Acoustic Emission Sensing for Chemical Mechanical Polishing (CMP)

Slides:



Advertisements
Similar presentations
Effects of Pad Properties on Cu Dishing During CMP Caprice Gray PhD Student, Mechanical Engineering Tufts University, Medford, MA Intel Intern Presentation.
Advertisements

TRMM Tropical Rainfall Measurement (Mission). Why TRMM? n Tropical Rainfall Measuring Mission (TRMM) is a joint US-Japan study initiated in 1997 to study.
October 13, 2006 Kyushu Institute of Technology Kyushu Institute of Technology Prof. Keiichi Kimura Keiichi Kimura, Katsuya Nagayama, Yosuke Inatsu, Panart.
Kay Graf Physics Institute 1 University of Erlangen ARENA 2006 University of Northumbria June 28 – 30, 2006 Integration of Acoustic Neutrino Detection.
Instantaneous Fluid Film Imaging in Chemical Mechanical Planarization Daniel Apone, Caprice Gray, Chris Rogers, Vincent P. Manno, Chris Barns, Mansour.
1 Localized surface plasmon resonance of optically coupled metal particles Takumi Sannomiya*, Christian Hafner**, Janos Vörös* * Laboratory of Biosensors.
Kay Graf Physics Institute University of Erlangen TeV Particle Astrophysics II Madison, WI, USA August 28 – 31, 2006 Towards Acoustic Detection of UHE.
CMP FtF 9 Nov 06 Friction Updates 1.Last FtF Past issues & solutions 2.Latest data CoF vs. slurry dilution CoF vs. rotation rate Fz vs. slurry dilution.
Impact of Nanotopography on STI CMP in Future Technologies D. Boning and B. Lee, MIT N. Poduje, ADE Corp. J. Valley, ADE Phase-Shift W. Baylies, Baytech.
Time Series Analysis of Elephant Acoustic and Seismic Signals Alex Williamson Physics Dept.
CMP C M P HEMICAL ECHANICAL LANARIZATION.
8:30 – 9:00Research and Educational Objectives / Spanos 9:00 – 9:45 CMP / Doyle, Dornfeld, Talbot, Spanos 9:45 – 10:30 Plasma & Diffusion / Graves, Lieberman,
Andrew Jacquier Brigham Young University
Principal Investigator: Chris Rogers
Development of Slurries for Polishing SiLK TM -Integrated Wafers Dr. David Merricks IITC 2003 Acknowledgements to Bob Her, David Tysiac, Sheldon Mao, Lynn.
CMP C hemical M echanical P lanarization Carried out by Eran Cantrell, Bobby O’Ryan, And Maximus (CMP)
Seminar ON SMART SENSOR Submitted by : SUBIR KUMAR GHOSH Roll No. IN-14/04 Electrical & Instrumentation Deptt. B.E 7th Semester JORHAT ENGINEERING COLLEGE,
FEMTOSECOND LASER FABRICATION OF MICRO/NANO-STRUCTURES FOR CHEMICAL SENSING AND DETECTION Student: Yukun Han MAE Department Faculty Advisors: Dr. Hai-Lung.
The Effect of Wafer Shape in Chemical Mechanical Planarization Researcher: Joseph Lu Principal Investigator: Chris Rogers Corporate Sponsors: Cabot Corporation.
Feasibility of 3-D Surface Machining by Dry EDM 1/15 班級 : 碩研奈米一甲 學號 :M98R0105 報告者:陳致維 報告日期: 06/04/2010.
11/8/ Chemical Aspects of CMP SFR Workshop November 8, 2000 Tanuja Gopal and Prof. Jan Talbot UC San Diego La Jolla, CA 2001 GOAL: Build integrated.
INSTANTANEOUS IN-SITU IMAGING OF SLURRY FILM THICKNESS DURING CMP Caprice Gray, Daniel Apone, Chris Rogers, Vincent P. Manno, Chris Barns, Mansour Moinpour,
MIT Lincoln Laboratory NU Status-1 JAB 11/20/2015 Advanced Photodiode Development 7 April, 2000 James A. Burns ll.mit.edu.
Fixed Abrasive Design for Chemical Mechanical Polishing
11/8/ Microplasma Optical Emission Spectrometer (MOES) on a chip SFR Workshop November 8, 2000 Michiel Krüger, David Hsu, Scott Eitapence, K. Poolla,
Pad Characterization Update Caprice Gray Nov. 9, 2006 Cabot Microelectronics Aurora, IL.
Brizon Inc Products: Microelectronic Application CMP Slurry additive CMP cleaning solutions Wafer storage buffer solution.
Haga clic para modificar el estilo de texto del patrón Infrared transparent detectors Manuel Lozano G. Pellegrini, E. Cabruja, D. Bassignana, CNM (CSIC)
Feature-level Compensation & Control F LCC CMP April 5, 2006 A UC Discovery Project.
Chemical Techniques and Developments Mechanical Planarization.
Andrew Chang, David Dornfeld
5/24/ Towards a Complete Plasma Diagnostic System SFR Workshop May 24, 2001 Dong Wu Zhao, Costas Spanos Berkeley, CA 2001 GOAL: Install automated.
Acoustic and Thermal Methods in Detecting Endpoint during Chemical Mechanical Polishing of Metal Overlay for Nanoscale Integrated Circuits Manufacturing.
Charge Multiplication Properties in Highly Irradiated Thin Epitaxial Silicon Diodes Jörn Lange, Julian Becker, Eckhart Fretwurst, Robert Klanner, Gunnar.
EE235 Nanofabrication Technology Multifunctional Nanowire Evanescent Optical Sensors By By Donald J. Sirbuly, Andrea Tao, Matt Law, Rong Fan, and Peidong.
Tests performed on By Corporate Marketing Department - Tecniplast, Buguggiate -
ARENA08 Roma June 2008 Francesco Simeone (Francesco Simeone INFN Roma) Beam-forming and matched filter techniques.
Colloidal Silica, Ceria Slurry의 Particle 규명 및 제어 방법 연구
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
June 2013 Acoustic Emission as Toll for Identifying the Drill Position in Fiber Reinforced Plastic and Aluminum Stack Dr. Uri Ben-Hanan, ORT Braude College,
Don State Technical University Department “Machine Building" 7/6/2016.
Detection of Perfluorinated Compounds By High-Pressure Microplasma Optical Emission Spectroscopy SFR Workshop November 8, 2000 David Hsu, Michiel Krüger,
On Wafer Ion Flux Sensors
Shear Actuation of Piezoelectric Transducers for Ultrasonic Evaluation of Adhesive Joints Hussain Altammar Mechanical Engineering Department, University.
Brian Tang and Duane Boning MIT Microsystems Technology Laboratories
Robert Lahmann VLVnT – Toulon – 24-April-2008
T. Eberl for Robert Lahmann and the Erlangen acoustic group
Overview of AMADEUS and Positioning for KM3NeT
Robotics Sensors and Vision
Presented By Tom Spenceley & Jerry Bauer
Electron-Beam Machining
Andrew Chang, David Dornfeld
3rd Annual SFR Workshop, November 8, 2000
Section 9: CMP EE143 – Ali Javey.
Layer Transfer Using Plasma Processing for SMART-Wafer
Enabling Full Profile CMP Metrology and Modeling
Is Co-existence Possible?
Microsensors for Monitoring Wafer Uniformity of Plasma Processes
Development of Lithium Batteries for Powering Sensor Arrays
Instabilities in Electronegative Inductive Discharges
Instabilities in Inductive Discharges
Layer Transfer Technology for Micro-System Integration
Scratch Testing of Silicon Wafers for Surface Characterization
Jianfeng Luo, Prof. David Dornfeld
Junwei Bao, Costas Spanos
Yaoxi Wu and M. A. Lieberman
Jianfeng Luo and David A. Dornfeld
Full Profile CMP Metrology
Jianfeng Luo, David Dornfeld
Role of Glycine in Chemical Mechanical Planarization (CMP) of Copper
Presentation transcript:

Acoustic Emission Sensing for Chemical Mechanical Polishing (CMP) SFR Workshop November 8, 1999 Andrew K. Chang and David A. Dornfeld Berkeley, CA This work aims to investigate the feasibility of using acoustic emission to study the mechanical aspects of the material removal mechanism in CMP. 4/16/2019

Acoustic Emission Process Monitoring Pad condition monitoring End Point Detection (EPD) - Acoustic signature of material removal changes when polishing different materials Scratch Detection – Catastrophic scratching of the wafer surface caused by impurities embedded in the pad surface can be detected. Acoustic Emission Sources in CMP 4/16/2019

AE Ratio Signal Processing AE Ratios—A signal processing scheme that separates the raw signal into high and low band-pass regimes. During each sampling period (Dt), an average signal level (ASL) calculation is performed, and the ratio of the two peak values is calculated. HFpeak LFpeak ASL Dt High Pass Filter >100 kHz Ratio = Low Pass Filter 20-60 kHz Raw AE Signal AE Sensor 4/16/2019

Experimental Setup Sensor Integration – A laboratory-scale cmp machine was modified to attach the AE sensor on the backside of the wafer. 4/16/2019

ASL Ratio Sampling Period (Dt) Experimental Setup Workpiece Bare Silicon Wafer PSG Oxide Wafer Slurry De-ionized Water Nalco 2352 (particle size 70-90 nm) Polishing Pad IC 60 Linear Velocity 50 – 141 mm/sec ASL Ratio Sampling Period (Dt) 10 ms Sampling Duration 20 sec 4/16/2019

Results AE data obtained from polishing in the absence of abrasive particles. “Air polish” data point represents background level “noise” of environment without contact between pad and wafer Bare and Oxide Wafers Polished with Slurry 3.0 2.5 Average HF/LF Ratio 2.0 Air Polish 1.5 Bare Wafer Oxide Wafer 1.0 20 40 60 80 100 120 140 160 Linear Velocity (mm/s) 4/16/2019

Results AE data differentiating between polishing with (Nalco slurry) and without (DI Water) abrasive particle slurry. 20 40 60 80 100 120 140 160 1.0 1.5 2.0 2.5 3.0 Air Polish Bare Wafer Polished with Slurry and DI Water Wafer 1 with Slurry Wafer 2 with Slurry Wafer 2 with DI Water Average HF/LF Ratio Linear Velocity (mm/s) 4/16/2019

Progress vs Milestones Process Monitoring Year 1 Develop Acoustic Emission sensing for CMP. (Done) Year 2 Evaluate Acoustic Emission sensing for pad degradation, micro-scratching, and end-pointing for multi-layer stacks. (On-going) 4/16/2019

Future Work During the 2000-2002 period, we will extend the evaluation of the use of acoustic emission as applied to: AE Ratio sensitivity to CMP operating conditions Pad Type Slurry Type Pressure Correlation of AE to CMP material removal mechanism, multi-stack polishing, metal polishing Development of endpoint detection methodology 4/16/2019