ITNW 1325, Chapter III, Part II

Slides:



Advertisements
Similar presentations
Chapter 4 Signal Transmission Network Media
Advertisements

Network Hardware and Physical Media
Cabling system components
IST 126 Transmission Media. Characteristics of Transmission Media Cost Ease of installation Bandwidth capacity – the amount of data that can be sent in.
Physical Media PHYSICAL MEDIA.
Conducted and Wireless Media (Part I) School of Business Eastern Illinois University © Abdou Illia, Spring 2014 (February 26, 2014)
Thinnet (10Base2) Characteristics (cont.): Size and scalability
Introduction to Network
Transmission Media Semester: 131 Course: CSET 221 Computer Networking
Transmission medium We can say that transmission media belong to layer zero.
9-Jun-14Data Link Layer Guided Media Media that provide a conduit from one device to another. Signals travelling along any of these media is directed and.
Modern Ethernet UTP and Fiber Optic Cable-based Ethernet
Physical Media PHYSICAL MEDIA.
Computer Communication & Networks
N ETWORKING MEDIA. COMMON NETWORK CABLES The connection between the source and destination may either be direct or indirect, and may span multiple media.
Chapter 7 Transmission Media
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
Guide to Network Cabling Fundamentals
Introduction to Network (c) Nouf Aljaffan
CS335 Networking & Network Administration Thursday April 1.
1 Part II: Data Transmission The basics of media, signals, bits, carriers, and modems Fall 2005 Qutaibah Malluhi Computer Science and Engineering Qatar.
Network+ Guide to Networks, Fourth Edition Chapter 3 Transmission Basics and Networking Media.
Chapter 7 Transmission Media
Classes of transmission media
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
1 Physical Media. 2 physical link: what lies between transmitter & receiver guided media: –signals propagate in solid media: copper, coax, fiber unguided.
Coaxial Cable Coaxial cable (or coax) carries signals of higher frequency ranges than those in twisted pair cable, in part because the two media are constructed.
Network Cabling. Introduction Cable is the medium through which information usually moves from one network device to another. There are several types.
Router. Switch Repeater Cable is the medium through which information usually moves from one network device to another. It used to connect one network.
Media Chapter 2. Two types of Cables Baseband Broadband.
Physical Layer Data Encoding Transmission media Signals Bits to signal transformation  Timing (bit rate)  Synchronization.
The physical network Unit objective: Identify network cables and connectors, and use networking tools.
Transmission lines.
Wire Media: UTP Unshielded Twisted Pair (UTP) –Ordinary copper wire –Twisted several times per inch to reduce interference –Pair of wires needed for a.
7.1 Chapter 7 Transmission Media Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Communication channels and transmission media
Physical Transmission
1 CCTV SYSTEMS CCTV cables. 2 CCTV SYSTEMS Cable selection is a very important consideration in the performance of a CCTV system, especially where long.
Physical Transmission
Introduction to Network (c) Nouf Aljaffan
Transmission Media The physical pathways that connect computers and devices on a network.
CSCI 465 Lecture 5 Martin van Bommel CSCI 465 Data Communications and Networks 1.
SYSTEM ADMINISTRATION Chapter 4 Network Media, Connectors, and Their Characteristics.
Lecture 8 Cable Certification & Testing:. Cable Distribution Cable Distribution Equipment UTP (Unshielded Twisted Pair) UTP Cable Termination Tools UTP.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
Five components of data communication
Computer Networking Dinesh Kumar Ram PGT Comp.Sc. KV NAD Aluva.
 Cables  Network Interface Card (NIC)  Repeaters  Hubs  Switches  Routers  Gateways  Bridges.
CT1304 LAN LAB Rehab AlFallaj. LAN PHYSICAL LAYER Networks are consist of: Nodes: Service Units: PCs. Processing and interface Units Transmission medium.
TRANSMISSION MEDIA.  Factors that directly influences the choice of correct media type;  Transmission rate  Distance covered  Cost & ease of installation.
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
Telecommunications and Networking
Lesson 2—Networking BASICS1 Networking BASICS Network Media Unit 1 Lesson 2.
Network Cabling Presentation by: Dani Johnson, Dominik Pecararo, Tommy Yowell.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
© ExplorNet’s Centers for Quality Teaching and Learning 1 Differentiate among various types of network cables and connectors. Objective Course Weight.
Lecture 2 unit 1.
Chapter Four Networking Media. Chapter Objectives  Explain concepts related to data transmission and noise  Describe the physical characteristics of.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Fatima Alibrahim Intro. to Telecommunication MISY3312
Level 2 Diploma Unit 10 Setting up an IT Network
Network Media Types COMPUTER NETWORKS 4TH Edition Chapter3
Introduction to Computers
Introduction to Computers
CT1403 Lecture#1:Transmission Media
Conducted and Wireless Media (Part I)
Computer Networks Topics: Twisted Pair and Fiber Optic Cable
NETWORK COMPONENTS PHYSICAL MEDIA
Physical Media PHYSICAL MEDIA.
Network+ Guide to Networks 7th Edition
Presentation transcript:

ITNW 1325, Chapter III, Part II Network Cables ITNW 1325, Chapter III, Part II

Coaxial Cable

Coaxial Cable Overview: Was the foundation of Ethernet networks in 1970s – replaced by newer twisted pair and fiber cable Has a single or multiple copper strands at its center – protected by PVC or Teflon insulation Protected and grounded via metallic shield (“braiding”) Protected from physical damage by a layer of dielectric insulator (“sheath”) on the outside Allows relatively long segments and highly resistant to noise – more expensive and less convenient to handle

Coaxial Cable Overview (continued):

Coaxial Cable Overview (continued): Defined by Radio Guide (RG) specifications – with few most common types in use Classify the cores according to American Wire Gauge (AWG) numbers – the smaller is the diameter, the larger is the AWG number Differ by materials used for the core and for shielding, the core’s diameter, impedance, attenuation, data rates, and terminators used

Coaxial Cable RG-6: Contains an 18 AWG conducting copper core with an impedance of 75 ohms – thick and not flexible Used for delivering cable TV and Internet service over long distances to residential areas – not used for LANs

Coaxial Cable RG-6 (continued):

Coaxial Cable RG-8 (“Thicknet”, “10Base5”): Contains an 10 AWG conducting copper core with an impedance of 50 ohms – very thick and inconvenient Allowed throughput up 10 Mbps with a maximum segment length of 500 m Used within first baseband (Ethernet) data networks

Coaxial Cable RG-8 (continued):

Coaxial Cable RG-58 (“Thinnet”, “10Base2 Cable”): Contains a 24 AWG conducting copper core with an impedance of 50 ohms – thin and quite flexible Allowed throughput up 10 Mbps with a maximum segment length of 185 m Entirely replaced the 10Base5 cable within baseband data networks – popular in mid-80s and 90s

Coaxial Cable RG-58 (continued):

Coaxial Cable RG-59: Contains a 20 or 22 AWG conducting copper core with an impedance of 75 ohms – thin and quite flexible Allowed throughput up 10 Mbps with a maximum segment length of 185 m Used for delivering video signals for short distances Less expensive than RG-6 but suffers from attenuation

Coaxial Cable RG-59 (continued):

Coaxial Cable Termination

Coaxial Cable Termination Overview: Necessary to avoid bouncing of the signal off the cable’s ends – accomplished by using connectors or special terminators with the same impedance as the cable used Two common types – F-type and BNC F-Connector: Suitable for cables with a solid metal core – becomes the pin in the center of the connector (used in RG-6) Mounted on a cable by crimping or compression – both male and female connectors are threaded and screw together like a nut and bolt assembly

Coaxial Cable Termination F-Connector (continued): Male Female

Coaxial Cable Termination Bayonet Neill-Concelman (BNC) Connector: Mounted on a cable by crimping, compression, or twisting – connects to another BNC connector via a turning and locking mechanism (“bayonet coupling”) Male connector uses its own conducting pin – not the core of the cable like F-type ones Commonly used with RG-59 cable

Coaxial Cable Termination BNC Connector (continued): Male Female

Coaxial Cable Termination BNC Connector (continued):

Twisted Pair (TP) Cable

Twisted Pair Cable Overview: Carries color-coded pairs of insulated copper wires Wires in each pair are twisted around each other – from 1 to 4200 pairs depending on the cable type Inexpensive, flexible, easy to install Twist ratio – the number of twists per meter – measures resistance to crosstalk Higher twist ratio leads to lesser crosstalk but requires more cable – increases attenuation and raises the cost

Twisted Pair Cable Overview (continued): Uses a variety of twist ratios, pair numbers, copper grades, shielding types, etc. The TIA/EIA 568 standard defines categories – CAT5, CAT6, or CAT7 TP cable is needed for modern LANs Comes in two types – shielded and unshielded

Twisted Pair Cable Shielded (STP): Shielding prevents external EM forces from distorting the signal traveling in the wires Each pair in individually insulated and surrounded by metallic shielding Grounded shielding enhances its protective effects Noise, shielding material, quality, and symmetry, and grounding affect the protection provided

Twisted Pair Cable Unshielded (UTP): Employs no shielding – contains insulated wire pairs encased in a plastic sheath only Provides acceptable resistance to and less expensive than STP – widely used on computer networks

Twisted Pair Cable STP vs. UTP: Provide same levels of throughput – from 10 Mbps to 10Gbps – depending on quality and type STP is more expensive since uses more materials, is less common, and required more expensive installation due to grounding High-grade UTP is priced similarly to mid-grade STP

TIA/EIA Twisted Pair Categories

TIA/EIA Twisted Pair Categories Contains four wire pairs Provides 10 Mbps throughput and 16 MHz bandwidth Limits segment length to 100 m (330 ft) Widely used in VoIP networks CAT4: Provides 10 Mbps throughput and 20 MHz bandwidth Carries better interference protection than CAT3 Both are replaced by newer UTP categories

TIA/EIA Twisted Pair Categories CAT4 (continued):

TIA/EIA Twisted Pair Categories Contains four wire pairs Provides 100 Mbps throughput and 100 MHz bandwidth Limits the length of each segment to 100 m (330 ft) Connects to a NIC via an RJ-45 connector Uses 118 twists per meter (3 per inch) on average Was produced in large quantities – still widely available Inexpensive, effective, popular

TIA/EIA Twisted Pair Categories CAT5 (continued):

TIA/EIA Twisted Pair Categories A version of CAT 5 cable with high-quality copper Contains four wire pairs Has higher twist ratios Incorporates better cross-talk reduction methods Provides 350 MHz bandwidth Allows 350/100 m segments at 100/1000 Mbps Inexpensive – widely used within 1 Gbps networks

TIA/EIA Twisted Pair Categories CAT5e (continued):

TIA/EIA Twisted Pair Categories Contains four wire pairs, each wrapped in foil insulation Additional insulation covers the bundle of four pairs Carries fire-resistant plastic sheath on the outside Resistant to crosstalk 250 MHz bandwidth provides up to 10 Gbps throughput Allows 100 m (300 ft) long or 37 m (120 ft) long segments (for up to 1 Gbps or 10 Gbps, respectively) Uses newer GG-45 connectors Widely used in modern 1 Gbps networks

TIA/EIA Twisted Pair Categories CAT6 (continued):

TIA/EIA Twisted Pair Categories CAT6 (continued):

TIA/EIA Twisted Pair Categories A higher-grade version of CAT6 cable Further reduces attenuation and crosstalk Allows longer segment lengths – up to 100 m at 10 Gbps Provides 550 MHz bandwidth Requires GG-45 connectors De Facto standard on modern networks

TIA/EIA Twisted Pair Categories CAT6e (continued):

TIA/EIA Twisted Pair Categories Contains increased amount of shielding Larger, heavier, less flexible Has 600 MHz bandwidth Provides 10 Gbps throughput on up to 100 m (330 ft) segment length, with large margin Requires GG-45 connectors De Facto standard on modern backbone networks CAT7a: In theory – 1 GHz, 40/100 Gbps at up to 50/15 m Currently under development

TIA/EIA Twisted Pair Categories CAT7 (continued):

TIA/EIA Twisted Pair Categories Cost: PCI Express NIC, single RJ-45 connector: $30–40 CAT6 50 ft patch cable: $10–12 Troubleshooting implies replacing cable

Twisted Pair Termination

Twisted Pair Termination Overview: Proper termination is required on both ends Poor termination leads to a data loss or a noise TP cable is automatically terminated when RJ-45 and GG-45 jacks are crimped onto it Two TIA/EIA standards exist for inserting the cable into jacks – 568A and 568B Any of the two standard can be used – the same one should be used on the entire network TP patch cable – sold in stores as premade, terminated, tested, and packaged cable

Twisted Pair Termination Termination (overview): Green Pair #3 – Transmit Orange Pair #2 – Transmit Orange Pair #2 – Receive Green Pair #3 – Receive

Twisted Pair Termination Straight-Through: Implies same TIA/EIA standard used on both ends Wires aren’t twisted end-to-end Used for connecting a PC to a hub or a switch Crossover: Implies using TIA/EIA 568A standard on one end and TIA/EIA 568B standard on another end Used for connecting two workstations or two network devices directly

Twisted Pair Termination Crossover (continued):

Making Twisted Pair Cables

Making Twisted Pair Cables Tools Needed: A wire cutter A wire stripper (removes the sheath) A crimping tool (fixes wires inside the connector) May come within same device Steps: Make a clean cut at both ends of wire using wire cutter Remove one inch of the sheath off of one end or wire Make sure to not to damage insulation

Making Twisted Pair Cables Steps (continued): Separate the pairs and unwind each pair for up to ½ inch Align the wires on a flat surface according to colors and positions Pull steadily across the unwound section of each wire (“groom” wires) Slide wires into their positions in the RJ-45 plug Place the RJ-45 plug in the crimping tool and press firmly avoiding any rotation Use tester to verify transmission over the wire made

Fiber Optic Cable

Fiber Optic Cable Layered Structure: Inner core – glass or plastic fibers at the center that carry laser pulses or an LED light used for data transmission Cladding – a layer of plastic or glass around the fibers that reflects the light back to the core Plastic buffer – an opaque layer that protects the cladding and the core and absorbs any light that escapes Strands of Kevlar – a polymeric fiber that surrounds the plastic buffer and prevents stretching and damaging Plastic sheath – providing the overall cable protection

Fiber Optic Cable Layered Structure (continued):

Fiber Optic Cable Single-Mode Fiber (SMF): Uses narrow core – less than 10 microns in diameter Propagates light without reflections – causes no dispersion and no significant energy loss Provides the highest bandwidth of all media and allows the longest distance without requiring repeaters Allows 60 km (37 mi) long segments at 10 Gbps Good for connecting large networks together The most expensive networking medium Suitable for WANs

Fiber Optic Cable Single-Mode Fiber (continued):

Fiber Optic Cable Multi-Mode Fiber (MMF): Uses wider core – from 50 to 115 microns in diameter, with 62.5 microns being most common size Multiple laser or LED pulses are sent over the fiber at different angles Allows 300 m (910 ft) long segments at 10 Gbps, 550 m (1670 ft) at 1 Gbps, and 2 km (6060 ft) at 100 Mbps Used for connecting network devices to a backbone Suitable for both LANs and WANs

Fiber Optic Cable SMF vs. MMF:

Fiber Optic Cable MMF vs. Copper, Advantages: Allows longest distances without requiring repeaters Much more resistant to noise Very secure – tapping into light transmissions isn’t easy MMF vs. Copper, Disadvantages: Installation and field repairs are much more complex for MMF (requires special equipment) Much more expensive MMF is used to provide much higher throughput – not anymore (CAT7 TP cable – up to 10 Gbps)

Fiber Optic Cable Characteristics: Highest throughput – no resistance allows achieving 100 Gbps per channel and reduces errors Highest cost – most expensive medium, NICs, and hubs, plus the highest installation costs – not practical for small networks Best EMI and noise immunity – no current used Size and scalability – segment length is limited by degradation of the signal (“optical loss”), with typical values from 150 to 40,000 meters (455 to 121,200 ft) Imperfections at connection points affect segment length

Fiber Optic Cable Connectors: Ten different types exist, with four being being most common – Straight Tip (ST), Standard Connector (SC), Local Connector (LC), and Mechanical Transfer Registered Jack (MT-RJ) All can be used for both SMF and MMF ST and SC are used on older networks LC and MT-RJ are smaller in size – allow higher density at termination points, used in newer networks MT-RJ connector contains two strands of fiber in a short protective tube (“ferrule”), allowing full-duplex mode

Fiber Optic Cable Connectors (continued): ST connector SC connector

Fiber Optic Cable Connectors (continued): LC connector MT-RJ connector

Fiber Optic Cable Connectors (continued):

Fiber Optic Cable Cost: PCI Express NIC, single LC connector: $500–600 MMF 50 ft cable, LC connecter: $50 – 60 Troubleshooting implies using professional services Installation time and labor costs are much higher than for TP cable

Homework Read the chapter and the summary section, then review the key terms learned Answer the review questions and verify your answers with the chapter or lecture slides Complete the case projects 3-1 and 3-3