Harrow Court, Stevenage 2nd Feb 2005

Slides:



Advertisements
Similar presentations
Facilities Management and Design Chapter 4 Safety and Security systems.
Advertisements

It s A Matter of Choice Always …. Jerry is the manager of a restaurant. He is always in a good mood.
CASE STUDY ON BOILER ACCIDENT
Emergency Evacuation Zayed University, Dubai Campus.
Sprinklers – Making the case to Local Government for their installation. Fire Sprinkler International, Grange Tower Bridge Hotel, London 20 th & 21 st.
May 2014 MCO Training:.  Session:  2 Hours  30 minutes class  2 Practice drills  Objectives:  Review RIC and Mayday procedures  Introduce the default.
1 Lincolnshire Fire & Rescue Training Centre FIXED INSTALLATIONS DRY AND WET RISERS COMPETENCE STATEMENT 373.
Air & Smoke Movement in and around High Rise buildings (Air Tracks) Mark Fishlock 2011.
Dealing with Casualties Casualty Care Aim To make students aware of the various types of victims at incidents and the appropriate casualty care.
The two words 'information' and 'communication' are often used interchangeably, but they signify quite different things. Information is giving out; communication.
Harrow Court, Stevenage 2nd Feb 2005
There is growing evidence that torture is still practiced by Israel’s security system during interrogations of Palestinian detainees. This conduct contradicts.
FIREFIGHTER SURVIVAL.
Fire Marshal & Medical Emergency Training Please Sign In
Fire Investigation Aim To introduce students to factors which support incident investigation.
NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS and Special Ops The Right Description.
Retirement Home Regulated under the Retirement Home Act, 2010.
Human behaviour is not an exact science. We all behave differently when faced with situations that are life threatening. However from studies of tragedies.
Lifts and Machinery Rescues Service Delivery 2 Aim To provide students with information to enable them to deal with lift incidents.
Tactics.  Garden Apartments  Town Homes  Apartment Buildings 2.
Organisational Management and Development 2 Incident Command.
PROGRAM OBJECTIVES At the completion of this program, the firefighter will be able to:
For a long time the police thought it was a collision of the underground trains. The police declare the situation as a major incident. At 9.20am the train.
More information can be found on
Staner Court, Manston Road, Ramsgate. Incident number rd July 2001 All comments/observations are made with the benefit of hindsight and non- attendance.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Week 1 Seminar Chapter Firefighter Fatalities in the United States 1.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Maryland FF Fatality October 10, Investigation  NIOSH General Engineer  NIOSH Occupational Safety & Health Specialist  Fire Department Safety.
High Rise October DISPATCH E82, E83, E81, E97, E86, E95, T82, T98, R81, R83, R97, B8, B9, OSO respond to a reported structure fire at 777 W. Lake.
Mine Rescue Practice DK. STATEMENT PROBLEM GENTLEMEN, WE THANK YOU FOR ANSWERING OUR CALL FOR HELP! SEVEN PEOPLE WERE WORKING SATURDAY.
Source: Internet Distribution: Emtedad Engineering Company You have two choices.
Search & Rescue Ins and Outs Presented for use by Emory Arnold For.
Neil Cooper Fire Safety Residential Implementing the Changes.
REPORTED SPEECH OR INDIRECT SPEECH. WHY USE REPORTED SPEECH?  We use REPORTED SPEECH to report the meaning of what was said. Sometimes we report the.
Southeast Financial Center
Low Burning and Holes In The Floor. What is the Myth?  Burn marks on a floor indicate that a fire was set on purpose because…  heat rises  fires only.
1. 2  Dispatch information  Day of week  Time of day  Pre-incident survey  Observations  Building construction, layout  Bystanders.
What are the New Safety Mandates? Presented by Mark Schaudt.
Week 1 Seminar Firefighter Fatalities in the United States.
13 Search and Rescue.
PERFORM THE TASKS AND FULFILL THE RESPONSIBILITIES OF RANGE PERSONNEL PO/EO: REF.: B-GL /TS-000, TRAINING SAFETY.
Using existing lifts in existing buildings to evacuate disabled persons Derek Smith Technical Director UK Lift and Escalator Industry Association.
Fire Ground Roles & Responsibilities On scene reports & Truck and seat assignments.
WEAR ALL YOUR GEAR. NO EXPOSED SKIN. NO EXCUSES
Safe, Well And Independent Living Project Co-ordinator
Southeast Financial Center
Theme Park Ride Crash Disclaimer: this safety moment is designed to prevent similar incidents occurring. All guidance herein is provided in good faith.
ENGELSK Fire safety in the home brannvernforeningen.no.
Driver Exits Burning Semi-Truck and Falls to His Death
CASE STUDY ON BOILER ACCIDENT
HOARDING & DWFire.
Tyne and Wear Fire and Rescue Service
Lessons From Emergency Services
F* India F W Training.
February Monthly Training May Day & Emergency Communications
Building and Fire Codes
WEAR ALL YOUR GEAR. NO EXPOSED SKIN. NO EXCUSES
Marston Road, Stafford Incident Case Study
Unit 5 Reading Period (1) A brave young man.
Lou Contralto Exhibit 5 Exhibit 6
(Begin DE Assignment – Forensic Pathology)
WEAR ALL YOUR GEAR. NO EXPOSED SKIN. NO EXCUSES
Unit 5 Reading Period (1) A brave young man.
You have two choices.
You have two choices.
You have two choices.
It’s A Matter of Choice Always…
Fire Safety City Campus
Presentation transcript:

Harrow Court, Stevenage 2nd Feb 2005 Ff Jeffery Wornham Ff Michael Miller All information passed in this presentation is an accumulation of research carried out by myself. It is a conglomeration of data from the formal Inquiry/Inquest and personal accounts / conversations of those attending. It passes no judgement on those dealing with the incident and recognises and applauds the courage and bravery of all those that attended. M Fishlock

Location (2 mins)

Normal “H” pattern residential tower block. System build - Concrete Building Normal “H” pattern residential tower block. System build - Concrete

Building 18 Story, 103 Flats. Low Socio-economic population

Background One of a set of 2 Twin blocks Built in late 60’s Regular calls to AFA call point. Rubbish/Rubbish chutes alight. No serious fires in last 10 years Not special risks. Not on 11(D) / 7.2(D) Dry riser (4”) to all floors 2 Lift shafts (single carriage)

Floor plan

INCIDENT 02:58 FIRST 999 Fire on 15th Floor, Flat 89 03:00 MOB 2 Pumps from Stevenage to Persons Reported 03:00 Manual CP activated 3:02 Pumps book MI 3:03 IA Crews see smoke issuing

3:03 T/LFF Antrobos is met by other building occupants and confirm fire is actually in F85 on 14th Floor 3:04 LFF Scotchford instructs T/LFF A and crew (Ff Miller, Wornham) “Hang on and Do not go up!” But they proceed up and LFf S radios them to tell him what’s happening. FF Dudly expresses concerns that they have gone up. FF Dudly, FF Dredge, FF Boswell form second crew and collect equipment ready in lift lobby FF Wornham (now in the lift ) has forgotten his helmet and uses T/Lff A’s Witness statements confirm that FF Dudly was complaining that the crews should have waited in the lobby

3:05 light smoke observed from top of door to F85 BA Crew commits (no EC procedure no Water ) T/LFF A sets in hose from DR but its chained & Padlocked. She orders it charged and asks for bolt croppers. Screaming (Male) is heard from flat 85 3:06 BA Crew commit & rescue Mr Savage from F85 they are told his Girlfriend is still in the flat

Approx 3:07 from CCTV

3:07 External signs of rapid fire smoke development. MP4 3:08 second BA crew meet with TLff/A by DR outlet. DR is charged but still chained shut. Lifts are being affected by smoke 3:09 TLFF A States that she declares a “BA EMERGENCY” not received or acknowledged LFF S arrives at 14th floor and 2nd BA crew commits into a “Serious fire” 3:12 2nd BA crew withdraw after one loses his helmet. FF Wornham is believed to leave the flat and becomes entangled in cables in lobby.

3:13 14 th floor lobbies smoke logged 3:15 T/LLF A Meets DO Drakes in lift lobby, tells him she’s declared a BA Emergency. 3:17 BA Crew 2 have recommitted and are trying to recue FF W but beaten back by heat (they still have no water) 3:20 MP8 BA Emergency message sent

3:23 4 ba wearers drag FF W into stairwell lobby (still entangled) 3:25 using personal knifes and axe, cables are freed from FF W Hose line from 13th floor extended into flat 85, Fire described as “like a jet engine” by BA teams

3:30 BA teams discover FF M and female occupant in Bedroom2 Both Obviously deceased and bodies are left in situ.3:30 Fire spread to 15th floor 3:46 FFW taken out of building on stretcher 3:50 MSG: “1 FF & 1Female believed dead MP10”

4:01 MSG “2 civilians dead, left in situ” 4:05 ACO books IA 4:49 ACO MSG “ 1 FF and 2 civilians fatal” 6:00 ACO MSG “” fire-fighters and 1 Female civilian confirmed fatal. 1 FF in hospital suffering burns, 70 persons lead to safety, all persons accounted for” 7:08 stop.

Cause: TEALIGHT candles on TV set 14th Feb 2003 BRE researched and recreated the fire 180c to 800c flashover developed 60 seconds after opening the recreated bedroom. 83 recommendations from enquiry

Recommended reading HFRS Investigation FBU Response to Investigation Euro fighter (Paul Grimwood)

THANKS KFRS Thames Gateway Regional forum (High Rise) HFRS FBU BRE Martin Arrowsmith (Welwyn Garden City. HFRS) Paul Grimwood (expert witness at Coroners inquest) LFB High Rise Working group ANY QUESTIONS?