A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent  Rachel.

Slides:



Advertisements
Similar presentations
Feasibility of wall stress analysis of abdominal aortic aneurysms using three- dimensional ultrasound  Annette M. Kok, MSc, V. Lai Nguyen, MD, Lambert.
Advertisements

Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for intervention  Greg.
Ultrasound-determined diameter measurements are more accurate than axial computed tomography after endovascular aortic aneurysm repair  Sukgu M. Han,
Annual rupture risk of abdominal aortic aneurysm enlargement without detectable endoleak after endovascular abdominal aortic repair  Dave Koole, MD, Frans.
Erosion of lumbar vertebral bodies from a chronic contained rupture of an abdominal aortic pseudoaneurysm  W. Andrew Oldenburg, MD, Tariq Almerey, MD 
Bare metal stent infections: Case report and review of the literature
Tridirectional phase-contrast magnetic resonance velocity mapping depicts severe hemodynamic alterations in a patient with aortic dissection type Stanford.
Mark J.W. Koelemay, MD, PhD  Journal of Vascular Surgery 
Mural aortic thrombi: An important cause of peripheral embolization
Hemodynamic evaluation using four-dimensional flow magnetic resonance imaging for a patient with multichanneled aortic dissection  Baolei Guo, MD, PhD,
Direct thrombolytic therapy in portal and mesenteric vein thrombosis
Aortic arch involvement worsens the prognosis of type B aortic dissections  R. James Valentine, MD, Julia M. Boll, MD, Kyle M. Hocking, PhD, John A. Curci,
A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging  Rachel E. Clough, MBBS, BSc,
Feasibility of wall stress analysis of abdominal aortic aneurysms using three- dimensional ultrasound  Annette M. Kok, MSc, V. Lai Nguyen, MD, Lambert.
Endovascular repair of descending thoracic aortic aneurysm in patient with Wiskott- Aldrich syndrome  Ragai Reda Makar, MSc, MD, FRCS, Pavels Gordins,
In situ aortic allograft insertion to repair a primary aortoesophageal fistula due to thoracic aortic aneurysm  Laurence Pirard, MD, Etienne Creemers,
Toronto PowerWire fenestration technique to access false lumen branches in fenestrated endovascular aneurysm repair for chronic type B dissection  Steffan.
Amir H. Malkawi, MRCS, Robert J
Aortic disease: The quest to improve patient outcomes
Initial findings and potential applicability of computational simulation of the aorta in acute type B dissection  Zhuo Cheng, PhD, Celia Riga, MRCS, Joyce.
Preliminary findings in quantification of changes in septal motion during follow-up of type B aortic dissections  Christof Karmonik, PhD, Cassidy Duran,
Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for intervention  Greg.
Rachel E. Clough, MB, BS, BSc, MRCS, Jane A. Topple, MB, BS, Hany A
Utility of left subclavian artery revascularization in association with endoluminal repair of acute and chronic thoracic aortic pathology  Brian G. Peterson,
Hemodynamic effect of carotid stenting and carotid endarterectomy
Validation of semiautomated and locally resolved aortic wall thickness measurements from computed tomography  Eric K. Shang, MD, Eric Lai, BS, Alison.
Analysis of aortic wall stress and rupture risk in patients with abdominal aortic aneurysm with a gender perspective  Emma Larsson, MD, Fausto Labruto,
Erosion of lumbar vertebral bodies from a chronic contained rupture of an abdominal aortic pseudoaneurysm  W. Andrew Oldenburg, MD, Tariq Almerey, MD 
Abdominal aortic aneurysm diameter: A comparison of ultrasound measurements with those from standard and three-dimensional computed tomography reconstruction 
Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection  Yong-Lin Qin, MD, Gang.
Ali Khoynezhad, MD, Irwin Walot, MD, Matthew J
Management of common carotid artery dissection due to extension from acute type A (DeBakey I) aortic dissection  Kristofer M. Charlton-Ouw, MD, FACS,
Penetrating ulcer of the thoracic aorta: What is it
Total percutaneous access for endovascular aortic aneurysm repair (“Preclose” technique)  W. Anthony Lee, MD, Michael P. Brown, DO, Peter R. Nelson, MD,
Bare metal stent infections: Case report and review of the literature
Disseminated intravascular coagulation after endovascular aneurysm repair: Resolution after aortic banding  Ashish S. Patel, MRCS (Eng), MBBS (Lond),
Successful treatment of disseminated intravascular coagulation associated with aortic dissection  Masahiko Fujii, MD, Hiroyuki Watanabe, MD, Masayoshi.
The accuracy of computed tomography central luminal line measurements in quantifying stent graft migration  Andrew England, MSc, Marta García-Fiñana,
Use of computational fluid dynamics studies in predicting aneurysmal degeneration of acute type B aortic dissections  Eric K. Shang, MD, Derek P. Nathan,
Laura van Zeggeren, MD, Evert J. Waasdorp, MD, Bart H
Aortic graft infection with enteric organism after embolization of late type II endoleak  Ben Li, BHSc, Kong Teng Tan, MD, Mary Elizabeth MacDonald, MD,
Successful treatment of disseminated intravascular coagulation associated with aortic dissection  Masahiko Fujii, MD, Hiroyuki Watanabe, MD, Masayoshi.
Anthony S. Leicht, PhD, Robert G
Coil embolization of persistent false lumen after stent graft repair of type B aortic dissection  Enrique María San Norberto, MD, Vicente Manuel Gutiérrez,
Reply Journal of Vascular Surgery
Hybrid management of ruptured isolated superior mesenteric artery dissecting aneurysm  Yoshikatsu Nomura, MD, Masato Yamaguchi, MD, Atsushi Kitagawa,
Andres Schanzer, MD, Louis M
The first endovascular repair of an acute type A dissection using an endograft designed for the ascending aorta  Matthew J. Metcalfe, MD, MRCS, Alan Karthikesalingam,
Isolated celiac artery dissection
Thrombotic mesenteric ischemia due to aortic dissection
The role of dynamic contrast-enhanced magnetic resonance imaging in the diagnosis and management of patients with vascular malformations  Michael E. Lidsky,
Ryan M. Gobble, MD, Eliott R. Brill, MD, Caron B
Chronic type B dissecting aortoiliac aneurysm repair complicated by congenital pelvic kidney  Philip Mark Coney, MRCS, Vivek Shanmugan, MRCS, Sudarsanam.
Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting  Carlos H. Timaran, MD, Eric B.
Massive upper gastrointestinal bleeding due to a ruptured superior mesenteric artery aneurysm duodenum fistula  Jichun Zhao, MD, PhD  Journal of Vascular.
Regarding “Lunar cycles and abdominal aortic aneurysm rupture”
Journal of Vascular Surgery
True abdominal aortic aneurysm in Marfan syndrome
Aortic graft infection with enteric organism after embolization of late type II endoleak  Ben Li, BHSc, Kong Teng Tan, MD, Mary Elizabeth MacDonald, MD,
Detection of common carotid artery stenosis using duplex ultrasonography: A validation study with computed tomographic angiography  David P. Slovut, MD,
Sandra A. Cornelissen, MD, MSc, Hence J
Journal of Vascular Surgery
Successful endovascular treatment of hemosuccus pancreaticus due to splenic artery aneurysm associated with segmental arterial mediolysis  Hideaki Obara,
Michael J. Gough, ChM, FRCS  Journal of Vascular Surgery 
Early biomechanical changes in lower extremity vein grafts—distinct temporal phases of remodeling and wall stiffness  Christopher D. Owens, MD, Nicole.
Expansion rates and outcomes for iliac artery aneurysms
Michael P. Jenkins, MD, Stéphan Haulon, MD, PhD, Roy K
Open repair of abdominal aortic aneurysm in a centenarian
Susan Stevenson, MB ChB, Vijay Ramani, MS, Akhtar Nasim, MD 
Matthew Thompson, MD, Peter Holt, PhD, Ian Loftus, MD, Thomas L
Presentation transcript:

A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent  Rachel E. Clough, MB, BS, BSc, Tarique Hussain, MA, MB, BChir, Sergio Uribe, PhD, Gerald F. Greil, MD, Reza Razavi, MB, BS, MD, Peter R. Taylor, MA, MChir, Tobias Schaeffter, PhD, Matthew Waltham, MA, PhD  Journal of Vascular Surgery  Volume 54, Issue 5, Pages 1251-1258 (November 2011) DOI: 10.1016/j.jvs.2011.05.022 Copyright © 2011 Society for Vascular Surgery Terms and Conditions

Fig 1 Bland-Altman plot illustrating the difference in thrombus volume derived from first pass computed tomography (CT) and magnetic resonance imaging (MRI). Good agreement between the two techniques is demonstrated with no proportional bias. Journal of Vascular Surgery 2011 54, 1251-1258DOI: (10.1016/j.jvs.2011.05.022) Copyright © 2011 Society for Vascular Surgery Terms and Conditions

Fig 2 In all patients, the volume of thrombus derived from first pass acquisitions was greater than the volume derived from delayed phase magnetic resonance imaging (MRI) with blood pool agent. The first pass acquisitions overestimated the volume of thrombus by an average of six times. CT, Computed tomography. Journal of Vascular Surgery 2011 54, 1251-1258DOI: (10.1016/j.jvs.2011.05.022) Copyright © 2011 Society for Vascular Surgery Terms and Conditions

Fig 3 First pass images and delayed phase magnetic resonance (MR) images with blood pool agent demonstrating marked difference in contrast enhancement of the false lumen. (i) A, First pass computed tomography (CT); B, corresponding delayed phase MR image with blood pool agent. (ii) A, First pass MR; B, corresponding delayed phase MR image with blood pool agent. Journal of Vascular Surgery 2011 54, 1251-1258DOI: (10.1016/j.jvs.2011.05.022) Copyright © 2011 Society for Vascular Surgery Terms and Conditions

Fig 4 The difference in thrombus volume between first pass and delayed phase magnetic resonance imaging (MRI) with blood pool agent correlated significantly with the mean velocity of flow in the false lumen, with lower flow related to a greater difference. Journal of Vascular Surgery 2011 54, 1251-1258DOI: (10.1016/j.jvs.2011.05.022) Copyright © 2011 Society for Vascular Surgery Terms and Conditions

Fig 5 Areas of thrombus enhancement on DTI were segmented to create a mask, and this was aligned with the delayed phase MR blood pool image data using the global scan coordinates. In all patients, the area of thrombus on direct thrombus images matched the area of contrast absence on delayed phase magnetic resonance (MR) with blood pool agent. A, Direct thrombus image; B, thrombus segmented; C, mask; D, delayed phase MR image with blood pool agent; E, mask from image B aligned with image D using the global scan coordinates. *Area of thrombus. Journal of Vascular Surgery 2011 54, 1251-1258DOI: (10.1016/j.jvs.2011.05.022) Copyright © 2011 Society for Vascular Surgery Terms and Conditions