M.S.Sangeetha, C.V.Revanth

Slides:



Advertisements
Similar presentations
Pediatric CRRT: Terminology and Physiology
Advertisements

Hongjie Zhang Purge gas flow impact on tritium permeation Integrated simulation on tritium permeation in the solid breeder unit FNST, August 18-20, 2009.
Example: Electrokinetic valve
Sodium flux during dialysis
Louisiana Tech University Ruston, LA Slide 1 Co-Current and Counter-Current Exchange in Dialysis Steven A. Jones BIEN 501 Monday, May 5, 2008.
Elimination of Phosphate in HD and PD Reference: Kuhlmann MK. Phosphate elimination in modalities of hemodialysis and peritoneal dialysis. Blood Purif.
Types of Dialysis  1. Hemodialysis  2. Peritoneal dialysis – just be aware of it’s existence.
HEMODIALYSIS DIALYZER
Md.Kausher ahmed Electrical department. Biomedical engineering Code:6875.
Urinary System. Secreted Substances Secreted Substances Hydroxybenzoates Hydroxybenzoates Hippurates Hippurates Neurotransmitters (dopamine) Neurotransmitters.
Bioseparation Dr. Kamal E. M. Elkahlout Chapter 3 Mass transfer.
Introduction to COMSOL Travis Campbell Developed for CHE 331 – Fall 2012 Oregon State University School of Chemical, Biological and Environmental Engineering.
Mass Transfer Coefficient
By: Raphael Chang (3) Yeo Kee Xuan (25) Yap Jian Shern.
INTRODUCTION Many heat and mass transfer processes in column apparatuses may be described by the convection – diffusion equation with a volume reaction.
Principles of dialysis
PCRRT Tûr'mə-nŏl'ə-jē Helen Currier BSN, RN, CNN Assistant Director, Renal/Pheresis Texas Children’s Hospital Houston, Texas.
Nelson Research, Inc – N. 88 th St. Seattle, WA USA aol.com 2D Convective and Diffusive Fluid Flow in Porous Reaction.
Counter-current flows in liquid-liquid boundary layers II. Mass transfer kinetics E. Horvath 1, E. Nagy 1, Chr. Boyadjiev 2, J. Gyenis 1 1 University.
This study processes the optimization of heat extraction under the varied pressure and flow rate. Based on the validated model, two kinds of test tube.
BASIC PRINCIPLES OF DIALYSIS
Date of download: 9/26/2017 Copyright © ASME. All rights reserved.

Hamdache Abderrazaq 1*, Belkacem Mohamed 1, Hannoun Nourredine 2
RENAL REPLACEMENT THERAPIES
HAEMODIALYSIS Shofa chasani.
Prepared BY: Helwan University Faculty Of Engineering
The optimal parameters of geothermal energy based on supercritical CO2
Spotlight on general principles of hemodialysis
Hemodialysis I Lecture (1).
Transport phenomena in biological systems
11th International Conference on Mechanical Engineering (ICME2015)
Modeling and experimental study of coupled porous/channel flow
Hemodialyzer: From macro-design to membrane nanostructure; the case of the FX- class of hemodialyzers  Claudio Ronco, Sudhir Kumar Bowry, Alessandra Brendolan,
Title J. A. Smith1, M. B. Fields2
Title J. A. Smith1, M. B. Fields2
Title J. A. Smith, M. B. Fields2
Downloadable computer models for renal replacement therapy
COMSOL Simulation of Air Pollutant Particle Transmission in a Building
Elaine M. Spalding, Paul W. Chamney, Ken Farrington 
Hemodialysis: Core Curriculum 2014
Title J. A. Smith1, M. B. Fields2
Volume 54, Issue 3, Pages (September 1998)
Pediatric CRRT Terminology
Volume 55, Issue 2, Pages (February 1999)
Volume 67, Issue 2, Pages (February 2005)
Title that Underlines the Scope of Your Work
Diffusion Across Channels and Along Pores
Title that Underlines the Scope of Your Work
Basics of CRRT: Terminology
Volume 66, Pages S3-S24 (July 2004)
Erratum Regarding “Phosphate Removal With Several Thrice-Weekly Dialysis Methods in Overweight Hemodialysis Patients” [Am J Kidney Dis 2009; 54: ] 
Effects of a reduced inner diameter of hollow fibers in hemodialyzers
Continuous Renal Replacement Therapy
Rajdeep Ojha1, Vimal Chander1, Devakumar2
Product design from PRS to Prototype using Comsol Multiphysics
Volume 67, Issue 4, Pages (April 2005)
Please leave at least a 1” margin on all sides to avoid cropping during printing. Remove this text box before submitting. Title of Poster J. A. Smith1,
Shashank Bharadhwaj1, Mohd
Title J. A. Smith1, M. B. Fields2
Please leave at least a 25mm margin on all sides to avoid cropping during printing. Remove this text box before submitting. Title J. A. Smith1, M. B. Fields2.
Effects of a reduced inner diameter of hollow fibers in hemodialyzers
On-line mixed hemodiafiltration with a feedback for ultrafiltration control: Effect on middle-molecule removal  Luciano A. Pedrini, Vincenzo De Cristofaro 
Please leave at least a 1” margin on all sides to avoid cropping during printing. Remove this text box before submitting. Title of Poster J. A. Smith1,
Joachim Böhler, M.D., Johannes Donauer, Frieder Keller 
Volume 58, Issue 2, Pages (August 2000)
Volume 58, Issue 2, Pages (August 2000)
Confounding factors in the assessment of delivered hemodialysis dose
Group B Presenters: Erinne Munie, Tyler Roneker, Peter Marcote, Erik Freedmen Supported by our lovely researchers and assistants.
Quantitative Modeling and Optimization of Magnetic Tweezers
Presentation transcript:

Influence of fiber geometry on the performance of Hemodialyser membrane M.S.Sangeetha, C.V.Revanth Department of Biomedical Engineering, PSG College of Technology, Coimbatore, TN, India Introduction: Hemodialysis is the most widely used Renal Replacement Therapy for the treatment of failed kidneys. The hemodialyser known as the “Artificial kidney” is the replacement of the natural kidney and is the heart of the hemodialyser machine. The dialyser module comprises of thousands of hollow fibers which act as the semipermeable membrane to filter the impurities from the blood. One of the main challenges in hemodialyser membrane design is to enhance the clearance rate of solutes. Three dimensional models of the hemodialyser membrane were developed using COMSOL to study the impact of varying the fiber’s orientation (geometry). In the existing dialysers, the fibers are oriented in either straight or crimped configurations. The objective of the research work is to vary the fiber geometry and study the clearance rate of the solutes, hence comparative studies were performed on the transport characteristics of urea in straight and crimped models. This kind of analysis helps to design efficient hemodialyser membranes. Results:The initial concentration of urea assigned to the model is Cin=1000mol/m3. Using the Equation (3), the clearance rate K was calculated, where Qb is 200ml/min and Qd as 500ml/min. The simulations were carried out for straight fibers of length 56mm and 210 mm and crimped fibers having crimp frequency of 1, 2, 4 and 8 for the length of 56mm.The clearance rate of urea obtained for straight and crimped fibers are plotted in the graph.. (b) (a) (a) (b) (c) (d) Figure 1. (a) F6 HPS dialyser module (b) Schematic for 3D model Figure 2. Concentration profile of urea in crimped fiber with length 56mm (a) Cn=1 (b) Cn=2 (c) Cn=4 (d) Straight fiber of length 210 mm and Cn= 8 Computational Methods : The process of dialysis was simulated using the finite element solver and simulation software COMSOL Multiphysics 5.2 a. The models of the straight and crimped fibers were imported to the COMSOL environment through CAD import module. The geometry of the models were imported and the necessary parameters for computing the clearance i.e. blood flow rate, dialysate flow rate, membrane porosity, velocity for blood flow and dialysate flow, the number of fibers were fed as input parameters. Governing Equations The partial differential Equations are used in modeling the process of diffusion which is governed by Fick’s law. The chemical species transport module is used, which has two interfaces (i) Transport of diluted species and (ii) Species transport through porous media. The partial differential Equation (1) describes the diffusion and convection process which governs the dialysis process and aids the transport of solutes from the blood side to the dialysate side across the membrane. Both blood and dialysate were considered to have laminar flow. where, Di denotes the diffusion coefficient (m2/s), ci represents the concentration of the solute (mol/m3) in the liquid phase and u denotes the velocity (m/s) in the liquid phase. The diffusion coefficient was calculated from Equation where, MW is the molecular weight of the respective solute. The clearance rate is calculated using Equation where, K is the Clearance rate (ml/min), Qb is the Blood flow rate (ml/min), Cinis Inlet concentration of blood (mol/m3) and Cout is Outlet concentration of blood (mol/m3). Figure 3.For Qb= 200 ml/min and Qd= 500ml/min (a) Comparison of clearance rate of urea for straight and undulated fibers with varying crimp count (Cn) (b) Clearance profile of F6HPS Hemodialyser membrane Conclusions: The inference from the study is, the crimped fibers show good clearance rate of urea, when the order of crimping is increased for the same length of fiber. Hence the effect of crimping (altering the fiber geometry) enhances the filtration performance of the hemodialyser membrane. The results were validated with the experimental results obtained from the manufacturer’s data sheet, which is shown in Figure. References:   Triplitt, Curtis L, "Understanding the kidneys' role in blood glucose regulation" The American journal of managed care 18, no. 1 Suppl (2012): S11-6.16, 2012.  2. Davenport, Andrew, "How can dialyzer designs improve solute clearances for hemodialysis patients?" Hemodialysis International 18, no. S1 (2014): S43-S47. Islam, Md Shihamul, and Jerzy Szpunar. "Study of Dialyzer Membrane (Polyflux 210H) and Effects of Different Parameters on Dialysis Performance"Open Journal of Nephrology 3, no. 03 (2013): 161.  4. COMSOL help file – Separation through dialysis Keep this space clear for COMSOL use. Remove this text box before submitting.