11 1000’ Box 18 1000’ Speedbag 21 1000’ Reel-In-Box 50 500’ Reel 55 500’ Box 58 500’ Speedbag 61 500’ Reel-In-Box

Part Number (18/4 FPLP) Put Up (1000’ Pull Box) Color (Red)

Tools & Resources Genesis Website (www.genesiscable.com) SPECS Product literature & cut-sheets More training Genesis Outside Sales Randy Lee-- Director of Electrical Distribution Brian Stock– Regional Sales Manager Don Straka– Regional Sales Manager Genesis Factory PH: 800-222-0060 Tiffany Cram—Inside Sales Nicole Ricard—Inside Sales Leann Meachum—Inside Sales Manager/Marketing

www.honeywell.com This is the closing slide that should appear at the end of all presentations. If you are using an existing presentation, you should copy this slide and insert it at the end. The old Honeywell closing slide, with the red background and tagline “Helping You Control Your World” should not be used. This slide should not be altered in anyway. Do not add any additional elements to the slide, alter the web address, add additional copy, etc. Use it as it appears here. 18 4 4