ABB i-bus® EIB / KNX Application Unit Time ABZ/S 2.1

Slides:



Advertisements
Similar presentations
Cinnamon Cove Computer Club UPDATING ACTIVE HOME.
Advertisements

© 2004 Cisco Systems, Inc. All rights reserved. Operating and Configuring Cisco IOS Devices Starting a Switch INTRO v2.0—8-1.
Factoring General Trinomials Factoring Trinomials Factors of 9 are: REVIEW: 1, 93, 3.
Introduction to Engineering Camera Lab #4 – 3 Task #2 Agenda Review Task #2 procedure Conduct Task #2 Work on lab report.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
HDL KNX System Introduction
Embedded Programming and Robotics Lesson 11 Arduino Interrupts 1.
ABB i-bus® EIB Shutter Actuators
Fan Coil Actuator FCA/S 1.x.x.2
Frequently Asked Questions (FAQ)
ABB STOTZ-KONTAKT GmbH Intrusion Detection Technology SSM/x SafeKey Switching Module 2011 | Slide 1.
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Weather Unit, Weather Sensor
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX i-bus® Tool
ABB i-bus® KNX Application Unit Logic ABL/S 2.1
DALI-Gateway DG/S 1.1.
ABB STOTZ-KONTAKT GmbH DALI-Gateway DG/S
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.

Room Controller RC/A 8.1 Room Controller economic flexible modular.
Intelligent building system EIB IP-Gateway
automatic recognition of load-type superior functionality
2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX ISx/S 5.1 IP Switch Master and Slave IPM/S 1.1 IP Patch Module © STO/G - Slide 1.
DALI-Gateway DG/S 8.1.
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Line Coupler LK/S4.2
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
ABB i-bus® KNX Valve Drive Actuator VAA/A
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
ABB i-bus® KNX Diagnosis and Protection Module DSM/S 1.1
Blower-/Fan Coil-Actuator
Universal Interface, 4-fold, FM, US/U 4.2
ABB i-bus® EIB Display and Control Tableau
Lesson Objectives Aims Key Words Interrupt, Buffer, Priority, Stack
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
ABB i-bus® KNX Weather Unit , Weather Sensor
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
Zone Terminal MT/U Technical Overview
UNIT – Microcontroller.
HDL KNX NetIP Module M/IPIF.1 /M/IPRT.1.
with UCM/KNX Rev Sept 2010 Ref: UCM/KNX Manual
DMX512 Gateway M/DMX512.1.
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
DIGITAL CALCULATOR USING 8051
ABB i-bus® KNX IP Interface IPS/S 2.1 IP Router IPR/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Time Switch FW/S 8.2.1
Security Module, MDRC SCM/S 1.1
ABB i-bus® EIB / KNX Elektromotor Valve Drive ST/K 1.1
Jörn Kruse / STO-G / ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Brightness Sensor Interface HS/S © STO/G - Slide 1.
RS 232- interface 2fold, MDRC EA/S 232.5
ABB STOTZ-KONTAKT GmbH
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
ABB i-bus® KNX Logic Controller ABA/S 1.2.1
ABB i-bus® EIB / KNX Fault Monitoring Unit SMB/S 1.1
ABB i-bus® EIB / KNX USB Interface
ABB i-bus® KNX Phase Busbar PS 1/x/6-KNX.
EIB Power Supply, 160 mA SV/S
Commissioning Power Supply NTI/Z
Universal I/O Concentrator UK/S 32.2
ABB i-bus® EIB Logic Module LM/S 1.1
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
ECEG-3202 Computer Architecture and Organization
ABB i-bus® KNX The new I/O-Actuators IO/S and IO/S
ABB i-bus® EIB / KNX EIB Monitoring Unit EUB/S 1.1
COMPUTER PERIPHERALS AND INTERFACES
Universal Dim Actuator UD/S
ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1
Buttons.
Presentation transcript:

ABB i-bus® EIB / KNX Application Unit Time ABZ/S 2.1

Product overview ABZ/S 2.1 Application Unit Time, MDRC (2 MW) Order code 2CDG 110 072 R0011 Programming button / LED Bus connection terminal Product overview / Device technology / Application / Terms

Device technolo gy ABZ/S 2.1 Successor of AB/S 1.1 with application Time Groups1 Parametrisation software PZM2 Application program Time Groups2 The appearance of the software is the identical with AB/S 1.1 Converting of „old“ applications of an existing project possible Software only for the ETS3 Product overview / Device technology / Application / Terms

Application ABZ/S 2.1 Multi channel timer with Time program Groups Yearly program, week- and day routines Daylight saving time an special days Groups with members and trigger Time program 15 day routines with 800 switching times 100 special days, 10(5) years of daylight saving times in advance Groups 30(20) groups with 300 members Product overview / Device technology / Application / Terms

Terms ABZ/S 2.1 Time switching program Defines when bus telegrams with specific group addresses and specific values are sent on the bus. Day routine Contains the time switch program for a the between 00:00 ... 23:59 clock. Day routines can be activated and deactivated by the time switch program and bus telegrams. Product overview / Device technology / Application / Terms

Terms ABZ/S 2.1 Week routine Defines the assignment of the day routines to the day of the week. Special day Individual days and periods that deviate from the normal week. Product overview / Device technology / Application / Terms

Terms ABZ/S 2.1 Group „Functional group“ is a combination of group addresses which are sent at the same time. Group members Group addresses that belong to a group. Product overview / Device technology / Application / Terms

Terms ABZ/S 2.1 Group trigger Group addresses which trigger a functional group. The type and value of the trigger group address influences the group function. „0“ switches ON, „1“ switches OFF Value < 230 switches ON, value > 250 switches OFF The behaviour on bus failure (read value or use initial value) can be selected. Product overview / Device technology / Application / Terms