ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1

Slides:



Advertisements
Similar presentations
In this presentation you will:
Advertisements

Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
1 Intelligent Lighting Solutions for Professionals.
Basic Equipment and Schematic Reading. Objectives Learn the basic equipment that will be used in the Lab. Learn some of the basic symbols used on electrical.
PART1 Data collection methodology and NM paradigms 1.
ABB i-bus® EIB Shutter Actuators
ABB i-bus® KNX Fan Coil Actuator FCA/S
Fan Coil Actuator FCA/S 1.x.x.2
ABB STOTZ-KONTAKT GmbH Intrusion Detection Technology SSM/x SafeKey Switching Module 2011 | Slide 1.
Fan Coil Controller FC/S 1.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Weather Unit, Weather Sensor
G. Schlag / STO-GM / Novembre 2012
DALI-Gateway DG/S 1.1.
ABB STOTZ-KONTAKT GmbH DALI-Gateway DG/S
Wireless Power Interface
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
Room Controller RC/A 8.1 Room Controller economic flexible modular.
automatic recognition of load-type superior functionality
DALI-Gateway DG/S 8.1.
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Line Coupler LK/S4.2
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
ABB i-bus® KNX Weather Station
ABB i-bus® KNX Valve Drive Actuator VAA/A
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
ABB i-bus® KNX Room Solutions
Blower-/Fan Coil-Actuator
Universal Interface, 4-fold, FM, US/U 4.2
ABB i-bus® EIB Display and Control Tableau
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
ABB i-bus® KNX Weather Unit , Weather Sensor
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Telephone Gateway TG/S 3.2
ABB i-bus® EIB Electronic Switch Actuator, 4-fold
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
Wireless 4 Buttons Touch Panel
What is meant by ‘Preventive Monitoring’?
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
Wireless 3 Buttons Touch Panel
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Time Switch FW/S 8.2.1
Security Module, MDRC SCM/S 1.1
Jörn Kruse / STO-G / Mai 2009 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX The „smaller“ Room Controller RC/A 4.2 © STO/G - Slide 1.
ABB i-bus® EIB / KNX Elektromotor Valve Drive ST/K 1.1
Jörn Kruse / STO-G / ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Brightness Sensor Interface HS/S © STO/G - Slide 1.
RS 232- interface 2fold, MDRC EA/S 232.5
Grid feeding monitoring relay
ABB STOTZ-KONTAKT GmbH
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
Automatic Generation Control (AGC)
ABB i-bus® EIB / KNX Fault Monitoring Unit SMB/S 1.1
ABB i-bus® EIB / KNX USB Interface
4 channels, each as input or output
2 channels, each as input or output
EIB Power Supply, 160 mA SV/S
Commissioning Power Supply NTI/Z
Universal Interface, 12-fold, FM US/U 12.2
Universal I/O Concentrator UK/S 32.2
ABB i-bus® EIB Logic Module LM/S 1.1
ABB i-bus® KNX Analogue Input
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
ABB i-bus® EIB / KNX EIB Monitoring Unit EUB/S 1.1
Network Topologies & Standards
Universal Dim Actuator UD/S
Part of Chapter 1 Key Concepts Networks
Welcome to Cse490ra - Tablet PC Independent Study Course
AM-7027 Up Converter-Amplifier
ABB i-bus® EIB / KNX Application Unit Time ABZ/S 2.1
The efficient interface for lighting control
Presentation transcript:

ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1

Product overview BDB/S 1.1 Data Logging Unit, MDRC (2 MW) Order code 2CDG 110 072 R0011 Programming button / LED Bus connection terminal Product overview / Device technology / Application

Device technology BDB/S 1.1 35 channels available Detection of operating hours and switching operations per channel Programming of channels All channels together or Each channel individually Operating hour telegrams can be sent cyclically or after change Switching operation telegrams can be sent cyclically Product overview / Device technology / Application

Data Logging Unit BDB/S 1.1 Bus voltage failure All values (operating hours, switching operations, initial values and thresholds) will be stored continuously Bus voltage recovery Values will be restored automatically In case of exceeding of thresholds correct telegrams will be transmitted on ABB i-bus® Product overview / Device technology / Application

Device technology BDB/S 1.1 Cyclical polling of switching status Read-Flag at the dedicated communication object must be active In case of no response the polling telegram will be repeated twice For a better overview each channel can be described with a text E.g. 1st floor lamp 1or office no.12 E.g. pump AC Product overview / Device technology / Application

Device technology BDB/S 1.1 Operating time Detection per channel in seconds Output telegram in hours Each action ON, OFF ON and OFF increases the operating hour counter Counted and initial values, thresholds can be changed via bus Stored values, remaining- and initial values can be overwritten by download Product overview / Device technology / Application

Device technology BDB/S 1.1 Operating hours Way of counting adjustable Total runtime => starting from zero (count up) Remaining period => count down from an initial value (adjustable) Threshold adjustable Total runtime => Message if limit has been reached Remaining period => Message if zero has been reached Product overview / Device technology / Application

Device technology BDB/S 1.1 Total runtime Max. 100.000 h Transmission of a telegram Threshold - adjustable - changeable via bus Product overview / Device technology / Application

Device technology BDB/S 1.1 Remaining time Max. 100.000 h Initial value - adjustable - changeable via bus Transmission of a telegram Product overview / Device technology / Application

Device technology BDB/S 1.1 Switching operations Detection per channel Each action increases the counter Flank detection OFF -> ON ON -> OFF Counted and initial values, thresholds can be changed via bus Stored values, remaining- and initial values can be overwritten by download Product overview / Device technology / Application

Device technology BDB/S 1.1 Switching operations Way of counting adjustable Total value => starting from zero (count up) Remaining value => count down from an initial value (adjustable) Threshold adjustable Total value => Message if limit has been reached Remaining value => Message if zero has been reached Product overview / Device technology / Application

Device technology BDB/S 1.1 Total value Max. 4.294.967.295 Transmission of a telegram Threshold - adjustable - changeable via Bus Product overview / Device technology / Application

Device technology BDB/S 1.1 Remaining value Max. 4.294.967.295 Initial value - adjustable - changeable via bus Transmission of a telegram Product overview / Device technology / Application

Device technology BDB/S 1.1 Operating hours and switching operations 35 channels can be detected Receives all telegrams from the bus Starts cyclical polling (Read-Flag!) Thresholds adjustable Message on exceeding of a limit Counted- and initial values, thresholds can changed via bus Values will be stored steady Product overview / Device technology / Application

Application BDB/S 1.1 Illumination e.g. replacement of lamps after a defined operating time Ventilation e.g. filter Pumps e.g. under water pumps with strong wear Transportation systems e.g. elevators, escalators and conveyors Detection of operating hours and switching operations to coordinate maintenance and to recognize the life span of components Product overview / Device technology / Application