Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs 

Slides:



Advertisements
Similar presentations
Cardiac output can be measured with the transpulmonary thermodilution method in a paediatric animal model with a left-to-right shunt  A. Nusmeier, W.P.
Advertisements

Comparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in.
Validation of non-invasive arterial pressure monitoring during carotid endarterectomy  J.F. Heusdens, S. Lof, C.W.A. Pennekamp, J.C. Specken-Welleweerd,
Five algorithms that calculate cardiac output from the arterial waveform: a comparison with Doppler ultrasound  J. Zhang, L.A.H. Critchley, L. Huang 
When fasted is not empty: a retrospective cohort study of gastric content in fasted surgical patients†   P Van de Putte, L Vernieuwe, A Jerjir, L Verschueren,
Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other.
Adverse event reporting tool to standardize the reporting and tracking of adverse events during procedural sedation: a consensus document from the World.
A. Butwick, G. Hilton, B. Carvalho  British Journal of Anaesthesia 
Reduction in mortality after epidural anaesthesia and analgesia in patients undergoing rectal but not colonic cancer surgery: a retrospective analysis.
Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe pre-eclampsia  R.A. Dyer, J.L. Piercy,
Is comparison of changes in cardiac output, assessed by different methods, better than only comparing cardiac output to the reference method?  N.W.F.
Comparison of haemoglobin measurement methods in the operating theatre
Determination of cardiac output by ultrasound dilution technique in infants and children: a validation study against direct Fick principle  M. Boehne,
Parkinson's disease and anaesthesia
Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage† 
M. Niesters, R. Mahajan, E. Olofsen, M. Boom, S. Garcia del Valle, L
M. Klein, L. Minkovich, M. Machina, M. Selzner, V. N. Spetzler, J. M
Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients  F. Franchi, R.
Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery  M.O. Fischer, R. Avram, I. Cârjaliu, M. Massetti,
Influence of lung injury on cardiac output measurement using transpulmonary ultrasound dilution: a validation study in neonatal lambs  S.L. Vrancken,
Accuracy and precision of the ultrasound cardiac output monitor (USCOM 1A) in pregnancy: comparison with three-dimensional transthoracic echocardiography 
Prediction of arterial oxygen partial pressure after changes in FiO2: validation and clinical application of a novel formula†  H.M. Al-Otaibi, J.G. Hardman 
Measurement of functional residual capacity by modified multiple breath nitrogen washout for spontaneously breathing and mechanically ventilated patients 
B. Saugel, M. Cecconi, J.Y. Wagner, D.A. Reuter 
Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques  A.L. Balogh, F. Petak, G.H. Fodor, J. Tolnai,
Secondary spread of caudal block as assessed by ultrasonography
E. Weiss, E. Gayat, V. Dumans-Nizard, M. Le Guen, M. Fischler 
Evaluation of surgical conditions during laparoscopic surgery in patients with moderate vs deep neuromuscular block  C.H. Martini, M. Boon, R.F. Bevers,
J. Thai, E. J. Reynolds, N. Natalia, C. Cornelissen, H. J. M
Less invasive determination of cardiac output from the arterial pressure by aortic diameter-calibrated pulse contour  J.B. de Vaal, R.B.P. de Wilde, P.C.M.
O. Thom, D. M. Taylor, R. E. Wolfe, J. Cade, P. Myles, H. Krum, R
Comparison of two versions of the Vigileo-FloTrac™ system (1. 03 and 1
Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery.
The trend interchangeability method
Anticipating guidelines for ultrasound-guided arterial catheterization
Accuracy of non-invasive measurement of haemoglobin concentration by pulse co- oximetry during steady-state and dynamic conditions in liver surgery  J.J.
C. Hällsjö Sander, M. Hallbäck, M. Wallin, P. Emtell, A. Oldner, H
A. Absalom, D. Amutike, A. Lal, M. White, G.N.C. Kenny 
Transpulmonary thermodilution cardiac output measurement is not affected by severe pulmonary oedema: a newborn animal study  A Nusmeier, S Vrancken, W.P.
Continuous non-invasive cardiac output monitoring during exercise: validation of electrical cardiometry with Fick and thermodilution methods  Y.H. Liu,
J.B. Whiteside, D Burke, J.A.W. Wildsmith 
Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care  B. Bataille, M. Bertuit, M. Mora,
A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients†  J.R.C. Jansen, J.J. Schreuder,
R Kruisselbrink, C Arzola, T Jackson, A Okrainec, V Chan, A Perlas 
Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states  S. Scolletta, S.M. Romano, B. Biagioli,
J.M. van Schalkwyk, D. Lowes, C. Frampton, A.F. Merry 
The output of two sevoflurane vaporizers in the presence of helium
Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the.
Distraction and interruption in anaesthetic practice
Ultrasound-guided central venous catheterization in the prone position
E. Saraceni, S. Rossi, P. Persona, M. Dan, S. Rizzi, M. Meroni, C. Ori 
Similarity between the suprasystolic wideband external pulse wave and the first derivative of the intra-arterial pulse wave  R.A. Payne, D. Isnardi, P.J.D.
Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study  R. Saxena, A. Durward, N.K. Puppala,
Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes 
Bibliometrics of anaesthesia researchers in the UK
Increase in endogenous erythropoietin synthesis through the normobaric oxygen paradox in cardiac surgery patients  Y. Ciccarella, C. Balestra, J. Valsamis,
Pulmonary blood volume measured by contrast enhanced ultrasound: a comparison with transpulmonary thermodilution  I.H.F. Herold, M.A. Soliman Hamad, H.C.
Validity of the 6 min walk test in prediction of the anaerobic threshold before major non- cardiac surgery  R.C.F. Sinclair, A.M. Batterham, S. Davies,
Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery  S.H. Kim, S.Y. Park, J.
Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy  S. Metzelder,
ICU fire evacuation preparedness in London: a cross-sectional study
Suspected opioid-induced hyperalgesia in an infant
Accuracy of impedance cardiography for evaluating trends in cardiac output: a comparison with oesophageal Doppler  E. Lorne, Y. Mahjoub, M. Diouf, J.
H-indices in a university department of anaesthesia: an evaluation of their feasibility, reliability, and validity as an assessment of academic performance 
Ability of esCCO to track changes in cardiac output†
Non-invasive measurement of pulse pressure variation and systolic pressure variation using a finger cuff corresponds with intra-arterial measurement 
Emerging modes of ventilation in the intensive care unit
Voltage changes in the lithium dilution cardiac output sensor after exposure to blood from horses given xylazine  T.D. Ambrisko, Y. Moens  British Journal.
C.M. Chalmers, A.M. Bal  British Journal of Anaesthesia 
H.A. Leather, P.F. Wouters  British Journal of Anaesthesia 
Presentation transcript:

Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs  S.L. Vrancken, W.P. de Boode, J.C. Hopman, S.K. Singh, K.D. Liem, A.F. van Heijst  British Journal of Anaesthesia  Volume 108, Issue 3, Pages 409-416 (March 2012) DOI: 10.1093/bja/aer401 Copyright © 2012 The Author(s) Terms and Conditions

Fig 1 Schematic set-up of CO measurement with TPUD (reproduced with kind permission of Wolters Kluwer Health, from Krivitski and colleagues).19 British Journal of Anaesthesia 2012 108, 409-416DOI: (10.1093/bja/aer401) Copyright © 2012 The Author(s) Terms and Conditions

Fig 2 Study protocol. Circles indicate the timing of three consecutive paired CO measurements. British Journal of Anaesthesia 2012 108, 409-416DOI: (10.1093/bja/aer401) Copyright © 2012 The Author(s) Terms and Conditions

Fig 3 The Bland–Altman plot for the comparison of CO measurements with TPUD (COtpud) and the flow probe around the pulmonary artery (COufp). The solid line represents mean bias and the dotted lines represent LOA for all data. British Journal of Anaesthesia 2012 108, 409-416DOI: (10.1093/bja/aer401) Copyright © 2012 The Author(s) Terms and Conditions

Fig 4 Polar plot representing the changes in CO measured with TPUD (COtpud) and the ultrasound flow probe around the main pulmonary artery (COufp) with open shunt and closed shunt. Dotted lines represent the 10% boundaries (i.e. 10%=0.1 litre min−1 as mean CO=1.0 litre min−1). The distance from the centre of the plot (vector) represents the mean change in CO. The angle with the horizontal (0° radial) axis represents disagreement. British Journal of Anaesthesia 2012 108, 409-416DOI: (10.1093/bja/aer401) Copyright © 2012 The Author(s) Terms and Conditions

Fig 5 Examples of TPUD curves (green) without (a) and with (b) a left-to-right shunt of lamb 6. Notice the change in height and downslope. The blue curves represent the change in ultrasound velocity recorded by the venous sensor. Example of a dilution curve during left-to-right shunt (c): the continuous line shows the derived curve, the interrupted line shows the primary curve after extrapolation and elimination of the indicator recirculation. British Journal of Anaesthesia 2012 108, 409-416DOI: (10.1093/bja/aer401) Copyright © 2012 The Author(s) Terms and Conditions