Tracer Applications.

Slides:



Advertisements
Similar presentations
Quiz – An organic liquid enters a in. ID horizontal steel tube, 3.5 ft long, at a rate of 5000 lb/hr. You are given that the specific.
Advertisements

Basic Refrigeration Cycle
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
Calculating Efficiency Opportunities in Insulation Workgroup Meeting May 2014 Charlie Schreier, PE Engineer.
STEAM TRAPS.
Ground Loop Design. Heat Sources Horizontal ground loops  Collector pipework laid horizontally  Requires large land area  Cost.
So Far: Conservation of Mass and Energy Pressure Drop in Pipes Flow Measurement Instruments Flow Control (Valves) Types of Pumps and Pump Sizing This Week:
Superheaters.
Driving Toward Energy Efficiency Emerson Process Management Novaspect. Inc. June 22 / 23, 2010 Steam.
Engineer Presentation
©2005 Armstrong International, Inc. Open and Closed Systems.
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
COMMERCIAL REFRIGERATION
EGR 334 Thermodynamics Chapter 4: Section 9-10
STEAM CONDENSERS.
COMMERCIAL REFRIGERATION
Oil Pressure Problems What to look for.
STEAM HEATING.
Mechanical for Oil Heat
©2005 Armstrong International, Inc. Proper Piping Practices (Pumps)
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
Heat Exchanger Stall.
Refrigerant Piping A Trane Air Conditioning Clinic Air Conditioning Clinic TRG-TRC006-EN © American Standard Inc
Pharos University. جامعه فاروس Faculty of Engineering
Mounting Direction Water Cooler Best solution OK Risk of air bubbles in the system Heatsink Water channels Inlet Outlet.
COOLING TOWER Prof. Osama El Masry.
FEASIBILITY OF COMPONENTS CLARA ECHAVARRIA & JONATHON LOCKE.
Plan 2 – Dead-end Seal Chamber Optional Jacket
Clean and Pure steam in the Biopharm industry
23 Jan 2007 LASA Cryogenics Global Group 1 ILC Cryomodule piping L. Tavian for the cryogenics global group.
NSTX TF Bundle & Center Stack Curing Oven Mike Viola Joe Rushinski Frank Jones April 14, 2003.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
SIZING PNEUMATIC SYSTEMS. Introduction Pneumatic systems are sized to meet output power requirements. The air distribution system is sized to carry the.
Senior Design Team #18 Lacey Ednoff Brianna Beconovich Jarimy Passmore Jesse Poorman.
The Importance of Distribution. Manifold Position And Vapor Trail.
So Far: Conservation of Mass and Energy Pressure Drop in Pipes Flow Measurement Instruments Flow Control (Valves) Types of Pumps and Pump Sizing This Week:
Master Brewer Program (6 Weeks) 1. Fluids fundamentals and equipment. 2. Fluids test. Heat transfer fundamentals and equipment. 3. Heat transfer test.
Section 3 Using Heat.
Heat Transfer Equations. Fouling Layers of dirt, particles, biological growth, etc. effect resistance to heat transfer We cannot predict fouling factors.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Friction Loss Tutorial Used in conjunction with the Friction Loss Check Sheet and any Irrigation Plan.
Exercises for Q1. Insulated copper tube A thin walled 10 mm copper tube is used to transport a low-temperature refrigerant with a temperature that is.
Tank Heating by Various Methods for Metal Finishing and Other Process Heating Applications OVERVIEW 1.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
ME444 ENGINEERING PIPING SYSTEM DESIGN
Energy In Buildings By Mina Greas  Lighting and Daylighting  Water Heating Systems.
Michael A. Green and Heng Pan
Greenhouse Management
ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES.
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
Chemical Engineering Drawing
Condensate Management
Evaporator Design for concentrating cane juice
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Conservation of Mass and Energy
Date of download: 3/4/2018 Copyright © ASME. All rights reserved.
COOLING TOWER.
Cisterns and Insulation
Corrosion & Associated Degradation
Heat Exchangers Heat Exchangers.
GENERALPIPINGREQUIREMENTS:. Designing and erecting an efficient piping system requires certain aspects/ requirements which could be found in our PME handbook…
FBE03: Building Construction & Science
Condensate Recovery Equipment
1 INTERNATIONAL MARITIME COLLEGE OMAN PROCESS TECHNOLOGY & SYSTEMS (TPTS & PT-TPTS) PE (TPTS & PT-TPTS) (Chapter-3) Chapter - 3 Distillation Systems Textbook.
Steam traps Applications and Recommendations
Chapter 6 Cyclones.
Cooling System In I.C.E.
Presentation transcript:

Tracer Applications

Typical Steam Tracing Piping distribution Spares manifold Steam supply Condensate return Outlet Condensate riser collecting manifold Traced pipe Tracer Spares

Process Temperatures: 101°F to 200°F Convection Tracers Designed for use with medium-low to medium heat transfer requirements, the metallic tracer tube is either bare or covered with a thin, high temperature coating that provides a measure of personnel burn protection without sacrificing thermal performance. Process Temperatures: 101°F to 200°F

Process Temperatures: 151°F to 400°F Conduction Tracers Designed for use when the heat requirements exceed the capabilities of isolated and convection tracers. Conduction tracers are aided by heat transfer compounds that provide excellent heat transfer at a fraction of the cost of a jacketed pipe system while eliminating the possibility of product contamination. A single tracer utilizing heat transfer compound will perform as well as 3 to 5 bare (convection) tracers. Process Temperatures: 151°F to 400°F

Tracer Materials The tracer is selected to fulfill the thermal and installation requirements. The tracer metal should be close to the material of the process pipe to minimize galvanic corrosion. Copper tubing can be used if the saturated steam pressure or the item being traced does not exceed 400°F and there is no corrosion or other deterrent (copper oxide) for using copper. Stainless steel tubing can be used if the saturated steam pressure or the item being traced exceeds 400°F and there is no corrosion or other deterrent (chlorides) for using stainless steel. Carbon steel pipe should NEVER be used. During shutdown periods, air and moisture causes rapid rust and pitting.

AVTR AVTR is the accumulated vertical tracer rise i.e. the sum of all the elevation rises (see Figure 5.1). The AVTR should be limited to 15% of the inlet steam pressure for any steam tracing circuit. For example, with an inlet steam pressure of 50 psig, the AVTR should not exceed 7.5 feet. The AVTR is further reduced by losses due to bends, valves, and fittings in the tracer circuits (see Table 5.2). The resultant losses must be deducted to determine the actual AVTR.

AVTR Example

AVTR Reduction Losses

Insulation Guidelines

Tracer Tubing Installation

Small Diameter Tube Tracing Steam 1/2” or 3/8” tubing 1/2” or 3/8” tubing Steam 1/2” or 3/8” tubing Trap Steam Trap Trap Trap Valves Pumps Instruments Very light condensate loads; small diameter tubing ok Condensate must flow downward by gravity to trap Small diameter tube bends around objects easily Each tracer circuit has separate trap

Process Pipe Tracing Methods Hot product flowing in steel pipe loses heat through insulation Products may solidify as they cool: Plastics solidify at low temperatures Asphalt solidifies at ambient temps Increased viscosity when cooled; won’t flow Sulfur solidifies above 350°F and below 250°F Tracer internal with direct contact with product, potential product contamination Tracer external to and in contact with product pipe under insulation Internal Tracing External Tracing

Process Pipe Tracing Notes: Horizontal No! Metal Strap Vertical Yes! Insulating spacer Notes: Low steam velocity to move condensate; must flow by gravity; don’t use wound tracer on horizontal runs Vertical wound tracer on short runs only Metal straps hold tracer Insulating spacers used if product may char, burn or crystallize with intense heat

Number of ½” Diameter Tracers Product line size Freeze Protection or Product solidification at 32°F - 75°F Product Solidification 75°F – 150°F Product solidification 150°F - 300° F 25 mm, 1" 1 40 mm, 1-1/2" 2 50 mm, 2" 80 mm, 3" 3 100 mm, 4" 150 mm, 6" 200 mm, 8" 250 - 300 mm, 10" - 12" 350 - 300 mm, 14" - 16" 6 350 - 400 mm, 18" - 20" 8 450 - 500 mm, 10

Multiple Tracer Spacing Vertical Horizontal Space evenly at bottom of pipe Evenly spaced around pipe

Tracer Lines! How Long? Condensing steam in small diameter tubing causes pressure drop. To insure enough pressure at the trap to remove condensate, tracer length should be limited. 3/8”, 8 mm 75 ft, 23 m 1/2”, 15 mm 125 ft, 38.5 m 3/4”, 20 mm 150 ft, 46.2 m

Multiple Tracing Traps No! Multiple circuits - 1 trap Do not gang trap! Multiple circuits - multiple traps Yes!

Line Tracing Installation Yes! No! Expansion Loops Flange Loops

Steam Jacketed Pipe Why? Rate of heat transfer = f((T1 - T2), Cf) Insulation Steam Jacket Pipe Steam Jacket Product Pipe Product T2 T1 Why? Rate of heat transfer = f((T1 - T2), Cf) Steam temperature close to product temperature Product has low coefficient of heat transfer

Steam Jacketed Installation Steam in Trap Pitch Steam flow counter to product flow Pitch in direction of steam flow Section <= 20 ft. 6 m Moderate climates Trap every 80 to 100 ft, 24 to 30 m Severe climates Trap every 40 ft, 12 m Ideal ! OK ! No !

Jacketed Line Sizing

Steam Tracing Condensate Q = L x A x U x (t1 – t2) x E/(H x N) Q = Condensate load, lb/hr, kg/hr L = Length of tracer, ft, m U = Heat transfer coefficient pipe to air, btu/hr/deg f/sq ft, t1 = Product temperature, °F, t2 = Minimum air temperature °F, E = 1 – insulation efficiency/100 A = Area of pipe per ft length, sq ft/ft, H = Latent heat of steam btu/lb, N = Number of tracers Example: 20” pipe, 200 °F product, -20 °F air, 100 psig steam Q = 125 x 1.93 x 12 x (200-(-20)) x .25/(880 x 4) = 45 lb/hr per tracer