Brightness Control Systems

Slides:



Advertisements
Similar presentations
Line focus principle Heal effect Ratings Tube failure
Advertisements

Chapter 11 Prime Factors.
December 10, 2004by Debbie Miller1 Fuchs’s Radiographic Principles THE 15 PERCENT RULE.
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
MAMMO QC – covered in week 8
Analyzing the Image Density. Density Overall blackening of the image.
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
Radiographic Technique Evaluation
Fluoroscopy: Viewing Systems
The X-ray Imaging System
Fluoroscopy Equipment
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
DIGITAL FLUOROSCOPY.
Special Imaging Systems
CHAPTER 3 EQUIPMENT OPERATION AND QUALITY CONTROL
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Exposure Factors or Prime Factors
Preparing Variable kVp Technique Charts By Prof. Stelmark.
Appendix H: Chapter 40: Fluoroscopy
What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.
Radiographic Quality Visibility and Sharpness
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
TECHNIQUE CHARTS SERGEO GUILBAUD CLINICAL COORDINATOR.
Automatic Exposure Control (AEC)
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
Exposure Factors or Prime Factors
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
1 / Basic X Ray 2 / X-ray 简介 X 光球管简介 高压发生器简介 普通放射设备简介 透视摄影简介 血管造影设备简介 Topics.
THE X-RAY UNIT THE BASICS.
Resident Physics Lectures
Optimisation of Patient Protection for Radiography
Introduction to and History of Fluoroscopy Radiation Protection
Radiographic Contrast
THE X-RAY UNIT THE BASICS.
Factors Effecting the Production
Exposure Factors Chapter 4
Medical Imaging Imagining Modalities.
Characteristic Radiation in Tungsten Targets Shell # of electrons Binding energy L Char M N O P Eff X-ray Energy K
Fluoroscopic Unit Thomas Edison 1896.
Fluoroscopy: Dynamic Imaging Systems
Resident Physics Lectures
Pima Medical Institute Online Education
Pediatric Fluoroscopy
Fluoroscopy Dynamic Image Recording Systems
Fluoroscopic Brightness Control Systems
Fluoroscopic Image Intensifier Image production
Mobile Fluoroscopy Based on:
Mobile Fluoroscopy Based on:
Fluoroscopy Dynamic Image Recording Systems
Fluoroscopy: Viewing Systems
Introduction to and History of Fluoroscopy Radiation Protection
Pediatric Fluoroscopy
Fluoroscopy Static Image Recording Systems
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy – Viewing Systems Optical Mirrors TV Camera & TV Camera Tubes Charge Coupled Devices (CCD) Based on: Principles of Radiographic Imaging, 3rd.
Pediatric Fluoroscopy
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy Static Image Recording Systems
Pima Medical Institute Online Education
Fluoroscopic Image Quality Considerations
Digital Fluoroscopy PPT created by: Jed Miles, BSRS, RT(R), CRT-CA
Fluoroscopic Image Intensifier Image Production
Fluoroscopy: Static Image Recording Systems
Mobile Fluoroscopy.
Fluoroscopic Image Quality Considerations
Presentation transcript:

Brightness Control Systems

X-Ray Generators X-ray generators X-ray generators used for static radiography are also used for fluoroscopy X-ray generators Static Radiography Operator’s console has a control that will engage or activate the fluoroscopic system and bypass the static radiography system Fluoroscopy

Brightness Control Systems Wide variety of systems with different names are used to automatically maintain satisfactory fluoroscopic image density and contrast Automatic Brightness Control (ABC) Automatic Density Control (ADC) Automatic Brightness Stabilization (ABS) All terms relate to and accomplish the same result: Maintain brightness of viewable image Automatically adjust exposure factors as necessary according to subject density and contrast

Or monitors light intensity of output screen ABC Systems Monitor Monitor electrical (electron) current flow between cathode and anode of image intensification tube cathode Image Intensification Tube anode Or monitors light intensity of output screen Output Screen

ABC Systems Monitor In all systems, the “primary x-ray beam” intensity is increased or decreased when the intensified light output varies from established brightness levels Established Levels Current Intensity

Regulation of Primary Beam Regulation of primary beam is accomplished by varying: kVp mA Pulse time Most ABC’s will use a combination of these methods in a manner similar to stepped variable kVp systems: kVp is gradually increased to the maximum acceptable contrast level Then mA is doubled while kVp is stepped down to the lowest acceptable contrast level This process constantly repeated over and over

Response Time Lung Field Most ABC’s have a relatively slow response time (noticeable during routine fluoro) This is realized as a lag in the image brightness adjustment when rapid changes in tissue density are present Lung Field Example: Fluoro from lung field to abdomen

Automatic Gain Control (AGC) AGC is part of the video camera control system AGC will respond very quickly to change image brightness and density Does NOT change x-ray exposure factors!

Please close this PowerPoint presentation, and continue the lesson. What’s Next? Please close this PowerPoint presentation, and continue the lesson. Presented by Based on: Principles of Radiographic Imaging, 4th Ed. By: R. Carlton & A. Adler Radiologic Science for Technologists, 8th Ed. By: S. Bushong Syllabus on Fluoroscopy Radiation Protection, 6th Rev. By: Radiologic Health Branch – Certification Unit