OWNER – WAPITI CONSULTING, LLC.

Slides:



Advertisements
Similar presentations
Groundwater What is it and why is it important?
Advertisements

The value in mechanical & electrical retrofits What Pays and what Doesnt? What Pays and what Doesnt? June 16, 2011 June 16, 2011 Mark Kesseler Mark Kesseler.
PRESENTERS NDENGA D.L,ASSOCIATED BATTERY MANUFACTURERS,NAIROBI AND KILONZI F.M,MOI UNIVERSITY,ELDORET. APPLICATION OF PINCH TECHNOLOGY IN MINIMISATION.
Geothermal Power Matthew Duarte Josh Ku-ha! Jerry Lu.
 Solar energy is the result of thermonuclear fusion reactions deep within the sun.  Solar energy is the most abundant and most powerful energy source.
Geothermal HVAC for Homes, Farms and Businesses (and schools) Alice Gitchell Richard Stockton College Please feel free to ask questions at any time!
Geothermal Heat Pumps in residential and commercial HVAC systems Dan Winters 4/18/11.
How to Build a Groundwater Model Activity Source Created by the USA Groundwater Foundation; modified from the Science Olympiad event, Awesome Aquifers.
Aquifer Storage & Recovery Projects Utah Water Users Workshop March 18, 2014 Kurt Vest, P.E. Region Engineer.
©2005 Armstrong International, Inc. Open and Closed Systems.
Increasing the energy efficiency of buildings Chris Cirone PhD Candidate, Agricultural and Biological Engineering.
PENTAIR 1.
Irrigation Pumping Plants By Blaine Hanson University of California, Davis.
Richard Simmons Drilling Company, Inc. 60 Drill Rig Drive, Buchanan, Virginia Telephone (540) Geothermal Heating & Cooling How it Works.
Lecture 30 Heat Pump Systems.
1 Xcel Energy Webinar October 24, :30 am to 1:00 pm CT VFDs Drive Efficiency: Learn how Variable Frequency Drives can benefit your facility.
Marie Zubatá 3. A.  Centrifugal pumps are a type pumps used to convey liquids or gases by the means of a rotating impeller, which increases the pressure.
NH Utilities Programs/ Carbon Reduction Opportunities Thomas Palma, Esq., CSDP Project Development Executive.
Power off the Grid 4. The Net Zero Energy Home Produces as much electricity (energy) as it uses. Net metering is needed to monitor energy generated by.
2 Located within the Naval Petroleum Reserve No.3 (NPR-3), RMOTC –Operates in an oil field environment –Explores solutions to energy issues –Demonstrates.
POWER SAVING BY ROCKSOLID INDUSTRIAL SOLUTIONS SYSTEMS REQUIRING PUMPS USING VALVE CONTROL SYSTEMS REQUIRING FANS USING DAMPER CONTROL SAVE GOOD $MONEY$
Converting a supply well into an ASR well: Case Histories Roger Dittus PG – United Water Idaho Inc.
PLATFORM UTILITIES PAB 2073 Reference: PCSB/PMO document.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
ENERGY.
Page  1 Reverse Osmosis Electro-dialysis Sources of brine Water pollution by industrial brines Background BRINE TREATMENT USING FREEZE DESALINATION TECHNOLOGY.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Group 17 Oceanic Thermal Energy Conversion Model - Lockheed Martin 1 Oceanic Thermal Energy Conversions Group Members: Brooks Collins Kirby Little Chris.
WATER RESOURCE DEVELOPEMENT Prepared By: (Group-3)  Vadlani Ronak  Patel Shivanshu  Patel Parth  Thaker Rajvi  Leuva Nisarg  Patel Rudra ALPHA COLLEGE.
Developing Green Stormwater Design Solutions For UIC Compliance Presented by: Adam Zucker PE, CWRE 819 SE Morrison Street ● Suite 310 ● Portland, Oregon.
7154 VFD Presentation #5 June 2002 Paul Weingartner.
Water Source.  SC has no requirements to be an irrigation contractor  Other states do NC to be certified NC to be certified.
Renewables and System Services Ann Scully.
Geothermal Energy Braden and Matthew.
The Natural Hydrologic Cycle and The Synthetic Hydrologic Cycle What goes around, comes around.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
IMPROVING THE EFFICIENCY GEOTHERMAL or GROUND SOURCE HEAT PUMPS.
Energy Saving Measures - 1
RENEWABLE ENERGY WIND, SOLAR AND GEOTHERMAL
Decentralised Treatment & Re-use Saudi Water & Energy Forum Jeddah, October 12 th – 14 th 2009 Paul O’Callaghan
Energy System Design: A Look at Renewable Energy Summary Lecture.
WaterSilos The Ultimate Storage Solution
Compressed Air Energy Storage (CAES) Wind Integration Study Team September 10, 2009.
WASTEWATER TREATMENT PETRIT TARE GENERAL DIRECTOR OF UKKO JSC CONFORMING TO EU WASTEWATER TREATMENT DIRECTIVE CASE STUDY OF KORCA CITY, ALBANIA.
ALSI Air and Liquid Systems, Inc. CheckMark vs. Centrifuge.
SUDHIR REDDY S.V.R M.TECH(CAD/CAM)
Solar Pumps- High profitability and reliability lead to prosperity.
Chapter 21 Water Supply, Use and Management. Groundwater and Streams Groundwater –Water found below the Earth’s surface, within the zone of saturation,
Comprehensive Energy Projects May 4, 2016 Andy Kelly Manager of Plant Engineering Central Production Facility Co-op & Northeast Hot Fill Co-op.
Sanitary Engineering Lecture 8. Water Reuse Water reuse describes the process whereby wastewater (it's include storm water which is a term used to describe.
Renewable Energy Wind, Solar and Geothermal
Irrigation Pumping Plants
Utility Bills Reduction by Energy Consumption Management
Date of download: 10/6/2017 Copyright © ASME. All rights reserved.
Plug-in to the Future of Hybrids
Energy Savings Projects
Variable Frequency Drive Savings Calculator Tools
Ocean thermal energy conversion (OTEC)
Outline of Presentation
Different scales of installation
Module 39 Solar, Wind, Geothermal, and Hydrogen
Garrett County Public Works Utilities Division
Carlos S. Aguirre & Thuy Vu, Ph.D Department of Civil Engineering
Energy Efficiency in District Coiling System
BASIC MECHANICAL ENGINEERING
NET-ZERO-ENERGY (NZE) WASTEWATER TREATMENT PLANTS (WWTPs)
Summary Water is a renewable resource that circulates continually between the atmosphere and the Earth’s surface. The energy for the hydrologic cycle is.
Lecture 30 Heat Pump Systems.
Presented by Mike Zacharias
Energy Management Introduction Rantharu Attanayake BSc. (Eng), MSc, MBA EE – Energy Management Mobile :
Presentation transcript:

OWNER – WAPITI CONSULTING, LLC. ASR GENERATION: GENERATING POWER DURING THE INJECTION CYCLE OF AN ASR PROJECT PRESENTED BY: KENT MADISON OWNER – 3R VALVE, LLC & MATTHEW JOHNSON, P.E. OWNER – WAPITI CONSULTING, LLC.

WHAT IS AR AND ASR? Aquifer recharge (AR) and aquifer storage and recovery (ASR) are manmade processes or natural processes enhanced by humans that convey water underground. The processes replenish ground water stored in aquifers for beneficial purposes. Although AR and ASR are often used interchangeably, they are separate processes with distinct objectives. AR is used solely to replenish water in aquifers. ASR is used to store water, which is later recovered for use. www.epa.gov/uic/aquifer-recharge-and-aquifer-storage-and-recovery

AR AND ASR POWER REGENERATION During aquifer recharge or aquifer storage process, the pumping motor is allowed to run in reverse therefore converted to a generator. Works in both submersible pumps and above ground vertical line shaft applications. Motor starting requirements: VFD (Variable Frequency Drive), Soft Starter, Across the Line Power regeneration requirements: VFD (Variable Frequency Drive) Regeneration Drive

BENEFITS OF AR AND ASR POWER REGENERATION DURING AQUIFER INJECTION Reduce net kilowatt hours paid for pumping municipal, industrial or agricultural water. Reduce consumer electrical grid footprint. Existing installations have shown a quick payback on capital investments. Overall public perception. Possible utility credit.

REGENERATION EXAMPLE 1 : AQUIFER INJECTION MOTOR STARTER (VFD) MOTOR STARTER (VFD) UTILITY POWER REGERATION VFD WELL PUMP WELL PUMP SHALLOW AQUIFER CONSUMER DEEP AQUIFER

REGENERATION EXAMPLE 1 : AQUIFER RECOVERY MOTOR STARTER (VFD) UTILITY POWER REGERATION VFD WELL PUMP WELL PUMP SHALLOW AQUIFER CONSUMER DEEP AQUIFER

REGENERATION EXAMPLE 2 : AQUIFER INJECTION MOTOR STARTER (VFD) UTILITY POWER REGERATION VFD WELL PUMP WASTEWATER SECONDARY TERTIARY TREATMENT WATER CONSUMER DEEP AQUIFER

REGENERATION EXAMPLE 2 : AQUIFER RECOVERY MOTOR STARTER (VFD) UTILITY POWER REGERATION VFD WELL PUMP WASTEWATER SECONDARY TERTIARY TREATMENT WATER CONSUMER DEEP AQUIFER

REGENERATION EXAMPLE 3 : AQUIFER INJECTION MOTOR STARTER (VFD) MOTOR STARTER (VFD) UTILITY POWER REGERATION VFD WELL PUMP WATER TO AIR HEAT EXCHANGER IN AC MODE COLD AQUIFER WARM AQUIFER

REGENERATION EXAMPLE 3 : AQUIFER RECOVERY MOTOR STARTER (VFD) MOTOR STARTER (VFD) POWER REGERATION VFD UTILITY WELL PUMP WATER TO AIR HEAT EXCHANGER IN HEATING MODE COLD AQUIFER WARM AQUIFER

REGENERATION EXAMPLE 4 : AQUIFER INJECTION MOTOR STARTER (VFD) ASR VALVE OPEN 1-50 % SPIN MOTOR UTILITY POWER REGERATION VFD ASR VALVE OPEN 51-100 % SPIN MOTOR & AQUIFER INJECTION WASTEWATER SECONDARY TERTIARY TREATMENT WATER WELL PUMP CONSUMER DEEP AQUIFER

REGENERATION EXAMPLE 4 : AQUIFER RECOVERY MOTOR STARTER (VFD) UTILITY POWER REGERATION VFD ASR VALVE CLOSED 100 % FOR PUMPING (RECOVERY) WASTEWATER SECONDARY TERTIARY TREATMENT WATER WELL PUMP CONSUMER DEEP AQUIFER

MADISON FARMS ECHO, OREGON ASR REGENERATION 200 HP MOTOR WITH VERTICAL LINE SHAFT PUMP – 8” PIPE, AQUIFER LEVEL 520 FEET BELOW LAND SURFACE. 200 HP MOTOR STARTING VFD & 100 HP REGENERATION VFD WITH LOCAL CONTROL PANEL.

200 HP MOTOR STARTING DRIVE (VFD) – RIGHT 100 HP POWER REGENERATION DRIVE (VFD) - LEFT

MADISON FARMS : SHALLOW WELL AND DEEP WELL ASR REGENERATION

LOCAL CONTROL PANEL HMI SCREEN NO. 1

LOCAL CONTROL PANEL HMI SCREEN NO. 2

LOCAL CONTROL PANEL HMI SCREEN NO. 3

CITY OF PENDLETON,OREGON WELL NO. 14 100 HP MOTOR 100 HP VFD STARTER 100 HP VFD REGENERATION DRIVE 12” PIPING AQUIFER LEVEL 277 FEET BELOW LAND SURFACE WELL DATA PROVIDED BY TIM SMITH WATER DEPARTMENT SUPERINTENDENT

CONCLUSIONS ASR POWER REGENERATION HAS THE ABILITY TO RECOVER OR RECAPUTURE CAPITAL INVESTMENTS. ASR POWER REGENERATION IS A VALUED INVESTMENT FOR ANY NEW OR EXISTING ASR WELL SITE. ASR POWER REGENERATION WILL REDUCE THE TOTAL POWER CONSUMPTION WHEN USED WITH ADDITIONAL LOADS.

QUESTIONS OR COMMENTS? KENT MADISON 3R VALVE, LLC WWW.3RVALVE.COM KMADISON@EONI.COM (541) 571-0581 MATTHEW JOHNSON, P.E. WAPITI CONSULTING, LLC WWW.WAPITI-CONSULTING.COM 208WAPITICONSULTING@GMAIL.COM (208) 651-1120