Paul Chapple Manager Technical & Sales Support

Slides:



Advertisements
Similar presentations
Challenger XL Be the Benchmark. Challenger XL Engineered Stronger, Faster, Better.
Advertisements

HVAC523 Heat Sources.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Refrigerators.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
 25,000 BTU per Cell  Cell Halves Edge Seams Folded and Crimped. Individual Cells Welded Together to Form Completed Heat Exchanger Assembly.  20 Gauge.
Heating Control Devices
HIGH EFFICIENCY WATER HEATERS - Residential Gas - Polaris ®
Millivolt Troubleshooting Guide Gas Products NOVA SIT Valves 1) Thermocouple Millivolt Check 2) Safety Magnet Testing 3) Thermopile Millivolt Check 4)
Engineered Products Make-Up Air for Heating and Cooling.
History of Vacuum Research Corp. Vacuum Research Corporation (VRC) traces its history back almost 60 years. VRC was one of the pioneer companies in the.
HVAC121 – Gas Heat Flame Rectification.
Gas Furnace Controls Part 4.
Expand Your Horizons The New High Efficiency Broiler Winner of the prestigious 2008 KI Award.
The 30M2 Continuous Miner. Customer Name 30M2 Overview %Heavy duty high power miner for mid-height seams %High productivity from efficient cutting and.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Product Introduction.
Gas Furnace Controls Part 2.
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
Blodgett Cafe Series July Cafe Series Spec Sheets 24” Range 36” Range 48” Range 60” Range 72” Range Radiant STK Infrared STK Banquet Broiler Cheesemelter.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
…an innovative shell and tube heat exchanger with an exceptionally high heat transfer coefficient for industrial fluid cooling and air conditioning.
E2 Motors and Motor Starting
Gas Furnace Planned Maintenance
7.4.1 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Operating Characteristics of Circuit Control Devices, Electromagnetic.
P5 – Electric Circuits. Static Electricity When two objects are rubbed together and become charged, electrons are transferred from one object to the other.
HYDRONIC HEATING AQUASTATS
Gasoline fuel supply systems Function: store, transport, Pressurize and filter gasoline going to carburetor or fuel injection system.
Robertshaw Millivolt Troubleshooting Guide Gas Products
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Why Maintenance Tasks are Important Produced by Joe Marchese.
1 HVAC122 - Gas Gas Valves. 2 Solenoid Gas Valves The solenoid gas valve is the simplest of all valves. This valve has an electrical magnetic coil which.
Update: Puck and Gun Magnet March 1, Magnetized Gun 2 K 2 CsSb Preparation Chamber HV Chamber.
Kaeser Direct Drive ESD Rotary Screw Compressor
Sigma Rotary Screw Compressors
P11008 ArcWorks Straw Cutting Device May 13, 2011 Ian Balbresky-ME/Pneumatics Lead Tyler Banta-ME/Design Lead Matthew Estock-ISE/Project Manager Mark Vaughn-ME/Fabrication.
E3 HVACR Controls and Devices
Understanding the system.
New Air Handler Platform
Unit 13 Oil-Burning Equipment
Unit 7 Gas Heat: Natural and LP
Teknologi Dan Rekayasa
Introducing the Bradford White ICON System™ and Accessory Packages
Natural Gas Production Chapter 4 Hydrate Formation
E3 HVACR Controls and Devices
Top Quality Pulse Jet Valve Manufactured by Maniks
Air Distribution Control
Pilot Operated Pulse Valve Manufactured by maniks
Chapter 8 – Cutting Processes
High Efficient Pulse Jet Valve Manufactured by maniks
Water Heater Repair – What to Do When You Get No Hot Water?
GMAW Welding Basic information.
Fuel Supply System Service
Wiring the Light and Relay
S8910U1000 Universal Electronic Ignition Modules Training Module
Solstice All Options Gas Fired Fryer Service Presentation (CE-UK)
VR8345 Universal Electronic Ignition Gas Valve Training Module
The perfect fit for corrosive wet areas Maintenance Units, Series MH1
Fluid Components for Small, Smart, Sampling Systems
FIGURE 35-1 If the vacuum hose is removed from the fuel-pressure regulator when the engine is running, the fuel pressure should increase. If it does not.
Solstice - Filtration System
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

Paul Chapple Manager Technical & Sales Support E: paulc@middlebyuk.co.uk T: 01925 821280, ext. 201 M: 07887 825922

Solstice Gas Fired Fryer Performance, Efficiency, Easy to Own

Pitco History 1918 Founded by John C. Pitman in Boston, MA 1950 moved from Massachusetts to New Hampshire 1981 Blodgett Corp purchases J.C. Pitman and named it Pitco Frialator Pitco manufacturers more than 135 models of both gas and electric frying equipment

What hasn’t changed Heat Transfer Area Pitco has up to 30% more heat transfer area compared to Brand 'X' By heating the oil from the bottom up, Brand 'X' has a smaller, less dispersed heat transfer area

The Cool Zone Pitco's cool zone is larger. The tube fired design creates a substantially larger cool zone for trapping particles thus prolonging oil life and reducing taste transfer Brand 'X' bottom-fired fryers have a cool zone limited in size by the shape of the tank design and the burner placement

Smart Simple Design Solstice Model SG14 3-burner 35C (4 burner 45C shown) Solstice Model SG14 Smart Simple Design

35C Economy Fryer 3 tubes – Nat gas or LP Cast iron burners (Heritage style) Stainless steel tank as standard, with 5 year parts warranty Manufactured to highest standard Easy to supply – only a ¾” gas line req’d, no electrics

35C Control Components Robertshaw Unitrol Mv Gas Valve Robertshaw GS Thermostat Robertshaw Hi-Limit Thermocouple Note: The GS thermostat is relatively trouble free but will run away if the gas tubing leaks. We are consolidating part numbers may be different. (high limits, relays)

35C Burners

Smart Simple Design Solstice Model SG14 3-burner 35C (4 burner 45C shown) Solstice Model SG14 Smart Simple Design

Robotic Welding Consistent and uniform welding process Unsurpassed accuracy World Class Quality (some competitors manufacture a new tank for EVERY fryer they manufacture!) Solstice tanks, in accelerated conditions, have never been replaced

Pressure Blasted Tanks Pitco tanks aren’t ground, they’re pressure blasted for a smoother surface and easier cleaning High tolerances at pressure points No welding scorch marks All tanks are pressure tested 3 times during manufacture to ensure 100% reliability Hand-finishing Pressure blasting Finished Tank

Solstice Gas Fryers Fry tanks are completely pressure blasted to clean and relieve stress at weld points, while smoothing surfaces for easier cleaning Special heating tubes feature high temperature, alloy stainless steel baffles for long life. Extremely large cool zone minimizes costly oil breakdowns, carbonization, and taste transfer Tube fired fryers require no extra insulation on the outside of the tank, making the fryer easier to service and eliminating the chance of capturing grease Pitco's 1 1/4" full port (I.D.) drains quickly and without clogging

Solstice Fryer Benefits Improved Efficiency Common Cabinet Design Stainless steel side panels Universal Control Harness Smart Layout More User Friendly

Solid Cabinet Design New, stainless cabinet sides ~ standard Easy to clean, rust resistant, preferred appearance Common front to back dimensions and drain height Easy to spec, mix & match any SG fryer in any configuration with or without integrated or portable filtration Asked for by consultants and customers Robust boxed-steel reinforced design Long life in tough restaurant environment Heavy-duty, double-skinned wide swing door Easy access, long lasting, insulated to reduce surface temp

New Solstice Burner Exclusive baffle design now squeezes out more heat More primary air is drawn in Exclusive baffle design now squeezes out more heat Flame has a longer path Baffle gets "radiant" faster

Exclusive Solstice Burner New, efficient inverted burner design Air is drawn high inside the cabinet Since hot air rises, inlet air is pre-heated Dust is less likely to be drawn into the burner Unique air flow cools front panel area Creates open space in cabinet for easy cleaning and service access

Burner

Baffled? How can you squeeze out more heat? Here’s how: Inside the heat tubes is a new stainless steel baffle design that slows down the flame so tubes heat evenly and efficiently transfer more heat to the oil Since more heat is squeezed out of the flame, flue temperature is reduced Old fryers 1100 to 1200 F° New fryers 800 to 900 F°

The Baffle

Behind the Computer

When you open the door

Ease of Service Front panel mounted controls Easy Access Individual fryer shut off valves Service one unit while adjacent fryer continues to work Large fitting reduces chance of clogging Dual "union" gas valve connectors Speed and ease of component replacement Common wire harness

Shut off Valves

Gas Valve Connectors

Quality Enhancements Exclusive new burner design Better in-stock service Enhanced tank design Sculptured sides for added strength Extensive field testing

Pitco Gas Fryer Options Mild steel tank (No longer available in UK) Stainless tank (Standard on all fryers in UK) All stainless steel (Front/door & sides are always stainless)??? SS back panel optional Gas manifold --- Rear Drain valve interlock switch (Not on MI/volt fryers) Back up Thermostat (Computer option only)

SG Safety Controls (CE Millivolt) High limit Thermocouple Pilot Coil

Safety Control Explanation Overview Pilot heats the Thermocouple generating DC voltage (25 - 35mVolt) DC Current flows through the High Limit to: Pilot Coil The energized coil generates magnetism. The magnetism holds the pilot valve open, allowing gas to flow to the main valve.

SG Operating Controls (CE Millivolt) Thermostat Thermopile Main Coil

Operating Control Explanation Overview Pilot heats the Thermopile generating DC voltage (400 - 600mVolt open circuit) DC Current flows through the Thermostat to Main Coil which energizes the main valve. TH,TP TH TP

Wiring Diagram (Door) Hi Limit , Thermocouple, “Radex” Wire Ass’y -- same as existing Thermopile, Thermostat, Gas valve -- new parts. Gas valve -- similar to CE Heritage standing pilot but has Millivolt actuator in place of 24VAC.

Control Adjustments & Checks Thermocouple Pilot should be adjusted to give 25-35mvolt Adjustment Check supply gas pressure is between 15 & 24mbar for Nat. Light pilot Attach volt meter across ground & a Hi-Limit connection Remove screw, adjust to 25 - 35mv & replace screw

Control Adjustments & Checks Pilot Assembly Gas Valve, Pressure Regulator

Control Adjustments & Checks Combination Gas Control Check out Turn on shut off valve Check incoming gas pressure is between 15 & 24mbar for Nat. Light pilot Check burner manifold pressure is 10mbar.

Smart Simple Filtration Design Easy to service Easy to operate Easy to clean