Combustion Control for Boilers

Slides:



Advertisements
Similar presentations
Spring Process Control Spring Outline 1.Optimization 2.Statistical Process Control 3.In-Process Control.
Advertisements

CONTROLS OF SUPER CRITICAL BOILERS
ACTIVE LEARNING PROCESS
17 May Multiple Sites. 17 May Multiple Sites This presentation assumes you are already familiar with Doors and all its standard commands It.
* A chiller capable of producing water temperatures of low 40s on the evaporator side and above 135° on the condenser side.
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Industrial Boilers Steam generators Closed vessels made of steel and
ACTIVE LEARNING PROCESS
1 BOILERS AND EFFICIENCY Gary Archer Vice President of Sales JW Stevens Co.
Power Plant Engineering
Fired And Unfired Pressure Vessels
Lecture Notes - Energy Conservation Topic “Boiler”
HVAC523 Heat Sources.
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Triangle Tube Boiler Fuel Cost Savings Worksheet Prepared for: Customer Name: Street: City, State, Zip: Day Phone: Evening Phone: Cell Phone:
ENERGY SAVING IN STEAM GENERATION AND TRANSPORT IN FOOD INDUSTRY
Different methods of energy conservation
Energy Efficient Steam Systems
Factor of Evaporation: lbs/hr steam produced per BHp.
Energy Efficiencies Opportunities for SMEs … An effective tool to sustain bottom line Tuesday, April 2, 2013.
Boilers Dept. of Mech & Mfg. Engg..
ACTIVE LEARNING PROCESS Prepared By : BHATT HARSHIT 13BEECM026 SOLANKI KAUSHAL 13BEECM033 Guided By : Prof. J M Panchal Branch: Electronics & Communication.
INTRODUCTION. Seminar on IMPROVEMENT OF THERMAL EFFICIENCY BY RECOVERY OF HEAT FROM IC ENGINE EXHAUST.
Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan assisted NIKE Star 23 kW EOLO Star 23 kW.
8 April Doors TM Set System Options. 8 April Set System Options Allows you to set certain standard Doors operating parameters and enable certain.
Energy Service Productivity Management ©2007 ESPM Energy Consultants, L.L.C. All Rights Reserved.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Watertube Boiler.
Vapor and Combined Power Cycles
Pharos University جامعه فاروس Faculty of Engineering كلية الهندسة Petrochemical Department قسم البتروكيماويات PE 330 ENERGY CONSERVATION LECTURE (9) ENERGY.
Steam Power Plant.
Coal Burning System.
CASE STUDY ENERGY CONSERVATION OPPORTUNITIES at A Foundry at Bhiwadi (Rajasthan)
POWER PLANT.
POWER GENERATION TECHNOLOGIES
Lesson 7 Steam Power Plant.
B OILER Presented by: Muhammad Azffar Mohamad Hanif bin Yusof Nor Aminah bt. Mohd Khalil
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Theory of Steam Generation P M V Subbarao Professor Mechanical Engineering Department Progressive Development of Power Generation through Steam Generation……
Pharos University جامعه فاروس Faculty of Engineering كلية الهندسة Petrochemical Department قسم البتروكيماويات PE 330 ENERGY CONSERVATION LECTURE (5) Flue.
Steam Power Station Presented By Ashvin G. Patel Asst. Prof. (E.E.)
Nuclear Power Station Lecture No 5. A generating station in which nuclear energy is converted into electrical energy is known as a Nuclear power station.
Gas Turbine Power Plant
1 Combustion Oil Fired Equipment. 2 OIL Combustion of oil fired equipment has the same basics of gas. Remember, Oil is a liquid and this must be converted.
STUDY OF BOILER’S ACCESSORIES
Richard Kelly, D.I.T.1 Facilities Management and the Environment BSc in Electrical Services and Energy Management.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
AIM :- TO STUDY ABOUT STEAM POWER PLANT
Presentation Dungrani rakesh v. Div : a Branch : mechenical Sem : 1 st.
1 HVACR215 – Mechanical for Oil Oil Combustion. 2 Combustion The burning of a substance. Rapid Oxidation The burning of a substance. Rapid Oxidation.
Unit 2 -Gas And Diesel Power Plants
Generating Stations. Bulk electric power is produced by special plants known as generating stations or power plants. Depending upon the form of energy.
STEAM POWER PLANTS.
ENERGY EFFICIENCY IN THERMAL UTILITIES AND SYSTEM
A Seminar On Suratgarh Super Thermal Power Station (Raj.)
THERMAL POWER PLANT. INTRODUCTION : THERMAL POWER PLANTS CONVERT THE HEAT ENERGY OF COAL INTO ELECTRICAL ENERGY. COAL IS BURNT IN A BOILER WHICH CONVERTS.
SURATGARH SUPER THARMAL POWER STATION
BOILER MOUNTINGS & ACCESSORIES
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
Prepared by : Nishant .A. Raval
Lancom 4 In Power and Boilers Derek Stuart. Lancom 4 In Power and Boilers Derek Stuart Combustion Theory In order to maximize the heat capture (efficiency)
Thermal power plant , panipat
Gas Turbine Power Plant
Lesson 7 Steam Power Plant.
Gas Power Plant - Layout and Operation
Fulfilled the student of group ФЭ14-01B Zhuk Aleksey
Desuperheater Best Heat Transfer Device Used In Various Industries
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
Presentation transcript:

Combustion Control for Boilers September 23, 2004

Contents Introduction Basic type of boilers. Why need boiler controls? Combustion control for boilers. Fuji’s oxygen gas analyzer. September 23, 2004

1. Introduction How does a boiler works? A boiler is a water containing vessel which transfers heat from a fuel source (oil, gas or coal) into steam which is piped to a point where it can be used to run production equipment, to sterilize, to provide heat, to steam-clean, etc. The energy given up by the steam is sufficient to convert it back into the form of water. When 100% of the steam produced is returned to be reused, the system is called a closed system. Since some processes can contaminate the steam, so it is not always desirable to feed the condensate back into the boiler. A system that does not return the condensate is called an open system. September 23, 2004

1. Introduction Closed system September 23, 2004

1. Introduction Open system September 23, 2004

2. Basic type of boilers. The two main types of boilers are: Firetube Watertube September 23, 2004

2. Basic type of boilers. Firetube Fire or hot gases are directed through the inside of tubes within the boiler shell which are surrounded by water. The tubes are arranged in banks so that the gases can be passed through the boiler up to 4 times before passing out the stack. This system exposes the maximum heat transfer surface to the water. Firetube boilers are also known as shell boilers and can produce up to approximately 750 hp or 25,000 lbs of steam per hour. 80% of boilers in use are of this configuration. September 23, 2004

2. Basic type of boilers. Firetube September 23, 2004

2. Basic type of boilers. Firetube September 23, 2004

2. Basic type of boilers. Watertube Fire or hot gases are directed to and around the outside of tubes containing water, arranged in a vertical position. Watertube boilers are usually rectangular in shape and have two or more drums. The separation of steam and water takes place in the top drum, while the bottom drum serves as a collection point for sludge. This system is usually used when more than 750 hp or several hundred thousand lbs of steam per hour, are needed. There are other designs with special configurations, adapting them to particular applications September 23, 2004

2. Basic type of boilers. Watertube September 23, 2004

2. Basic type of boilers. Watertube September 23, 2004

3. Why need boiler controls? Boiler efficiency relates the boilers energy output to the boilers energy input and can be expressed as:- Boiler efficiency (%) = Heat exported by fluid/Heat provided by fuel An accurate control of the amount of air is essential to the boiler efficiency.  Too much air will cool the furnace and carried away useful heat. And too little air and the combustion will be incomplete. Unburned fuel will be carried over and smoke may be produced. September 23, 2004

3. Why need boiler controls? Increase uptime and availability Reduce flue gas emissions Maintain boiler safety Control operating costs September 23, 2004

3. Why need boiler controls? Increase uptime and availability The primary objective of most boilers operation is maintaining the uptime and availability. It is essential to maintain and upgrade the boiler control systems to assure steam availability. Modern controls are more reliable and can be readily adjusts to load swings caused by varying plant operations. September 23, 2004

3. Why need boiler controls? Reduce flue gas emissions Failure to comply with the current emissions regulations can be as costly as loss of utilities. Government mandates are enforced by fines, threat of closure, or imprisonment will provide sufficient incentives for plants to comply with the regulations; thus, modernize controls are necessary. Improved in combustion efficiency means reduction in waste disposal problems. And by accurately controlling the oxygen, fuel flow and stack temperature, you will see reductions in plant emissions. September 23, 2004

3. Why need boiler controls? Maintain boiler safety Modernize control system will have tight integration with flame safety or burner management system to improve safety. Accessing field data, diagnostics functions and alarms can be achieved by coupling modern electronic controls. Password security of the configuration software also assures no unintended changes can be done which can endanger your personnel and equipment. September 23, 2004

3. Why need boiler controls? Control operating costs Reduction in fuel consumption Reduction in engineering, installation and startup costs Reduction maintenance costs associated with older equipment Reduction manpower with automatic responds Provide a flexible control strategy to reduce process upsets Readily data available for remote monitoring to determine process optimization, boiler efficiency and load allocations September 23, 2004

4. Combustion control for boilers. Burner combustion control generally includes one or a combination of the following methods:- Excess air regulation Oxygen trim Burner modulation Air/Fuel cross-limiting Total heat control September 23, 2004

4. Combustion control for boilers. Excess air regulation In actual practice, gas , oil, coal burning and other systems do not do a a perfect job of mixing the fuel and air even under the best achievable conditions. Additionally, complete mixing may be a lengthy process. To ensure complete combustion and reduce heat loss, excess air has to be kept within suitable range. The regulation of excess air provides:- A better boilers hear transfer rate An advance warming of flue gas problems Excess air coming out of the zone of maximum efficiently Substantial savings on fuel September 23, 2004

4. Combustion control for boilers. Excess air regulation September 23, 2004

4. Combustion control for boilers. Oxygen trim When a measurement of oxygen in the flue gas is available, the combustion control mechanism can be vastly improved (since the percentage of oxygen in flue is closely related to the amount of excess air) by adding an oxygen trim control module, allowing Tighter control of excess air to oxygen setpoint for better efficiency Faster return to setpoint following disturbances Tighter control over flue emissions Compliance with emission standards Easy incorporation of carbon monoxide or capacity override September 23, 2004

4. Combustion control for boilers. Oxygen trim September 23, 2004

4. Combustion control for boilers. Burner modulation Modulating control is a basic improvement in controlling combustion. A continuous control signal is generated by a controller monitoring the steam or hot water line. Reductions in steam pressure or hot water temperature lead to an increase in firing rate. The advantages of introducing burner modulation in combustion control include. Fuel and air requirements are continuously matched to the combustion demand Steam pressure or hot water temperature is maintained within closer tolerances Greater boiler efficiency Weighted average flue gas temperature is lower September 23, 2004

4. Combustion control for boilers. Air/Fuel cross-limiting A cross limiting combustion control strategy ensures that there can never be a dangerous ration of air and fuel within a combustion process. This is implemented by always raising the air flow before allowing the fuel flow to increase or by lowering the fuel flow before allowing the air flow to drop. Cross-limiting combustion control is highly effective and can easily provide the followings Optimization of fuel consumption Safer operating condition by reducing risk of explosion Fast adaptation to variation in fuel and air supplies Satisfaction of the plant demand fore steam September 23, 2004

4. Combustion control for boilers. Air/Fuel cross-limiting September 23, 2004

4. Combustion control for boilers. Total heat control A cross limiting combustion control strategy ensures that there can never be a dangerous ration of air and fuel within a combustion process. This is implemented by always raising the air flow before allowing the fuel flow to increase or by lowering the fuel flow before allowing the air flow to drop. September 23, 2004

4. Combustion control for boilers. Total heat control September 23, 2004

4. Fuji’s oxygen gas analyzer. Top class performance zirconia oxygen analyzer September 23, 2004

4. Fuji’s oxygen gas analyzer. Accurate O2 Measurement is Essential for Energy Saving!  The oxygen analyzer consists of a compact zirconia detector that can be inserted directly in wall of the flowing sample gas. The detector measures the oxygen content in the flowing sample gas and transmits the signal to the converter. The converter will then trigger the ON-OFF alarm based on the preset oxygen concentration and give control signal to other devices. Fuji Electric’s oxygen analyzer has a unique construction that eliminates the necessity of aspirating sampling gas or injecting air. And make it extremely suitable for monitoring and controlling combustion system like, heater boiler, kiln, melting furnace, low oxygen warehouse and food packing machine. September 23, 2004

4. Fuji’s oxygen gas analyzer. Excess air coefficient and energy loss ratio Excess Air Coefficient Exhaust Oxygen, O2 (%) Energy Loss Ratio, Exhaust Gas (%) 1.1 1.9 9.4 1.2 3.5 10.3 1.3 4.8 11.1 1.4 6.0 12.0 1.6 7.9 13.7 (In the case of heavy oil combustion at exhaust gas temperature of 250 °C and atmospheric temperature of 20 °C) September 23, 2004

4. Fuji’s oxygen gas analyzer. Calculation of cost saving with improved combustion efficiency (The data may varies based on the construction and performance of the boilers) Item Case 1 Case 2 Evaporation rate from boiler 5ton/hr 1ton/hr Annual operating hours 2,000hrs Evaporation multiplier factor for boiler 12 Improved value of excessive air coefficient 1.6 -> 1.2 (O2 gas from 7.9% -> 3.5%) Kerosene price USD 1.05/kg (USD 0.82/ℓ, SG 0.78) Kerosene consumption rate 5,000kg/hr ÷ 12 = 420kg/hr 2,000kg/hr ÷ 12 = 85kg/hr Annual saving through the improved combustion efficiency 420kg/hr x USD 1.05/kg x (13.7 – 10.3) % x 2,000hrs = USD 29,988.00 85kg/hr x USD 1.05/kg x (13.7 – 10.3) % x 2,000hrs = USD 6,069.00 Note: The data shown in the above table are calculated on an assumption of improvement of energy loss = full reduction ratio, therefore the combustion efficiency of the boiler must be taken into account for calculating fuel reduction rate accurately. Fuel reduction ratio will therefore be least several percent higher in actuality. September 23, 2004

4. Fuji’s oxygen gas analyzer. Advantages: No sampling device is required The instrument requires no gas aspirating pump or ejector for normal measurements; therefore it can be operated easily. It can be used very conveniently like traditional thermocouple. Compact and light weight design The detector and converter weigh about 1.6kg and 3.5kg respectively. Instrument equipped with indicator and transmitting function The converter is equipped with an indicator that permits direct readout of the oxygen concentration transmitting output function or RS485 communication. Alarm and control functions available Though compact it is compact and lightweight in design, the converter consists of an oxygen concentration setting mechanism as well as alarm setting and control circuits that can transmit control signals. Lost cost Comparing Zircomat-P with other conventional oxygen analyzers it is much more economical in cost. Easy maintenance Zircomat-P assures easier maintenance comparing to other conventional oxygen analyzers and can be used under severe site conditions for a long time. September 23, 2004

4. Fuji’s oxygen gas analyzer. System Outline September 23, 2004

4. Fuji’s oxygen gas analyzer. Technical Specifications Measuring range 0 to 2 ~ 50% Repeatability Within ± 0.5% maximum output signal Linearity ± 2% full scale Response time With 7 seconds Power Supply 100, 115, 220 or 230 Vac, 50/60Hz Power consumption 15 + 50VA Warm up time 15minutes   Detector Type Direct insertion type zirconia detector Applicable gas temperature -20~+600 °C or -20~+1,590 °C Sample gas pressure -3~+3kPa (-306~+306mmH2O) Ambient temperature -20~+60 °C or -5~100 °C Converter Output signal 4~20mA or 0~1Vdc Indication oxygen concentration 3-digits LED Indication operation/settings 16-digits LCD Mode display 03 x LED Mounting Panel or Pipe Mounting Optional function RS-485 September 23, 2004

4. Fuji’s oxygen gas analyzer. Standard air ratio by Energy Economy Law in Japan for conservation of energy   Based on Article 4, Clause 1 of the law regarding rational use of energy (Law No. 49 published in 1979), judging standard for enterprisers at factories (Notification No. 467 of the Ministry of Commerce and Industry, dated October 1979) has been amended on October 26, 1979 (Notification No. 559 of the Ministry of Commerce and Industry) to specify standard air ratio. 1. Boilers Classification Load Ratio (%) Standard air ratio Solid Fuel Liquid fuel Gaseous fuel Blast furnace gas For electrical enterprise 75~100 1.2~1.3 1.05~1.1 1.2 Others   Evaporation rate exceeding 30ton/hr 1.1~1.2 1.3 Evaporation rate from 10~30ton/hr - Evaporation rate not exceeding 10ton/hr September 23, 2004

4. Fuji’s oxygen gas analyzer. 2. Industrial Furnaces Classification Standard air Ratio Metal melting furnace 1.3 Continuous steel heating furnace 1.25 Metal heating furnace not continuous steel heating type Continuous thermal treatment furnace Gas producer and gas heating furnace 1.4 Oil heating furnace Pyrolytic furnace and modification furnace Cement kiln Alumina kiln and lime kiln Continuous glass melting kiln September 23, 2004

The End September 23, 2004