Unit 11 Wire Tables and Conductor Sizes. Objectives: Discuss factors that determine conductor ampacity. Discuss resistance of wire. Determine insulation.

Slides:



Advertisements
Similar presentations
Ch Electricity II. Electric Current (p ) Circuit Potential Difference Current Resistance Ohms Law.
Advertisements

Chapter 17 Direct currents
Chapter 20 Electricity.
1 INTRODUCTION TO ELECTRICAL THEORY 2 What is Electricity? The controlled flow of electrons in an electrical circuit. A circuit must always be a complete.
National Electrical Code Article 310
Chapter 3 Resistance.
Chapter 11 Inductors.
Basic Electronics Ninth Edition Basic Electronics Ninth Edition ©2002 The McGraw-Hill Companies Grob Schultz.
Phy 213: General Physics III Chapter 26: Electric Current Lecture Notes.
Chapter 17.2 – Current electrical potential energy –
12 TH STANDARD PHYSICS CURRENT ELECTRICITY Prepared by: R.RAJENDRAN, M.A., M.Sc., M.Ed., N.INGARAN, M.Sc., M.Phil.,M.Ed.,
Chapter 13 Transmission Lines
Chapter 17 Current and Resistance. Electric Current Let us look at the charges flowing perpendicularly to a surface of area A The electric current is.
Electrical Resistance Physics A Current #3  Targets:  I can explain resistance and its function in a circuit.  I can calculate resistance in series.
Benchmark Companies Inc PO Box Aurora CO Conductors, Insulators, Semiconductors.
DC electronics. Resistance Because electrons have mass and are held in place by polarity “bonds” – energy is consumed to dislodge electrons Resistance.
Conductors and Insulators
ELECTRONIC/COMPUTER AGE. Electronic/Computer Age  Electronics –Electrical signals can carry information quickly over wires or through the air by radio.
EET Electronics Survey Chapter 9 - Circuit Conductors & Wire Sizes.
Lesson 3 Measuring and Calculating Electricity. Next Generation Science/Common Core Standards Addressed! §CCSS.ELA Literacy.RST.9 ‐ 10.3Follow precisely.
Chapter 3 Resistance ECET 1010 Fundamentals.
Chapter 3 Resistance.
Hazard - Inadequate Wiring
Resistance. This is a measure of a materials opposition to the flow of current through it. Unit: Ohms ( Ω )
Resistance and Ohm’s Law Alessandro VoltaAndre Ampere Georg Ohm.
Introduction to Basic Electrical Circuit Materials
Electric Current. Answer Me!!!  Why are electric wires made from metal?
Lecture 12 Current & Resistance (2)
Electronic Concepts Hussam Al-Hertani Principles of Electricity.
Current, Resistance and Power
Electrical Resistance and Ohm’s Law Electric circuits are used to convert electrical energy into some other form of energy we need.
ECE 476 Power System Analysis Lecture 7: Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
1 Hong Kong Institute of Vocational Education Electrical & Telecommunications Course Board Lecture Notes.
EXAMPLE 27.1: A copper wire carries a current of 10 A. It has a cross- sectional area of 0.05 cm 2. Estimate the drift velocity of the electrons.
PROPORTION Given that y is proportional to x, find the missing values of y x y18.
Basic Electrical Circuit Materials Colts Neck High School Applied Technology.
Moving Electricity – Electrical Circuits and Current.
Lesson Measuring and Calculating Electricity. Interest Approach § Have you or your parents ever been using several appliances in the kitchen and had a.
Electric Current and Ohm’s Law. Electric Current Electric current is the continuous flow of electric charge Two types of current are direct and alternating.
Ch Electricity II. Electric Current  Cell and Battery  Potential Difference  Current  Resistance  Ohm’s Law.
Conductors and Insulators
Chapter 7-2 Electric Current. Electric Pressure (Voltage) Charges flow from high-voltage areas to low-voltage areas Think about it like water: water flows.
PHY-2049 Chapter 27 Circuits. A closed circuit Hot, Hot Hot.
E E 1205 Circuit Analysis Lecture 03 - Simple Resistive Circuits and Applications.
 The property of a substance due to which it opposes (or restricts) the flow of electricity (i.e., electrons) through it.  The flow of charge through.
Installation of Heating, Cooling, and Refrigeration Systems Electricity for Refrigeration, Heating and Air Conditioning 7th Edition Chapter 8 Installation.
Regents Physics 11/10/2008 Mrs. Nephew. Electric Current The rate at which charge passes a given point in a circuit. Electric Circuit=a closed path along.
CH 5 – Electricity and Magnetism
Resistance.
RESISTANCE.
Ch Electricity II. Electric Current (p ) Circuit
Resistance in Circuits
NEC and Ampacity.
Electrical potential energy and resistance
Resistance and Conductance
Current electricity.
Electrical Stopping Power Electrical Resistance
Chapter 27 Problems 1,11,12,15,16,22,32,33,36,49,56.
EET 323 – Electrical System Design Lecture 6: Conductors and Over-Current Protection Radian Belu, PhD.
RESISTANCE.
Electricity II. Electric Current Circuit Potential Difference Current
Transformer Calculations: Word Problems
Resistance.
Resistance.
Aim: How do we explain resistance?
Smitty’s Two Minute Drill General Knowledge 2
Calculations Review Drill
Presentation transcript:

Unit 11 Wire Tables and Conductor Sizes

Objectives: Discuss factors that determine conductor ampacity. Discuss resistance of wire. Determine insulation characteristics. Use temperature correction factors. Determine conductor resistance.

Unit 11 Wire Tables and Conductor Sizes Objectives: Determine proper wire sizes. List parallel conductor requirements. Discuss testing insulation with a MEGGER ®

Unit 11 Wire Tables and Conductor Sizes NEC ® Tables and Charts Chapter 3 of the NEC ® provides general information about Wiring Methods and Materials. Tables through are the most often referenced tables in the Code. These tables provide critical information about conductor ampacity (current-carrying ability).

Unit 11 Wire Tables and Conductor Sizes Factors That Determine Ampacity Conductor Material Copper Aluminum Copper-clad aluminum Insulation Type Table Insulation information 60°C, 75°C, or 90°C columns

Unit 11 Wire Tables and Conductor Sizes Factors That Determine Ampacity Correction Factors are used to adjust ampacity based on ambient air temperature. High ambient air temperatures reduce conductor ampacity. Low ambient air temperatures increase conductor ampacity.

Unit 11 Wire Tables and Conductor Sizes Factors That Determine Ampacity Temperature correction factors are found at the bottom of the tables. When more than three current-carrying conductors are installed in the same raceway, their respective ampacities must be reduced. NEC ® Table (B)(2)(a) provides the percentages used to adjust ampacity.

Unit 11 Wire Tables and Conductor Sizes Resistance of Wire Four factors determine the resistance of a length of wire: 1. The type of wire material. 2. The cross sectional area of a conductor as measured in circular mils (CM). 3. The length of the conductor. 4. The temperature of the conductor.

Unit 11 Wire Tables and Conductor Sizes Resistivity (K) of Materials As a general rule, the resistance of most conductive materials increases with rising temperature. Their resistance decreases with falling temperatures. These materials have a positive coefficient of temperature (K). Examples: Copper, Aluminum, Tungsten

Unit 11 Wire Tables and Conductor Sizes Resistivity (K) of Materials A few conductive materials have decreasing resistivity with rising temperature and their resistance increases with falling temperatures. These materials have a negative coefficient of temperature (K). Examples: Carbon, Silicon, Germanium.

Unit 11 Wire Tables and Conductor Sizes.

Circular Mil (CM) A mil is one thousandth of an inch (0.001). A circular mil is a circle with a diameter of one mil.

Unit 11 Wire Tables and Conductor Sizes Circular Mil (CM) Area The diameter of a wire is converted to mils. This number in mils is squared. CM = d 2

Unit 11 Wire Tables and Conductor Sizes Mil Foot A wire 1 foot long and 1 mil in diameter.

Unit 11 Wire Tables and Conductor Sizes Computing Resistance R = (K x L) / CM R = resistance of the wire K = ohms per mil foot (Copper = 10.4) L = length of wire in feet CM = circular mil area of wire.

Unit 11 Wire Tables and Conductor Sizes Computing Voltage Drop E = I x R (Ohms Law) E (volt drop) = I x R (wire) I = current.

Unit 11 Wire Tables and Conductor Sizes Computing Single-Phase Voltage Drop E D = (2 x K x I x L) / CM E D = voltage drop K = ohms per mil foot I = current L = length of conductor in feet CM = circular mil area of the conductor Also known as the Two Kil Formula..

Unit 11 Wire Tables and Conductor Sizes Computing Three-Phase Voltage Drop E D = (3 x K x I x L) / CM E D = voltage drop K = ohms per mil foot I = current L = length of conductor in feet CM = circular mil area of the conductor.

Unit 11 Wire Tables and Conductor Sizes Parallel Conductor Rules Identical length of conductors. Identical conductor material. Identical conductor circular mil area. Identical conductor insulation type. Identical terminations of conductors. Each raceway contains all phase legs..

Unit 11 Wire Tables and Conductor Sizes Parallel Conductors.

Unit 11 Wire Tables and Conductor Sizes Installations are often checked with a MEGGER ® before a system is energized. In order to test the quality of the insulation, a very high voltage but low current is impressed on the system. Thus wiring defects can be determined and corrected safely.

Unit 11 Wire Tables and Conductor Sizes Testing for shorts with a MEGGER ®.

Unit 11 Wire Tables and Conductor Sizes Testing for grounds with a MEGGER ®.

Unit 11 Wire Tables and Conductor Sizes Review: 1.The NEC ® tables are used for wire sizing. 2.Four factors determine wire resistance: a.the type of conductor material. b.the conductor length. c.the conductor circular mil area. d.the conductor temperature.

Unit 11 Wire Tables and Conductor Sizes Review: 3.Conductor ampacity must be reduced in high-temperature locations. 4.More than three conductors in a raceway requires ampacity reduction. 5.Conductor ampacity is affected by the type of wire insulation.

Unit 11 Wire Tables and Conductor Sizes Review: 6.The English system uses the mil foot as a standard reference. 7.Conductors should be checked with a MEGGER® after installation.