Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left.

Slides:



Advertisements
Similar presentations
Control of ventricular unloading using an electrocardiogram-synchronized Thoratec paracorporeal ventricular assist device  Raffael Amacher, MSc, Alberto.
Advertisements

Max B. Mitchell, MD  The Journal of Thoracic and Cardiovascular Surgery 
Of mice and men and surgical transcatheter aortic valve insertion
Lost in translation The Journal of Thoracic and Cardiovascular Surgery
Manuel J. Antunes, MD, PhD, DSc 
Aortic valve replacement in low-flow, low-gradient aortic stenosis: Left ventricular ejection fraction matters  Victor Dayan, MD, PhD, Philippe Pibarot,
Long-term mechanical circulatory support: A new disease state?
Endoscopic Robotic Mitral Valve Surgery
Hemodynamic effects of partial ventricular support in chronic heart failure: Results of simulation validated with in vivo data  Deborah Morley, PhD, Kenneth.
The RECOVER I: A multicenter prospective study of Impella 5
Weaning of rotary blood pump recipients after myocardial recovery: a computer study of changes in cardiac energetics  Heinrich Schima, PhD, Michael Vollkron,
Effects on pre- and posttransplant pulmonary hemodynamics in patients with continuous-flow left ventricular assist devices  Ranjit John, MD, Kenneth Liao,
Murray H. Kwon, MD  The Journal of Thoracic and Cardiovascular Surgery 
Intrinsic cardiac stem cells are essential for regeneration
Form ever follows function
Suyog A. Mokashi, MD, Lawrence S. Lee, MD, Jan D
Aortic valve implantation with the CoreValve ReValving System via left carotid artery access: First case report  Thomas Modine, MD, Gilles Lemesle, MD,
Resuscitation practices in cardiac surgery
Bicuspid aortic valve aortopathy: One size fits all?
Jennifer S. Lawton, MD, Nader Moazami, MD, Michael K
In vitro hemodynamic characterization of HeartMate II at 6000 rpm: Implications for weaning and recovery  Gengo Sunagawa, MD, Nicole Byram, BS, Jamshid.
Intra-aortic balloon pump therapy negatively affects flow through a continuous-flow left ventricular assist device  Dipanjan Banerjee, MD, MS, Chun Choi,
The engineer and the clinician: Understanding the work output and troubleshooting of the HeartMate II rotary flow pump  W. Scott Arnold, MD, Kevin Bourque,
Use of continuous flow ventricular assist devices in patients with heart failure and a normal ejection fraction: A computer-simulation study  Francesco.
Control of ventricular unloading using an electrocardiogram-synchronized Thoratec paracorporeal ventricular assist device  Raffael Amacher, MSc, Alberto.
The lord of the rings  Antonio Miceli, MD, PhD 
Historical perspectives of The American Association for Thoracic Surgery: George P. Muller, MD, ScD ( )  Richard N. Edie, MD  The Journal of Thoracic.
Expanding left ventricular assist device use to patients with disabilities: The role of assistive technology  Juan A. Crestanello, MD  The Journal of.
The variability of the mitral valve anatomy and terminology
Discussions in Cardiothoracic Treatment and Care: Mechanical Circulatory Support Left Ventricular Assist Device Therapy for Patients With Advanced Heart.
Intra-aortic balloon pumps and continuous flow left ventricular assist devices: Don't let balloon pumps overstay their welcome  Kevin G. Soucy, PhD, Steven.
Innovation and science: The future of valve design
It's not “just a shunt” but sometimes it should be…
Michele Gallo, MD, Gino Gerosa, MD 
Right ventricular failure after cardiac surgery: Why can't right ventricular assist device support fix the problem?  Francis D. Pagani, MD, PhD  The Journal.
Transcatheter aortic valve replacement and surgical aortic valve replacement: Both excellent therapies  J. James Edelman, MBBS(Hons), PhD, Vinod H. Thourani,
Durability of left ventricular assist devices: Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) 2006 to 2011  William L.
Mark S. Slaughter, MD, Guruprasad A
Surgery for aortic and mitral valve disease in the United States: A trend of change in surgical practice between 1998 and 2005  Scott D. Barnett, PhD,
Guruprasad A. Giridharan, PhD, Steven C
Navin K. Kapur, MD, Jenica Upshaw, MD, Michael S
Fenton H. McCarthy, MD, MS, Nimesh D. Desai, MD, PhD 
Sinus of Valsalva aneurysms: Stabilizing the repair destabilizing the aortic valve?  M. Sertaç Çiçek, MD, FACC  The Journal of Thoracic and Cardiovascular.
Leora B. Balsam, MD, Abe DeAnda, MD 
Left atrial pressure measurement in a rat is currently impossible due to size limitations of balloon occlusion catheter  Filip Konecny, MSc, DVM, PhD 
Replicating the success of mitral valve repair in the aortic valve
Instrumental variable methods in clinical research
Passing the torch The Journal of Thoracic and Cardiovascular Surgery
Patrick T. Roughneen, MD, Grant T. Fankhauser, MD, Abe DeAnda, MD 
Hans-Joachim Schäfers, MD 
The origins of open heart surgery at the University of Minnesota 1951 to 1956  Richard A. DeWall, MD  The Journal of Thoracic and Cardiovascular Surgery 
Early extubation after cardiac surgery: The evolution continues
The Journal of Thoracic and Cardiovascular Surgery
Discussion The Journal of Thoracic and Cardiovascular Surgery
The future of cardiac surgery training: A survival guide
Ventricular assistant in restrictive cardiomyopathy: Making the right connection  Robert D.B. Jaquiss, MD  The Journal of Thoracic and Cardiovascular Surgery 
Between a rock and a hard place
Cerebrovascular accidents in patients with a ventricular assist device
Seeing is believing: A call for routine early postoperative hemodynamic transesophageal echocardiography monitoring after left ventricular assist device.
Vinay Badhwar, MD, John S. Ikonomidis, MD, PhD, Jeffrey P. Jacobs, MD 
“The more things change…”: The challenges ahead
Toward a more rational approach in treating type B aortic dissection
Gastrointestinal bleeding after left ventricular assist device implantation: It is all about the platelets  Juan A. Crestanello, MD  The Journal of Thoracic.
Investigation of hemodynamics in an in vitro system simulating left ventricular support through the right subclavian artery using 4-dimensional flow magnetic.
Journal changes and initiatives
Hari R. Mallidi, MD  The Journal of Thoracic and Cardiovascular Surgery 
Lessons learned from Melody valve retrieved at transplantation
Zone zero thoracic endovascular aortic repair is all about “location, location, location”  Kevin L. Greason, MD  The Journal of Thoracic and Cardiovascular.
Cavoaortic shunt improves hemodynamics with preserved oxygen delivery in experimental right ventricular failure during left ventricular assist device.
Deciding how much to pay for effective care
Presentation transcript:

Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model  George V. Letsou, MD, Thomas D. Pate, MS, Jeffrey R. Gohean, MS, Mark Kurusz, BA, CCP, Raul G. Longoria, PhD, Larry Kaiser, MD, Richard W. Smalling, MD, PhD  The Journal of Thoracic and Cardiovascular Surgery  Volume 140, Issue 5, Pages 1181-1188 (November 2010) DOI: 10.1016/j.jtcvs.2010.03.043 Copyright © 2010 The American Association for Thoracic Surgery Terms and Conditions

Figure 1 Schematic of the experimental preparation and instrumentation. LVV, Left ventricular volume crystals; LVP, left ventricular pressure micromanometer; QVAD, VAD flow probe; LAP, left atrial pressure catheter; QAo, aortic flow probe; AoP, aortic pressure micromanometer; CVP, central venous pressure catheter. The Journal of Thoracic and Cardiovascular Surgery 2010 140, 1181-1188DOI: (10.1016/j.jtcvs.2010.03.043) Copyright © 2010 The American Association for Thoracic Surgery Terms and Conditions

Figure 2 Hemodynamic recordings obtained from pig 14 during baseline (A), with LAD ligation and acute LV failure (B), with TORVAD (Windmill Cardiovascular Systems, Inc, Austin, TX) support during failure (C), and with BioMedicus (Medtronic, Inc, Minneapolis, MN) support during failure (D). AOP, Aortic pressure; LV, left ventricular; LVP, left ventricular pressure; LAP, left atrial pressure; QAO, transaortic valve flow; QVAD, ventricular assist device output. The Journal of Thoracic and Cardiovascular Surgery 2010 140, 1181-1188DOI: (10.1016/j.jtcvs.2010.03.043) Copyright © 2010 The American Association for Thoracic Surgery Terms and Conditions

Figure 3 Cardiac output (A), aortic valve flow (B), mean LAP (C), and MAP (D) with LAD ligation during acute LV failure. Measurements were obtained during LV failure after LAD occlusion and then with BioMedicus and TORVAD support in random sequence. The Journal of Thoracic and Cardiovascular Surgery 2010 140, 1181-1188DOI: (10.1016/j.jtcvs.2010.03.043) Copyright © 2010 The American Association for Thoracic Surgery Terms and Conditions

Figure 4 Pressure-volume loops obtained from pig 14 during baseline, with LAD ligation and acute LV failure, with BioMedicus support during failure, and with TORVAD support during failure. LV, Left ventricular; LVP, left ventricular pressure; LVV, left ventricular volume. The Journal of Thoracic and Cardiovascular Surgery 2010 140, 1181-1188DOI: (10.1016/j.jtcvs.2010.03.043) Copyright © 2010 The American Association for Thoracic Surgery Terms and Conditions