remove 167 mL aliquot for Sr-90 spike with 1 mg stable Sr carrier

Slides:



Advertisements
Similar presentations
Ra in Water using MnO2 Resin: New Developments
Advertisements

Analysis of Actinide Elements from Large Environmental Samples
Anomalous Behavior of TEVA Resin Prepacked Columns: A Technical Update Anil Thakkar November 1st 2004 Cincinnati, OH.
The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
Copper Test. 1. Label the five beakers with their appropriate water sample names. 2. Put 10 mL of sample in their respective beakers.
Sample clean-up (MALDI)
Rapid Actinide Analysis for Large Soil Samples
New Applications of Rapid Column Extraction for Methods at SRS Sherrod L. Maxwell III Savannah River Site.
New Extraction Methods for Urine and Fecal Samples
D. P. DiPrete, C. C. DiPrete, and R. A. Sigg
Technical Updates on UTEVA, TEVA and TRU Resins
Optimizing Radiochemical Methods at SRS
% Calcium in Egg Shells By EDTA Complexometric Titration
Lecture 29 11/11/05.
Rapid Separation Methods for Bioassay Samples S. L. Maxwell, III and D. J. Fauth Westinghouse Savannah River Site.
BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS.
GROSS ALPHA DETERMINATION IN DRINKING WATER USING A HIGHLY SPECIFIC RESIN AND LSC
The Determination of 226 Ra in Water Samples Anil H. Thakkar Eichrom Technologies, Inc. eichrom TECHNOLOGIES INC.
The Determination Of 226 Ra In Soil Samples Lawrence D. Morris General Engineering Laboratories, Inc. Anil H. Thakkar Eichrom Technologies, Inc.
Determination of Sr-89/Sr-90 in primary cooling water
Radioactive Materials Analytical Laboratory Eichrom Technologies Inc. User Group Meeting May 2001 J.M. Giaquinto, L.D. Bible, D.C. Glasgow, J.M. Keller.
Concentration.
Rapid Actinide Analysis for Large Soil Samples-Update Sherrod L. Maxwell, III Westinghouse Savannah River Company.
00J ppt Rapid Extraction Methods for the Process Laboratory S. L. Maxwell, III V. D. Jones S. T. Nichols J. Satkowski M. A. Bernard Westinghouse.
Molarity By: Gurpreet Dulay & Kiranjit Kandola Some definitions The CONCENTRATION of a substance in solution is the amount of the substance which exists.
Developments in Environmental Radiochemistry* Environmental Radioactivity Measurement Facility Department of Oceanography Florida State University Tallahassee,
Distribution of radionuclides in soils in surroundings of Bratislava, capital of the Slovak Republic. II. Man-made radionuclides Mátel Ľ., Rosskopfová.
ICP MAKING STANDARDS. NUMBER OF STANDARDS Determine the number of standards necessary for your measurements (Blank, 100ppb, 500ppb, 1000ppb, etc)
The Determination of 226Ra in Water Samples
Updates from Eichrom’s Tech Support Lab Anil Thakkar May 4 th 2004 Charleston, SC.
New Extraction Methods for Actinides in Urine at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
Recent Improvements in Rapid Column Separation Methods at SRS S. L. Maxwell, III, D. J. Fauth, R. C. Henderson, J. J. Smiley, S. R. Johnson Westinghouse.
Th, Pu & U Separation Using TEVA and UTEVA Resin
Recent Improvements in Rapid Column Separation Methods at SRS
New Fecal Method for Plutonium and Americium at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
Determination of 210 Pb in mineral waters using Eichrom Resin Alžbeta Ďurecová, Dagmar Bursová, František Ďurec, Daniela Borošová State Institute of Public.
M M M M 5. Not Listed
New Fecal Method for Plutonium and Americium at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
Optimizing Radiochemical Methods at SRS (Ni-63, I-129, Actinides) Sherrod L. Maxwell, III Westinghouse Savannah River Company.
1 Learning Check If we dissolve 40.55g of FeCl 3 in enough water to make 500. mL of the solution, what is the molarity of the solution? Convert all unit:

Moles and Solutions - Concentrations
Yr 10 Chemistry Dilutions.
Anil H.Thakkar Eichrom Industries, Inc.. Darien, IL
Calcium Carbonate percent purity determination
The Determination of 226Ra in Water Samples
Strontium Extraction from Urine Samples
WATER QUALITY (Chapter 22)
Ra in Water using MnO2 Resin: Update
Determination of the Heat Solution
The Determination of 99Tc in waste by ICPMS A First Look D. K
Technical Updates on TRU and TEVA Resins
Determining Manganese in Steel
Determining Manganese in Steel
Rapid Emergency Methods for Actinides and Sr-89/90

Particulate and Dissolved 210Po and 210Pb in Water Columns from the
Diluting Solutions Lesson 6.
National Air and Radiation Environmental Lab
Times.
Balancing Redox Equations
Experiment No. 2 Preparation and standardization of approximately 0.1N sodium hydroxide (NaOH) by using standardized hydrochloric acid (HCl)
Aqueous Reactions and Solution Stoichiometry
Refining Sodium Chloride
C.2.10 Sample Questions.
C.2.8 Sample Questions.
Concentration = # of moles volume (L) V = 1000 mL V = 1000 mL
Molarity Calculate the concentration of a solute in terms of grams per liter, molarity, and percent composition.
C.2.8 Sample Questions.
Presentation transcript:

remove 167 mL aliquot for Sr-90 spike with 1 mg stable Sr carrier weigh 15 g aliquot ash digest in HNO3 / HCl / H2O2 dilute to 1000 mL remove 167 mL aliquot for Sr-90 spike with 1 mg stable Sr carrier dilute 167 mL aliquot to 1000 mL Remove 10 mL aliquot for ICP analysis pass thru cation exchange resin strip cations with HNO3, evaporate re-dissolve in 5 mL 8N HNO3 isolate Sr with Sr resin Remove 0.10 mL aliquot for ICP analysis evaporate onto planchet, count

About 25% of sample spilled in transfer step