Central Control Unit (Com - ports) LBB3500/15

Slides:



Advertisements
Similar presentations
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO ASM Application Software Modules.
Advertisements

Interpreter Desk LBB 3520/10 1. Loudspeaker Volume control (floor)
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO AIE Trunk Extension Cables LBB4116/xx Cable without connectors LBB 4116/
Security Systems BU Communication Systems ST/SEU-CO 1 DCN MCCU SD Hardware Multi- Central Control Units MCCU System Hardware Basic PC Multi-
EPOS Studio Configuration
Test on Input, Output, Processing, & Storage Devices
Dual Audio Interface Unit LBB 3535/00
Power handling and control capacity
DE2-115 Control Panel - Part I
DCN Remote control facilities
Central Control Equipment
Security Systems BU Communication Systems Slide 1 DCNtech MPCC IO NClientPC Installing and Operating with Multi PC Control  Windows Set-up.
DCN Next Generation Open Interface
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 ApplicationNote MCCU How to install a Multi-CCU system.
QUICK GUIDE MANUAL GV-DVR System Organization 2. Specification.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 PC Controlled Cam. Control How to configure PC Controlled Camera Control.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN MPCC IO ASM ClientPC Installing the Application Software Modules on the Client.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
System set up procedure equalizing a system
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA SD Mix-M Mode Mix-Minus Mode  Prevent echo due to this feedback.  Audio-signals,
Nokia 30 technical specification
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 Stand Alone Camera Control How to configure Stand Alone Camera Control.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
CCS 800 Ultro - the discussion system with digital acoustic
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
KX-NS1000 Initial Set Up For step by step : 16 May,
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO TTU Standard Table Top Discussion Units IFU Manual.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
DP Cabinet.
Preparing … First of all, recycle monitor power using AC power switch. Connect serial cable between your PC and monitor. (RS-232 Connector). Refer to Appendix.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC IO ASM Installing all Application Software Modules.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA SD Technology The DCN Technology  Full Digital Audio and Data transport and processing.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN MCCU SD Technology Multi- CCU Channel Handling Discussion / Conference systems  Max.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA SD Insertion Mode Audio routing in Insertion Mode  Open audio path between the.
SXBlue II GPS CHAPTER – I ABOUT HARDWARE AND SOFTWARE.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN MPCC PO MPC Multi PC’s  High Performance PC’s  Microsoft Windows® NT 4.0, 2000.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Business Enabled Communications
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA IO Installing Installing a System I&O Manual.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
The Vision of a Leader Rapid Eye Plus Technical Training.
ADAM Single Writer User’s Manual ETA Chips Co., Kr, 2011 Rev 1.0.
COE4OI5 Engineering Design Chapter 2: UP2/UP3 board.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
INTER REGIONAL PROCESSOR. DESIGN PHILOSOPHY n Based on industry standard pc hardware. n Industrial specification IBM compatible computer running Fylde.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
TECHNICAL TRAINING 2007 CONTROLLER PROGRAM UPGRADE.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC SD Technology ACN - Protocol  Maximum Capacity of Translation Channels Audio.
Digital Message Announcer DMA-1. Solid State Digital Audio Player Applications: security warning messages security warning messages voice alarms voice.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Single CCU System with Control PC and DIRECT Connection
Addressing a Multi CCU System
Microcomputer Systems 1
Central Control Unit (Com - ports) LBB3500/15
How to configure Stand Alone Camera Control
Multi Central Control Unit LBB 3500/35
Presentation transcript:

Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector RS 232 for: Facilities factory testing (diagnostics) direct PC control camera control remote control (Open interface) applications for: - Mimic panel (Microphone control) - Voting panel - Attendance registration - Intercom - Message Distribution I&O Manual 08.12.2004 DCN SPCC PO CCE

Central Control Unit (Com - ports) LBB3500/15 Open interface applications for remote controller The DCN system provides a facility for controlling microphones, microphone management modes, attendance registration and voting from a remote controller. The remote controller can be custom built for a given application to control microphone activity - for example a push- button panel, with on/ off push-buttons and indicator. LEDs assigned to each microphone position can be used to control delegates microphones from a remote position. The communication protocol is message based binary interface (i. e remote functions and update information). Note: Before third parties can use the remote interface, the interface must be enabled on the CCU by installing the LBB3587 key-disk. - Only possible by using the LBB 3500/15 or /35 08.12.2004 DCN SPCC PO CCE

CCU Trunk Communication Board (TCB-4) Key to symbols : 1 Jumper X14 (See Chapter 4.5.3 (Table 4.4)) 2 S14 DIP- switches 1 - 8 (See Chapter 4.6 ) 3 S10 Push- button switch to reset the Central Control Unit during servicing. 4 Three LEDs (left to right) green/ yellow/ red. Normally the green/ yellow LEDs flash in sequence, indicating the software is running. Red LED illuminates during system reset. 5 S9 DIP- switches 1 - 8 (See Chapter 4.5.2 (Table 4.3)) 6 Yellow LED indicates Digital Signal Processing (DSP) software is running. 7 Connector for multi- trunk board (used only in the multi- CCU) 8 Sockets for inserting flash EPROM (even) 9 Sockets for inserting flash EPROM (odd) 08.12.2004 DCN SPCC PO CCE

CCU Trunk Communication Board (TCB-4) Key to symbols : 10 SRAM back- up battery 3.6 V (life- time 5 years min.) 11 Jumper X13 (See Chapter 4.5.3 (Tables 4.4)) 12 Fuse 3.15 amp (delayed) 13 Connector for multi- trunk board (used only in the multi- CCU) 14 Serial RS232 Port 1 15 Serial RS232 Port 2 08.12.2004 DCN SPCC PO CCE

Central Control Unit (Com - ports) LBB3500/15 LBB 3500/ 15 and LBB 3500/ 35 (TCB 4) Port 1 : DCN Control PC Port 2 : Camera Control In a single (stand- alone) CCU system two serial COM- ports (Port 1 and Port 2) are available. Both ports can be individually configured. NOTE: It is possible to select ‘Full’ protocol on both Port 1 and Port 2. However this is NOT recommended due to processing power and memory limitations. Default settings are; 8 data bits No parity check 1 Stop bit 08.12.2004 DCN SPCC PO CCE

TCB-4 DIP Switch Settings (default) 08.12.2004 DCN SPCC PO CCE

Central Control Unit (Audio I/O) LBB3500/15 2 1. Asymmetrical Recorder In- & Outputs 2. 2 Asymmetrical line input connectors 3. Symmetrical or 2 Asymmetrical line outputs 08.12.2004 DCN SPCC PO CCE

Central Control Unit (Audio I/O) LBB3500/15 1. Tape/cassette recorder input and output (Cinch-type) Tape In Asym. nom. -33 dBV max. -3 dBV Tape Out Asym. nom. -33 dBV max. -3 dBV 2. 2 Asymmetrical line input connectors (Cinch-type) Line In Asym. nom. -18 dBV max. +12 dBV 3. Symmetrical/Asymmetrical line output connectors (Cinch-type) Line Out Sym. nom. -12 dBV max. +18 dBV Line Out Asym nom. -18 dBV max. +12 dBV 08.12.2004 DCN SPCC PO CCE

Central Control Unit (Trunk Outlets) LBB3500/15 1. Red LED overload indicators 2. Trunk outlet used for loop-through of the trunk-line-cable 1 2 Trunk 08.12.2004 DCN SPCC PO CCE

Central Control Unit (Trunk Outlets) LBB3500/15 For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet - 180 PCF total for the three outlets of the CCU. PCF=<60 max. 08.12.2004 DCN SPCC PO CCE

Extension Power Supply LBB4106/x0 1. Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 4A (slow blow) 350 W 105, 115 V, 125 V AC. T- 5A (slow blow) Warning: All units must be powered via an earthed mains outlet. 115V-T4A/230V-T2A I&O Manual 08.12.2004 DCN SPCC PO CCE

Central Control Equipment End of section  Robert Bosch GmbH All rights are reserved. Reproduction or passing on to third parties in whole or in parts is prohibited without the written consent of the copyright owner. 08.12.2004 DCN SPCC PO CCE