Reheater Protection Logic

Slides:



Advertisements
Similar presentations
CONTROLS OF SUPER CRITICAL BOILERS
Advertisements

OFF DESIGN PERFORMANCE PREDICTION OF STEAM TURBINES
ACADs (08-006) Covered Keywords Defense-in-depth, reactor protection system, solid state protection system, reactor trips, Engineered Safety Feature System.
Adam Adgar School of Computing and Technology
Circulating Water System
Inner diameter or nominal size Schedule (wall thickness) Basic design criteria –Phase –Flow Pressure –Temperature Example: 2” Schedule 80.
CHEMICAL CLEANING OF PRE-BOILER SYSTEM
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
INDUSTRIAL TRAINING BHEL –EDN BANGLORE SARATH T.S M110278EE.
NERC Lessons Learned Summary December NERC lessons learned published in December 2014 Three NERC lessons learned (LL) were published in December.
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
HYDROPROCESSING PROJECT ARU / SWS – CONTROL SYSTEM and ESD
Example The following figure shows a reaction system in which the temperature increases with the feed rate of flow-controlled stream D. Heat is removed.
BUrners TRAining CEntre GULLIVER BLU HYDRAULIC SCHEME.
Summer Co-op Experience: OPG Aditi Garg. Darlington Nuclear G.S Located in Bowmanville, ON.
Example 1 - Superheat Rankine Cycle
Reheat cycle.
Turbine Protection and Control System
FUNCTIONS OF THE GOVERNING SYSTEM
1. Cooling tower. 2. Cooling water pump. 3. Transmission line (3-phase). 4. Unit transformer (3-phase). 5. Electric generator (3-phase). 6. Low pressure.
2 July Turbine Condensate System
ANY PIPE CONNECTION TO THE TURBINE IS A POTENTIAL SOURCE OF WATER EITHER BY INDUCTION FROM EXTERNAL EQUIPMENT OR BY ACCUMULATION OF CONDENSED STEAM.
UNICOS Objects (CPC) 11/02/14 UNICOS, CERN1 CERN, EN/ICE, UNICOS Team.
CHE 185 – PROCESS CONTROL AND DYNAMICS OPTIMIZATION AND PRIMARY LOOP ELEMENTS.
STEAM BOWING PROCEDURE OF STAGE # 1
Design Criteria for LP BYPASS SYSTEM
TURBINE & COOLING SYSTEM Presented By – AVIJEET PRATAP 07ME12 IET AGRA
Adani Power Limited Power Business Goal - 20,000 MW
STEAM TURBINE PROTECTIONS AND GOVERNING SYSTEMS
HP/LP BYPASS SYSTEM FUNCTION:
1 JSW Energy Limited of 149 RWPL MOPR – JULY - 14.
1 GENERATION TECHNOLOGIES -- Bhanu Bhushan -- (April, 2011)
Oven controller design documents Martijn Jasperse February 2011.
1 APP 4 th Peer Review in Australia “Brown Coal Best Practice Workshop” Summary of the Activities 27 June, 2008 The Federation of Electric Power Companies.
Eric Backus FW System Engineer Exelon - LaSalle Station FSRUG Executive Board Member.
BOILER PLANT OPERATION Presented By Mr. Sivanand Ray
Pipelines DYSTIFF s.r.o., Olomouc. Revamping of the Vacuum Distillation Unit Piping stress and strength calculation of 30 pipelines according to B31.3.
1. - Condensate pump and feed pump trip! -Turbine trips! 2.
Pengantar Pengendalian Proses
" GOVERNING & PROTECTION SYSTEM"
1 GENERATION TECHNOLOGIES -- Bhanu Bhushan -- (April, 2011)
Chandrapur # 7 – 500 MW Problem: Boiler trips On “Boiler Load Index” protection On tripping of Turbine Back to Technical Services.
Page 1 Petten 27 – Feb ALFRED and ELFR Secondary System and Plant Layout.
Why HIPPS ?? We have 600# (high pressure bearing) pipeline from well pads till production header. After that, we have 150# (low pressure bearing) pipeline.
CUE – Make Any Pump an E-Pump
"... To design the control system that effectively matches the plant requires an understanding of the plant rivaling that of the plant's designers, operators,
HP BY PASS WARM UP METHODS: (A) Equalising line with orifice (B) Drain line at upstream side of valve connected to downstream side of Main Steam line strainers.
Chandrapur # 7 – 500 MW Problem: Boiler trips On “Boiler Load Index” protection On tripping of Turbine.
A Presentation on THERMAL POWER PLANT Sunil Kumar M.E. (5TH)
SEMINAR ON ISLANDING BY PAWAN. What is islanding? Normally all Power generators are interconnected to form a network called ‘GRID’. Some times it so happens.
18 MW TURBINE CONTROL PANEL
IN THE NAME OF ALLAH, THE BENEFICENT, THE MERCIFUL
DEAERATOR-STAGE-II/TPS-II /NLC INDIA LTD
- Condensate pump and feed pump trip!
Date of download: 10/13/2017 Copyright © ASME. All rights reserved.
PRESSURE CONTROL VALVES (PCVs)
PID Temperature Controller
UBOH PLTU JAWA BARAT 2 PALABUHANRATU 3 x 350MW
THERMAL POWER PLANT.
PID Temperature Controller
THERMAL POWER PLANT.
- Condensate pump and feed pump trip!
Charge 2. Equipment Protection 3. Definition and Documentation
THERMAL POWER PLANT.
THERMAL POWER PLANT.
HAZOP Guidewords Base Set
Process Operability Class Materials Copyright © Thomas Marlin 2013
WATER AND STEAM SYSTEM.
 PURPOSE OF LUB OIL SYSTEM In the 250 MW KWU turbines :  Single oil is used for  A] Lubrication Of All Bearings,  B] Control Oil For Governing System.
BOILER PROTECTION AND INTERLOCKS
Presentation transcript:

Reheater Protection Logic HP Bypass System and Reheater Protection Logic

Supervisory and Monitoring Instrumentation

INSTRUMENTATION PRESSURE MEASUREMENT: TWO Nos. PRESSURE TRANSMITTERS PROVIDED IN THE UPSTREAM OF HP BYPASS PRESSURE CONTROL VALVES, IN THE MAIN STEAM LINE. RANGE : 0 TO 200 kg/sq.cm TEMPERATURE MEASUREMENT: TWO Nos. K-TYPE DUPLEX THERMOCOUPLES ARE PROVIDED IN EACH LINE, LOCATED AT THE DOWNSTREAM OF EACH HP BYPASS PRESSURE CONTROL VALVES. RANGE : 100 TO 450°C.

PROCESS MONITORING PRESSURE / TEMPERATURE MEASUREMENT: The 4 to 20 mA analog signals received from the Pressure transmitters and the mV signals received from Thermocouples are digitally processed in the DCS. These signals are monitored to generate internal and external digital signals for interlocks and alarm generation.

ALARMS, INTERLOCKS and PROTECTION The following are the main Alarms generated in the system: Pressure/Temperature transmitters failure. Main steam pressure too high. Downstream temperature high/very high. Tracking Pressure set point failure. Pressure control valves opened more than 2%. Pressure control valves closed less than 2%. Hydraulic Oil pressure too low. Any fast opening criteria operated. Any closing criteria operated.

ALARMS, INTERLOCKS and PROTECTION The following are the important interlocks provided in the system: When the Pressure control valves are closed less than 2% and in Manual mode, a forced close signal is provided to prevent the valve from drift open. When the Main steam pressure is too high, then the Fast opening device is activated. Whenever the pressure control valve is opened more than 2%, then the associated Spray control valve will switchover to Auto mode, if it was in Manual mode before. When the system is in auto mode and if the process signal is failed, then the associated control loop will be switched to manual mode.

ALARMS, INTERLOCKS and PROTECTION The following are the important interlocks provided in the system: When the down stream temperature of Pressure control valves is too high or when the condenser vacuum is low, then the Pressure control valves are closed on priority. When the Turbine trips or when the Generator CB is open, the opening device is activated to prevent Boiler trip.

LEGEND HP / LP BYPASS SYSTEM HRH MSL BP BOILER HPT MPT LPT CRH NRV CRH LPC CON BPE LBPE BD BFP LEGEND BP : HP BYPASS VALVE BD : HP SPRAY ISOLATION VALVE CON : CONDENSOR LBP: LP BYPASS VALVE BPE : HP SPRAY VALVE LBPE : LP SPRAY VALVE BFP: BOILER FEED PUMP CRH : COLD REHEAT LINE LPC : LP COOLER HPT: HIGH PRESSURE TURBINE HRH : HOT REHEAT LINE LPT : LOW PR. TURBINE MSL: MAIN STEAM LINE MPT : MEDIUM PR. TURBINE

HP BYPASS CONTROL SCHEME MAIN STEAM LINE To TURBINE P = BD TEMPERATURE SET POINT STATION MASTER PRESSURE CONTROLLER BPE PRESSURE SET POINT STATION TEMPERATURE CONTROLLER = T To CRH

Reheater Protection Logic