Diagnostic Medical Sonography Program

Slides:



Advertisements
Similar presentations
DR. ahmed Abanamy hospital DOCTOR Nazih Mohammed Alothman Vascular Surgeon.
Advertisements

Detecting Pelvic Disease With Duplex Ultrasound Ron Bush, MD, FACS Midwest Vein & Laser Center Dayton, Ohio.
Resident Categorical Course
BASIC SCIENCE: ATHEROSCLEROSIS 2 February 2006 St Luke’s-Roosevelt Hospital Department of Surgery.
Venous Doppler Remains primary modality for assessing deep venous thrombosis of upper & lower extremities Diagnostic Criteria for DVT: Most reliable is.
Display of Motion & Doppler Ultrasound
Carotid duplex ultrasound
Paige Fabre It is important as professionals that we manage our patients effectively before, during and at the completion of our scans. When.
Carotid duplex ultrasound
Contents Vascular Technology Lecture 6
Vascular Diagnostic Testing Optimum Re Charlotte A. Lee, M.D., DBIM, FLMI.
Vascular ultrasound as diagnostic modalities for PAD
Date of download: 7/6/2016 Copyright © The American College of Cardiology. All rights reserved. From: Manifestations of Cardiac Disease in Carotid Duplex.
Interventional Procedures: lower extremities
Diagnostic Medical Sonography Program
Chapter 13 Evaluation of arterial bypass grafts and stents
Color Duplex Imaging Goals: Adjunct to physiologic testing
Diagnostic Medical Sonography Program
Diagnostic Medical Sonography Program
Current Problems in Diagnostic Radiology
Michael Siah, M.D. Medstar Georgetown University Hospital
Ultrasound evaluation of the RENAL ARTERIES and the kidney
The Winking Saphenous Vein Graft: Acute Aorto-Vein Graft Anastomotic Torsional Kink causing Dynamic Systolic Compression Complicating Vein Graft PCI Dr.
History : Case March 26, year old male patient with complaints of left calf pain (Typical Claudication) at rest and on exertion (Fontaine II/B).
The Role of Interventional Treatment for The Failing Grafts
Diagnostic Medical Sonography Program
Diagnostic Medical Sonography Program
Multimodality Imaging of Lower Extremity Peripheral Arterial Disease
Diagnostic Medical Sonography Program
Estimation of brachial artery volume flow by duplex ultrasound imaging predicts dialysis access maturation  Sae Hee Ko, MD, Dennis F. Bandyk, MD, Kelley.
Poiseuille’s Equation
Tibiotibial vein bypass grafts: A new operation for limb salvage
Diagnostic Medical Sonography Program
Diagnostic Medical Sonography Program
Lucy Stopher A/CNS Vascular Surgery
The value of 3D-CT angiographic assessment prior to carotid stenting
Brad L. Johnson, MD, Dennis F. Bandyk, MD, Martin R
Hemodynamics of vein graft stenosis
Diagnostic Medical Sonography Program Vascular Technology Lecture 6: Doppler Segmental Pressures of the Upper Extremities Holdorf.
Neovascularization in acute venous thrombosis
Can duplex scan arterial mapping replace contrast arteriography as the test of choice before infrainguinal revascularization?  Reese A. Wain, MD, George.
Diagnostic Medical Sonography Program Vascular Technology
Frank Pomposelli, MD  Journal of Vascular Surgery 
Arterial duplex for diagnosis of peripheral arterial emboli
Ted R. Kohler, M. D. , R. Eugene Zierler, M. D. , Robert L. Martin, B
Durability of the in situ saphenous vein arterial bypass: A comparison of primary and secondary patency  Dennis F. Bandyk, M.D., Hermann W. Kaebnick,
Diagnostic Medical Sonography Program Vascular Technology
Frank T. Padberg, MD, Joseph J. Rubelowsky, MD, Juan J
Turbulence occurring after carotid bifurcation endarterectomy: A harbinger of residual and recurrent carotid stenosis  Dennis F. Bandyk, M.D., Hermann.
Frequency of critical stenosis in primary arteriovenous fistulae before hemodialysis access: Should duplex ultrasound surveillance be the standard of.
Impact of a color-flow duplex surveillance program on infrainguinal vein graft patency: A five-year experience  Mirza M. Idu, MD, Jan D. Blankstein, MD,
The value of 3D-CT angiographic assessment prior to carotid stenting
Vascular complications of cardiac catheterization
Do normal early color-flow duplex surveillance examination results of infrainguinal vein grafts preclude the need for late graft revision?  Marc A. Passman,
Duplex-guided balloon angioplasty of failing or nonmaturing arterio-venous fistulae for hemodialysis: A new office-based procedure  Enrico Ascher, MD,
Diagnostic Medical Sonography Program
Extended study of aneurysm formation in umbilical vein grafts
Let IT FLOW Arterial Blood’s journey Normal and Abnormal Hemodynamics of the Arterial System hhholdorf.
Criteria for defining significant central vein stenosis with duplex ultrasound  Nicos Labropoulos, PhD, DIC, RVT, Marc Borge, MD, Kenneth Pierce, MD, Peter.
Balloon angioplasty for revision of failing lower extremity bypass grafts  Haitham Ali, MD, Ahmed Elbadawy, MD, Mahmoud Saleh, MD, Ayman Hasaballah, MD 
Intermittent claudication in a professional rugby player
Jon C. Bowersox, MD, PhD, Robert M. Zwolak, MD, PhD, Daniel B
Use of duplex scanning in the diagnosis of arteria profunda femoris stenosis  Andreas L. Strauss, MD, Willi Schäberle, MD, Horst Rieger, MD, Franz-Josef.
Duplex-guided balloon angioplasty and stenting for femoropopliteal arterial occlusive disease: An alternative in patients with renal insufficiency  Enrico.
The impact of color duplex surveillance on the outcome of lower limb bypass with segments of arm veins  R.T.A. Chalmers, MB, ChB, FRCS(Ed), J.J. Hoballah,
M.A. Bailey, V.P. Jagadesham, J.V. Patel, Y.J. Crow, D.J.A. Scott 
Vascular Surgery Michael Ricci, MD.
Ted R. Kohler, M. D. , Stephen C. Nicholls, M. D. , R
Hemodynamics of vein graft stenosis
Continuous – Wave Doppler
Presentation transcript:

Diagnostic Medical Sonography Program Lecture 12: Duplex Scanning and Color Flow Imaging of the Lower Extremities Holdorf

Duplex / Color Flow Imaging of the Lower Extremities Capabilities: Determines presence or absence of > 50% diameter reduction of occlusion Determines presence or absence of aneurysms Follow-up of bypass grafts To localize the stenotic lesion prior to balloon angioplasty

Limitations Presence of dressings, skin staples, sutures, open wounds Incisional tenderness, hematomas Obesity- may be difficult to image vessels Calcific shadowing from diabetes and or atherosclerosis

Patient Positioning Patient supine with head on pillow Extremity positioned close to the examiner Patient’s hip minimally rotated externally, with knee flexed Prone or lateral decubitus position may be required for assessment of popliteal artery

Physical Principles: the Doppler equation may be written as:

Df. =. Doppler shift frequency Fo. =. Carrier frequency c. = Df = Doppler shift frequency Fo = Carrier frequency c = Speed of ultrasound through soft tissue (1540m/sec) V = Velocity of the moving reflectors Cos 0 (theta) = Angle

Ideal Doppler angle for vascular exams is 60 degrees, obtained center-stream, parallel to walls. Vessel tortuosity and other conditions will cause the Doppler angle to be < 60 degrees, which IS usable. Not reliable: Doppler angle > than 60 degrees.

Technique: Native Arteries Scan with a 5 or 7 MHz linear array transducer for the following: Distal external iliac artery Common femoral artery (CFA) CFA bifurcation Superficial femoral artery (SFA) Profunda Femoris Superficial artery (proximal to distal) Popliteal artery (proximal to distal) Trifurcation Anterior tibial artery (ATA) Posterior tibial artery (PTA) Peroneal artery

Observe gray scale for plaque or other abnormalities Observe color flow patterns Obtain peak systolic velocities (PSV) from each major vessel (proximal, mid and distal if vessel is long) and more if disease suspected Characterize the Doppler signals: triphasic (normal). Biphasic, or monophasic (abnormal) Observe wave form for any spectral broadening

If a > 50% diameter reduction is suspected, obtain: If a > 50% diameter reduction is suspected, obtain: Pre-stenotic PSV (approaching the stenosis) PSV (highest) in stenosis

Post –Stenotic turbulence signals Document as previously described for UE

Technique: Bypass Grafts A. Know type, Location , and age: Synthetic (e.g. Gortex)

REVERSED SAPHANEOUS VEIN GRAFT (RSVG) Small end is now proximal * Large end is distal * Vein valves stay open due to arterial flow Pressure Branches are ligated * Size change often evident in the initial post-op study

Saphenous vein

In-Site Vein Graft GSV stays in place Small end is distal * Large end is proximal * Prior to surgery, valves broken up with special instrument; Branches ligated * Size change often evident in the initial post-op study

Technique Continued… B. Protocol usually combined with ABIs. C. Vein bypass graft evaluation includes: Observation of gray scale, color flow, and PSVs of the following: Inflow artery Proximal Anastomosis Entire Length of the vein bypass graft Distal Anastomosis Outflow artery Also check for branches (that could form AV Fistulas), valves, and or other abnormalities

Technique continued… D. Synthetic bypass graft evaluation include observations of gray scale, color image, PSVs of the following: Inflow artery Proximal anastomosis Mid Graft Distal anastomosis Outflow artery

Interpretation: Native Arteries A. Normal Doppler signals are triphasic; a change to biphasic can be significant: however, some patients normally have biphasic flow without evidence of disease

B. Abnormal findings Compare stenotic PSV to Pre-Stenotic PSV 2:1 ratio = > 50% diameter reduction 4:1 ratio = > 75% diameter reduction >400 cm/sec PSV = > 75% diameter reduction Never accept the value of numbers alone; post-stenotic turbulence should be present Observe for occlusions and aneurysms

Pre-stenotic Doppler spectra demonstrates a waveform that is Monophasic Dampened Doppler spectra obtained AT the stenosis Documents the highest PSVs Post-Stenotic Doppler spectra demonstrates a waveform that shows turbulence (Usually distal to a > 50% stenosis

Interpretation: Bypass Grafts A. Normal: Lower resistance flow patterns may normally be expected. Some retrograde flow in the native artery may be evident at the distal anastomosis of a Reversed Saphenous Vein Graft (RSVG), which provides an additional source of collateral flow. (Retrograde flow results from a pressure gradient)

B. Abnormal Findings Compare results with previous studies and observe for changes such as: Decrease of 30 cm/sec in any graft segment Reduced PSVs in smallest graft diameter that were greater previously Change from Triphasic to biphasic signals Decrease in ABI of > .15 Observe for post-complications such as: AV fistula (can siphon off graft flow); valve cusp Can also apply previous data used for native artery stenosis

C. Synthetic Grafts Can loosely apply the previous data to determine whether a > 50% diameter reduction exists. Anastomotic sites should be evaluated well for aneurysm and or stenosis Observe for graft occlusion

Synthetic LE Bypass grafts

Post Endovascular Intervention In general, normal stented arteries may have elevated peak systolic velocities Greatly elevated peak systolic velocities are abnormal and suggest a hemodynamically significant diameter reduction

Intraoperative monitoring Used for checking patency of anastomotic sites Evaluate any suspicious stenotic or turbulent areas that can occur in vein bypass grafts (e.g., valve cusp sites or suspected branch sites) Use highest frequency imaging transducer available

Additional Notes Lecture 12 Duplex / Color flow imaging (LE)   Calculating for velocity is the only thing that we do not know. Calculation is based on your angle. Doppler angle of greater than 60 degrees is not good

Bypass grafts For In-situ Vein Graft, will use as an artery All braches must be ligated. Now arterial. For synthetic bypass graft Looking at prox and distal ends.

Pay close attention to the ratios 2:1 4:1 difference is bad.   Telling the story Systole: Proximal issues Diastole: distal issues. Blood flows because of a pressure gradient. High to low pressure.

Interpretation of bypass grafts Normal splash of blue color in systole (reversal) is normal due to mixed pressure gradient.   If Velocity 1 (study one) showed a peak systolic Velocity PSV of .89 and the second study shows a PSV of 5.56, then this is a greater than 4:1 ratio, which is bad. AV fistula: two things are connected that normally would not be.

Homework Chapter 13: Pages 127-138 SDMS assignments