EGR 334 Thermodynamics Chapter 8: Sections 3-4

Slides:



Advertisements
Similar presentations
Use of Regeneration in Vapor Power Cycles
Advertisements

Chapter 11 Refrigeration Cycles Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 5th edition by Yunus A. Çengel.
Refrigeration Cycles د/ محمود عبدالوهاب.
Refrigeration Cycles CHAPTER 11: PTT 201/4 THERMODYNAMICS
EGR 334 Thermodynamics Chapter 12:
Lecture 02: Work and Energy
EGR 334 Thermodynamics Chapter 12: Sections 5-7
Chapter 10 VAPOR AND COMBINED POWER CYCLES
Rankine Cycle Figures from Cengel and Boles, Thermodynamics, An Engineering Approach, 6th ed., McGraw Hill, 2008.
EGR 334 Thermodynamics Chapter 3: Section 9-10
EGR 334 Thermodynamics Chapter 4: Section 4-5
10 CHAPTER Refrigeration Cycles.
Chapter 10 Vapor and Combined Power Cycles Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 6th edition by Yunus.
EGR 334 Thermodynamics Chapter 6: Sections 9-10
EGR 334 Thermodynamics Chapter 4: Section 10-12
EGR 334 Thermodynamics Chapter 4: Section 6-8
Reading: Cengel & Boles, Chapter 9
ENERGY CONVERSION ES 832a Eric Savory Lecture 12 – Large-scale plants Department of Mechanical and Material Engineering.
Example 1 - Superheat Rankine Cycle
Vapor and Combined Power Cycles
9 CHAPTER Vapor and Combined Power Cycles.
Chapter 1 VAPOR AND COMBINED POWER CYCLES
ES 202 Fluid and Thermal Systems Lecture 23: Power Cycles (2/4/2003)
Vapor Power Cycles Thermodynamics Professor Lee Carkner Lecture 19.
Vapor and Combined Power Cycles
Lec 23: Brayton cycle regeneration, Rankine cycle
EGR 334 Thermodynamics Chapter 6: Sections 11-13
EGR 334 Thermodynamics Chapter 4: Section 9-10
EGR 334 Thermodynamics Chapter 9: Sections 7-8
A Vapor Power Cycle Boiler T Turbine Compressor (pump) Heat exchanger
Thermal_Power_Plant_2 Prepared by: NMG
Cogeneration.
Power Generation Cycles Vapor Power Generation The Rankine Cycle
EGR 334 Thermodynamics Chapter 9: Sections 5-6
EGR 334 Thermodynamics Chapter 8: Sections 1-2
Chem. Eng. Thermodynamics (TKK-2137) 14/15 Semester 3 Instructor: Rama Oktavian Office Hr.: M.13-15, Tu , W ,
Thermodynamics II Chapter 1 VAPOR POWER CYCLES
Lesson 7 FIRST LAW OF THERMODYNAMICS STATE the First Law of Thermodynamics. Using the First Law of Thermodynamics, ANALYZE an open system including all.
Vapor and Combined Power Cycles (2)
Unit 4 Exercise – Gas Vapour and Combined Power Cycle
\ ME 200 L32 Today’s Class 8.3 Exams not picked up this week may be recycled! \ ME 200 L32 Utility Power Generation Self Study Assignment 8.2 Today’s Class.
Energy and the Environment Spring 2014 Instructor: Xiaodong Chu : Office Tel.: Mobile:
Lesson 8 SECOND LAW OF THERMODYNAMICS
Vapour Compression Refrigeration Systems
A Vapor Power Cycle Boiler T Turbine Compressor (pump) Heat exchanger
STEAM TURBINE POWER CYCLES. The vast majority of electrical generating plants are variations of vapour power plants in which water is the working fluid.
Chapter 10 VAPOR AND COMBINED POWER CYCLES
1 ChemE 260 Improvements and Non-Ideal Behavior in the Rankine Cycle May 20, 2005 Dr. William Baratuci Senior Lecturer Chemical Engineering Department.
Lecture Objectives: Finish with absorption cooling Power generation Rankine cycles Connect power generation with heating and cooling –CHP –CCHP.
Chapter 10 Vapor and Combined Power Cycles Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 7th edition by Yunus.
The Rankine Cycle: An Alternate Ideal Thermodynamic Model P M V Subbarao Professor Mechanical Engineering Department IIT Delhi A Feasible Mathematical.
ENGR 2213 Thermodynamics F. C. Lai School of Aerospace and Mechanical Engineering University of Oklahoma.
T s boiler turbine pump work in work out heat out heat in condenser superheated vapor saturated liquid & vapor compressed liquid critical point.
Superheat Rankine Cycle Example Turbine pump condenser Q out Q in W out W in boiler Consider the superheat Rankine power cycle as we analyzed before.
Chapter 10 VAPOR AND COMBINED POWER CYCLES
Chapter 10 VAPOR AND COMBINED POWER CYCLES
Vapor ,Gas and Combined Power Cycles
Objectives Evaluate the performance of gas power cycles for which the working fluid remains a gas throughout the entire cycle. Analyze vapor power.
Thermodynamics Cycles.
Lecture Objectives: Answer question related to Project 1 assignment
prepared by Laxmi institute tech. Mechanical eng. Department.
Simple Thermal Power Plant
TOPIC:- VAPOUR CYCLES CREATED BY:
RANKINE CYCLE IMPROVISATIONS BY PRABHAKARAN.T AP/MECH
Power and Refrigeration Systems
VAPOR & COMBINED POWER CYCLES
Power Plant Technology Steam and Gas Cycle Power Plant (Assignment 1)
9 CHAPTER Vapor and Combined Power Cycles.
Cogen, Regen Combined Cycle
Presentation transcript:

EGR 334 Thermodynamics Chapter 8: Sections 3-4 Lecture 32: Superheat, Reheat, and Cogeneration Quiz Today?

Today’s main concepts: Explain how a superheater changes the Rankine cycle model Explain how a reheat line changes the Rankine cycle model. Explain how regenerative heating changes the Rankine cycle model. Explain how cogeneration and process steam lines change the Rankine cycle model. Be able to use mass balance, energy balance, and entropy balance to solve systems with modified Rankine cycle models. Reading Assignment: Read Chapter 9, Sections 1-2 Homework Assignment: Problems from Chap 8: 21,29, 49, 60

Vapor Power System Model Sec 8.1 : Modeling Vapor Power Systems Vapor Power System Model

Conservation of energy (First Law) Entropy balance (Second Law) Sec 8.2 : Rankine Cycle Tools: Conservation of mass Conservation of energy (First Law) Entropy balance (Second Law) Thermodynamic properties Energy balances: For the turbine: For the condenser: For the pump: For the boiler:

Process 3-4: Isentropic compression of fluid to compressed liquid. Sec 8.2 : Rankine Cycle Process 1-2: Isentropic expansion of the fluid through the turbine from saturated vapor to the condenser pressure. Process 3-4: Isentropic compression of fluid to compressed liquid. Process 4-1: Heat transfer at constant pressure through the boiler to saturated vapor Process 2-3: Heat transfer at constant pressure through the condenser to saturated liquid.

Sec 8.2.2 : Modified Rankine Cycle In addition to being able to work with the Ideal Rankine Cycle, you should also be prepared to evaluate performance that includes the following modifications -- Superheating: Heating of the fluid past a saturated vapor and well into the superheated region by the steam generator. -- Reheating: Reheating fluid after it has passed through one turbine and then passing through a second turbine at lower pressure. -- Regenerative Feedwater Heating: A process where some of the steam is bled off and used to partially reheat the condensate from the condenser.

Sec 8.2.2 : Modified Rankine Cycle In addition to being able to work with the Ideal Rankine Cycle, you should also be prepared to evaluate performance that includes the following modifications -- Non-Ideal Rankine (with irreversibilities): Similar to the Ideal Rankine cycle except the processes through the turbine and pump are not isentropic. Turbine and pump efficiencies need to be used to determine work in each of the components. -- Cogeneration: A process where some of the steam is bled off for use by other parts of the plant, such as for heating, cleaning, etc.

How can the efficiency of the Rankine cycle be increased? Sec 8.3 : Superheat and Reheat How can the efficiency of the Rankine cycle be increased? Raise the Average High Temperature. As the temperature is raised, note that the sat. vapor location also shifts to the left, so that when the fluid expands through the turbine, a lower quality of the fluid is obtained. Why is this bad? Net work is decreased as area under the curve get narrower and there are physical effects on the turbine that involve more blade wear. It is more desirable to have the exit quality of the steam, x2, be above 90% How can the cycle maintain high boiler Pressure and Temperature and still maintain a higher exit quality? Superheat the steam.

How is steam superheated?

Sec 8.3 : Superheat and Reheat Superheating: It is not necessary to have the exit from the boiler be a saturated vapor (xboiler exit = 1). Operate the boiler, such that the exit of the boiler is a superheated vapor. http://www.powerfromthesun.net/chapter12/Chapter12new.htm The only difference in calculating cycle performance from the Ideal Rankine Cycle, is that state 3 is no longer expected to fall along the saturated vapor curve, but will be found on the superheated steam table.

Sec 8.3 : Superheat and Reheat When Reheating is implemented, there is a multistage stage turbine (often identified as a High Pressure and Low Pressure turbine.) Before vapor starts to condense (reaches saturation), the vapor is sent back to the boiler and reheated.

Sec 8.3 : Superheat and Reheat This affects the Ideal Rankine Cycle model because there are additional states to determine properties for, a second pass through the turbine, and a second heat exchange with the boiler. Therefore, identify additional properties states (1, 2, 3, and 4) and then rework the 1st law equations as applied to the turbine and boiler. and Boiler Reheat Equation

Regenerative Feedwater Heating. (regeneration) Sec 8.4 : Regenerative Vapor Power Cycle Regenerative Feedwater Heating. (regeneration) Steam is diverted to use in a mixing chamber to preheat the condensate prior to entering boiler. This is useful since water is typically cooled below saturated level out of the condensor. Note: This rerouting will diminish the net work output. The reduction in Qboiler should be less than the reduction of Wcycle.

Open feedwater analysis: #2 Sec 8.4 : Regenerative Vapor Power Cycle Open feedwater analysis: #2 Mass Balance: #1 #3 Often will use the term “blend fraction” consequently, Energy Balance: Thus:

Energy balances: For the turbines: and For the condenser: Sec 8.4 : Regenerative Vapor Power Cycle Energy balances: For the turbines: and For the condenser: For the pump: For the boiler:

The net power developed, in Btu/hr. The thermal efficiency. Example (8.44): An Ideal Rankine cycle with the state properties given below includes one open feedwater heater operating at 100 psi. Saturated liquid exits the open feedwater heater at 100 psi. The mass flow rate of steam into the first turbine state is 1.4 x 106 lbm/hr. Determine The net power developed, in Btu/hr. The thermal efficiency. The mass flow rate of cooling water, if T = 20°F. State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x h (Btu/lbm) s (Btu/lbm K)

Start by finding the state properties Example (8.44) continued: Start by finding the state properties State 1: Using Table A4E with T = 1100 F and p = 1600 psi, find h1 = 1547.7 and s1 = 1.6315 State 2: Using Table A4E with s2=s1 and p = 100 psi, find h2 = 1210.7 State 3: Using Table A3E with s3=s1, and p = 1 psi, find x3 = 81.2% and then, find h3 = 911.2 State 4: Using Table A3E with sat. liquid and p = 1 psi, find v4 = vf = 0.01614, h4 = hf = 69.74, and s4 = sf = 0.1327 State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x h (Btu/lbm) s (Btu/lbm K)

Start by finding the state properties Example (8.44) continued: Start by finding the state properties State 5: Using h5 - h4 =v4 (p5 - p4) find h5 = 70.04 State 6: Using Table A4E with sat. liq. and p = 100 psi, find v6 = 0.01774 h6 = 298.6, and s6 = 0.4744 State 7: Using h7 - h6 =v6 (p7 - p6) find h7 = 303.5 State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x h (Btu/lbm) s (Btu/lbm K) State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x s.h. 0.812 0.00 liq. h (Btu/lbm) 1547.7 1210.7 911.2 69.74 70.04 298.6 303.5 s (Btu/lbm K) 1.6315 0.1327 0.4744

Find heat in provided in boiler: Example (8.44) continued: Find heat in provided in boiler: then State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x s.h. 0.812 0.00 liq. h (Btu/lbm) 1547.7 1210.7 911.2 69.74 70.04 298.6 303.5 s (Btu/lbm K) 1.6315 0.1327 0.4744

Now find how the mass flow splits from the turbine Example (8.44) continued: Now find how the mass flow splits from the turbine c therefore: State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x s.h. 0.812 0.00 liq. h (Btu/lbm) 1547.7 1210.7 911.2 69.74 70.04 298.6 303.5 s (Btu/lbm K) 1.6315 0.1327 0.4744

Example (8.44) continued: Find work from turbine State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x s.h. 0.812 0.00 liq. h (Btu/lbm) 1547.7 1210.7 911.2 69.74 70.04 298.6 303.5 s (Btu/lbm K) 1.6315 0.1327 0.4744

Find heat provided to pumps: Example (8.44) continued: Find heat provided to pumps: Pump 1: Pump 2: State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x s.h. 0.812 0.00 liq. h (Btu/lbm) 1547.7 1210.7 911.2 69.74 70.04 298.6 303.5 s (Btu/lbm K) 1.6315 0.1327 0.4744

Plant thermal efficiency: Example (8.44) continued: therefore the Net Work Plant thermal efficiency: State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x s.h. 0.812 0.00 liq. h (Btu/lbm) 1547.7 1210.7 911.2 69.74 70.04 298.6 303.5 s (Btu/lbm K) 1.6315 0.1327 0.4744

Example (8.44) continued: for the condenser: State 1 2 3 4 5 6 7 T (°F) 1100 p (psi) 1600 100 x s.h. 0.812 0.00 liq. h (Btu/lbm) 1547.7 1210.7 911.2 69.74 70.04 298.6 303.5 s (Btu/lbm K) 1.6315 0.1327 0.4744

NonIdeal Rankine Cycle. Sec 8.2.4 : Principal Irreversibilities and Losses NonIdeal Rankine Cycle. For real processes, there is some heat transfer with the surroundings, and thus an increase in entropy. In the turbine and pump, this can be quantified using the isentropic efficiencies. For Turbine: For Pump: But, for a real process, the inefficiencies associated with combustion are more significant. These, however, are external to the power cycle, so are not analyzed as part of the Rankine Cycle analysis.

Cogeneration Systems Cogeneration systems provide both electrical work out and process steam or hot water for use by an end user which is often a commerical, industrial, or governmental user. Steam exported to the community Electricity provided to the community

Cogeneration Systems --Exporting useful steam to the community limits the electricity that also can be provided from a given fuel input, however. --For instance, to produce saturated vapor at 100oC (1 atm) for export to the community water circulating through the power plant will condense at a higher temperature and thus at a higher pressure. --In such an operating mode thermal efficiency is less than when condensation occurs at a pressure below 1 atm, as in a plant fully dedicated to power production. T > 100oC p > 1 atm

Sec 8.4.3 : Multiple Feedwater Heaters As closing comment: You now have most of the tools you would need to analyze some relatively complicated vapor power generation units and be able to discuss their respective efficiencies or how to suggest improvements in their performance... (not that you would want to).

End of Lecture 32 slides So ends Chap 8!