Endovascular repair of thoracic stent-graft bulging rupture in a patient with multiple thoracic aneurysms due to Takayasu disease  Guido Regina, MD, Alessandro.

Slides:



Advertisements
Similar presentations
Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for intervention  Greg.
Advertisements

Annual rupture risk of abdominal aortic aneurysm enlargement without detectable endoleak after endovascular abdominal aortic repair  Dave Koole, MD, Frans.
Albert C. W. Ting, MS, FRCS, Stephen W. K
The value of the initial post-EVAR computed tomography angiography scan in predicting future secondary procedures using the Powerlink stent graft  Mitul.
Mark J.W. Koelemay, MD, PhD  Journal of Vascular Surgery 
International controlled clinical trial of thoracic endovascular aneurysm repair with the Zenith TX2 endovascular graft: 1-year results  Jon S. Matsumura,
The chimney procedure is an emergently available endovascular solution for visceral aortic aneurysm rupture  Felix J.V. Schlösser, MD, PhD, John E. Aruny,
Significant sac retraction after endovascular aneurysm repair is a robust indicator of durable treatment success  Rabih Houbballah, MD, Marek Majewski,
Acute blunt traumatic injury to the descending thoracic aorta
Surgeon-modified fenestrated-branched stent grafts to treat emergently ruptured and symptomatic complex aortic aneurysms in high-risk patients  Joseph.
Acute bilateral renal artery chimney stent thrombosis after endovascular repair of a juxtarenal abdominal aortic aneurysm  Salvatore T. Scali, MD, Robert.
Totally videoendoscopic descending thoracic aorta-to-femoral artery bypass  Sumio Fukui, MD, Nikolaos Paraskevas, MD, Patrick Soury, MD, Frédéric Gigou,
Thoracic aortic lesions treated with the Zenith TX1 and TX2 thoracic devices: Intermediate- and long-term outcomes  Jose P. Morales, MD, Roy K. Greenberg,
Randall R. De Martino, MD, MS, Jill Johnstone, MD, Elizabeth A
A comparison between contrast-enhanced ultrasound imaging and multislice computed tomography in detecting and classifying endoleaks in the follow-up after.
Endovascular repair of descending thoracic aortic aneurysm in patient with Wiskott- Aldrich syndrome  Ragai Reda Makar, MSc, MD, FRCS, Pavels Gordins,
Aortoduodenal fistula 5 years after endovascular abdominal aortic aneurysm repair with the Ancure stent graft  Blaine J. Ruby, MD, Thomas H. Cogbill,
Visceral vessel relocation techniques
Combined surgical and endovascular treatment of aortic arch aneurysms
Thoracic endografting in a patient with hereditary hemorrhagic telangiectasia presenting with a descending thoracic aneurysm  Nicholas D. Andersen, MD,
Endovascular treatment of contained rupture of a superior mesenteric artery aneurysm resulting from neurofibromatosis type I  Célio Teixeira Mendonça,
Hybrid treatment of an ascending aortic pseudoaneurysm following multiple sternotomies  Vito Giovanni Ruggieri, MD, Romain Malezieux, MD, Najeebullah.
John W. Fehrenbacher, MD, Robert A. McCready, MD 
Early versus late experience in fenestrated endovascular repair for abdominal aortic aneurysm  Magnus Sveinsson, MD, Jonathan Sobocinski, MD, PhD, Timothy.
Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for intervention  Greg.
Late Gore Excluder endoprosthesis fabric tear leading to abdominal aortic aneurysm rupture 5 years after initial implant  Anand Dayama, MD, Nikolaos Tsilimparis,
Safety and effectiveness of the INCRAFT AAA Stent Graft for endovascular repair of abdominal aortic aneurysms  Giovanni Torsello, MD, Dierk Scheinert,
Bruce A. Perler, MD, MBA  Journal of Vascular Surgery 
Staged endovascular stent grafts for concurrent mobile/ulcerated thrombi of thoracic and abdominal aorta causing recurrent spontaneous distal embolization 
What is the clinical utility of a 6-month computed tomography in the follow-up of endovascular aneurysm repair patients?  Michael R. Go, MD, Joel E. Barbato,
Endovascular stent graft for symptomatic mobile thrombus of the thoracic aorta  Philipp Fueglistaler, MD, Thomas Wolff, MD, Lorenz Guerke, MD, Peter Stierli,
Outcomes of endovascular treatment for aortic pseudoaneurysm in Behcet's disease  Sung Won Kim, MD, Do Yun Lee, MD, Man Deuk Kim, MD, Jong Yun Won, MD,
Gary R. Seabrook, MD  Journal of Vascular Surgery 
Therapeutic management of superior mesenteric artery aneurysms
Thoracic endovascular aortic repair of aortobronchial fistulas
Bronchoesophageal fistula after endovascular repair of ruptured aneurysm of the descending thoracic aorta  Luigi Bonavina, MD, Tommaso Lupattelli, MD,
Infected aneurysm of the thoracic aorta
Endovascular treatment of a tuberculous infected aneurysm of the descending thoracic aorta: A word of caution  Louis Labrousse, MD, Michel Montaudon,
The results of stent graft versus medication therapy for chronic type B dissection  Xin Jia, MD, Wei Guo, MD, Tian-xiao Li, MD, Sheng Guan, MD, Rui-min.
Endovascular repair of an iliac artery aneurysm in a patient with Ehlers-Danlos syndrome type IV  Britt H. Tonnessen, MD, W. Charles Sternbergh, MD, Krishna.
Endovascular treatment of the descending thoracic aorta in a patient with a hydatid pseudoaneurysm  Pierro Volpe, MD, Ilias Dalainas, MD, PhD, Maurizio.
Simon Schwill, Scott A. LeMaire, MD, Susan Y. Green, MPH, Faisal G
Endotension after endovascular treatment of abdominal aortic aneurysm: Percutaneous treatment  Marie Cerna, MD, PhD, Martin Köcher, MD, PhD, Petr Utikal,
Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture  Bart E. Muhs, MD,
Urgent endovascular repair for ruptured aortic aneurysm using computed tomography image fusion  Vincent Ziza, MD, Frédéric Cochennec, MD, Pascal Desgranges,
Richard E. Parsons, MD, Michael L. Marin, MD, Frank J
Real chimney technique for total debranching of supra-aortic trunks
Karthikeshwar Kasirajan, MD, Mark D. Morasch, MD, Michel S
Coil embolization of persistent false lumen after stent graft repair of type B aortic dissection  Enrique María San Norberto, MD, Vicente Manuel Gutiérrez,
Thoraflex Hybrid Endovascular Frozen Elephant Trunk Device for Treatment of Complex Aortic Arch Disease  John H. Landau, Luc A. Dubois, Adam H. Power,
The role of aortic stent grafting in the treatment of atheromatous embolization syndrome: Results after a mean of 15 months follow-up  Alfio Carroccio,
Evaluation of the Endurant stent graft under instructions for use vs off-label conditions for endovascular aortic aneurysm repair  Giovanni Torsello,
David H. Stone, MD, David C. Brewster, MD, Christopher J
Sideways displacement of the endograft within the aneurysm sac is associated with late adverse events after endovascular aneurysm repair  Evert J. Waasdorp,
Eight-year follow-up of endovascular repair of a brachiocephalic trunk aneurysm due to Takayasu's arteritis  Domenico Angiletta, MD, Davide Marinazzo,
Total debranching thoracic endovascular aortic arch repair with inflow from the descending thoracic aorta  Yasunori Iida, MD, PhD, Tsutomu Ito, MD, PhD,
Aortic type B dissection with acute expansion of iliac artery aneurysm in previous endovascular repair with iliac branched graft  Raffaele Pulli, MD,
Endovascular management of thoracic aortic aneurysms
Supra-aortic hybrid endovascular procedures for complex thoracic aortic disease: Single center early to midterm results  Yiu Che Chan, BSc MB, BS, MD,
The frozen elephant trunk: An interesting hybrid endovascular-surgical technique to treat complex pathologies of the thoracic aorta  Florian S. Schoenhoff,
P Jetty, MD, G.G Barber, MD  Journal of Vascular Surgery 
Endovascular repair of a penetrating thoracic aortic ulcer by way of the carotid artery  Michael J Heidenreich, MD, David G Neschis, MD, Michael J Costanza,
Feasibility of the Inoue single-branched stent-graft implantation for thoracic aortic aneurysm or dissection involving the left subclavian artery: Short-
Sukgu M. Han, MD, Warren J. Gasper, MD, Timothy A.M. Chuter, MD 
Are intrasac pressure measurements useful after endovascular repair of abdominal aortic aneurysms?  Ross Milner, MD, Paola De Rango, MD, Fabio Verzini,
Robert J. Hinchliffe, MD, MRCS, Janet T
Repair of juxtarenal para-anastomotic aortic aneurysms after previous open repair with fenestrated and branched endovascular stent grafts  Donald J. Adam,
Surgical versus endovascular repair by iliac branch device of aneurysms involving the iliac bifurcation  Konstantinos P. Donas, MD, PhD, Giovanni Torsello,
Michael P. Jenkins, MD, Stéphan Haulon, MD, PhD, Roy K
Open repair of abdominal aortic aneurysm in a centenarian
Presentation transcript:

Endovascular repair of thoracic stent-graft bulging rupture in a patient with multiple thoracic aneurysms due to Takayasu disease  Guido Regina, MD, Alessandro Bortone, MD, Giovanni Impedovo, MD, Emanuela De Cillis, MD, Domenico Angiletta, MD, Vincenzo Marotta, MD  Journal of Vascular Surgery  Volume 45, Issue 2, Pages 391-394 (February 2007) DOI: 10.1016/j.jvs.2006.10.001 Copyright © 2007 The Society for Vascular Surgery Terms and Conditions

Fig 1 Connecting bar fracture of the Excluder device with a mild enlargement of thoracic aorta due to the device bulging. Journal of Vascular Surgery 2007 45, 391-394DOI: (10.1016/j.jvs.2006.10.001) Copyright © 2007 The Society for Vascular Surgery Terms and Conditions

Fig 2 Angiographic-computed tomography scan: severe enlargement of the descending thoracic aorta (70 mm), bulging rupture of Excluder stent graft, and presence of two small aneurysms near the distal implantation site. Journal of Vascular Surgery 2007 45, 391-394DOI: (10.1016/j.jvs.2006.10.001) Copyright © 2007 The Society for Vascular Surgery Terms and Conditions

Fig 3 Angiographic-computed tomography scan: severe enlargement of the descending thoracic aorta (70 mm), bulging rupture of Excluder stent graft, and presence of two small aneurysms near the distal implantation site. Journal of Vascular Surgery 2007 45, 391-394DOI: (10.1016/j.jvs.2006.10.001) Copyright © 2007 The Society for Vascular Surgery Terms and Conditions

Fig 4 Telescope-fashion implantation of a new endovascular device, with complete exclusion of the thoracic aneurysm and of the small distal ones without any evidence of endoleaks or dislodgement. Journal of Vascular Surgery 2007 45, 391-394DOI: (10.1016/j.jvs.2006.10.001) Copyright © 2007 The Society for Vascular Surgery Terms and Conditions

Fig 5 3D Angiographic CT scan: complete exclusion of the aneurysms with the implantation of a new graft inside the previous graft. Journal of Vascular Surgery 2007 45, 391-394DOI: (10.1016/j.jvs.2006.10.001) Copyright © 2007 The Society for Vascular Surgery Terms and Conditions