X-ray detectors single photon detectors

Slides:



Advertisements
Similar presentations
GM COUNTER.
Advertisements

FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Radiation Detectors / Particle Detectors
Semiconductor Light Detectors ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
Lesson 17 Detectors. Introduction When radiation interacts with matter, result is the production of energetic electrons. (Neutrons lead to secondary processes.
Photomultiplier Tube m = k 8–19 dynodes (9-10 is most common).
1 Detectors RIT Course Number Lecture Single Element Detectors.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Transducers Converts one type of energy into another. Light  Electrical (current, voltage, etc.) What characteristics should we look for in a transducer?
Introduction to X-Ray Fluorescence NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade – Faculty of Chemistry.
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Main detector types Scintillation Detector Spectrum.
Radiation Detection and Measurement II IRAD 2731.
X RAY SPECTROSCOPY.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Atomic Absorption Terry A. Ring Chemical Engineering University of Utah.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Slide # 1 Examples of pressure sensor packaging Temperature characteristics of a piezoresistive pressure sensor. Transfer function at three different temperatures.
Properties of X-Rays Reference: “Elements of X-ray Diffraction”, 3nd Edition, B.D. Cullity, and S.R. Stock, Prentice Hall, NJ Chapter 1
Components of Optical Instruments, Cont… Lecture 8.
Photon detection Visible or near-visible wavelengths
CLRS 321 Nuclear Medicine Physics & Instrumentation I Part C: Semiconductors and Miscellaneous Scintillation Devices Unit II: Nuclear Medicine Measuring.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Chapter 12 Atomic X-Ray Spectroscopy
1 Components of Optical Instruments Lecture Silicon Diode Transducers A semiconductor material like silicon can be doped by an element of group.
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Detectors (UV-Vis) 1. Phototube 2. Photomultiplier Tube (PMT) 3. Si Photodiode 4. Photodiode Array (PDA) 5. Charge Coupled Device (CCD) 6. Charge Injection.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Ionization Detectors Basic operation
DØ Central Tracker Replaced with New Scintillating Fiber Tracker and Silicon Vertex Detector The DØ Central Detector Upgrade The DØ Detector is a 5000.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Ideal Detector Fast Cheap Rugged Responds to all wavelengths of light Can distinguish different wavelengths Sensitive Low LOD.
Chapter V Radiation Detectors.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Muhammad Musaddiq.
3/2003 Rev 1 II.3.5 – slide 1 of 23 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Session II.3.5 Part IIQuantities.
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
(Chapter 7) CHEM–E5225 Electron microscopy
Elettra Sincrotrone Trieste
Chem. 133 – 3/30 Lecture.
OPTICAL SOURCE : Light Emitting Diodes (LEDs)
Chapter 3. Components of Optical Instruments
PAN-2013: Radiation detectors
Instrument Parameters in WDXRF
CLRS 321 Nuclear Medicine Physics & Instrumentation I
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Chem. 133 – 2/9 Lecture.
Elemental composition
BMS 602/631 - LECTURE 7 Flow Cytometry: Theory
Neutron Detectors for Materials Research
Scintillation Counter
When this happens... We see this... 12/6/2018 Steve Wotton.
Lecture 1—Basic Principles of Scintillation
Oct 10, 2018 Muhammad Qasim Abdul Wali Khan University, Department of Physics, Mardan, Pakistan by.
Radiation Sensors Radiation is emission if either particles or electromagnetic rays from a source. Particles are usually nuclear particles which can be.
ECE699 – 004 Sensor Device Technology
Semiconductor Detectors
Radioactivity B. Sc. -III Feb Dr. Wagh G. S. M. Sc. M. Phil. Ph
Recall-Lecture 6 Diode AC equivalent circuit – small signal analysis
Photomultiplier (PMT) Tubes
PARTICLE DETECTORS I recently joined the IAEA.
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Radhabai Kale Mahila Mahavidhyalaya, Ppt. name:- x-Ray techniques
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
Computed Tomography (C.T)
Presentation transcript:

X-ray detectors single photon detectors scintillation detectors (gas-filled) proportional counters semiconductor detectors linear (position-sensitive) detectors gas-filled (wire) detectors charge-coupled devices (CCD’s) area detectors 2-D wire detectors CCD area detectors X-ray film

Gas-filled proportional counter A proportional counter consists of the following main components: a gas-filled cylindrical envelope (usually Ar, Kr, or Xe) a central anode wire a grounded coaxial cylinder (the cathode) an X-ray transparent window Cullity (cathode at high voltage?) Klug & Alexander (grounded cathode)

Gas-filled proportional counter When an X-ray photon ionizes a gas molecule, the ejected photoelectrons are accelerated to the anode low voltages – photoelectrons don’t have enough energy to ionize other molecules intermediate voltages – gas amplification occurs (photo-electrons ionize gas molecules on the way to the anode high voltages – discharge occurs throughout the gas volume

The scintillation detector most common detector in materials analysis by X-ray diffraction the detector has two basic elements: a crystal that fluoresces visible light (scintillates) when struck by X-ray photons a photomultiplier tube (PMT) that converts the light to electrical pulses gain ~5 per dynode (total gain with ten dynodes is 510  107) NaI(Tl) scintillator (very sensitive to moisture) – emits around 4200Å CsSb photocathode – ejects electrons

Semiconductor detectors Semiconductor detectors are solid-state proportional counters – each photon produces electron-hole (e/h) pairs The detection of e/h pairs would not be possible if the semiconductor has free carriers (n-type or p-type) so it must be intrinsic – this can be done by “lithium drifting” p n p n apply V p--Si heat Li+ i lithium lightly p-doped Si has Li plated heat to have the Li diffuse apply a reverse bias to cause Li+ ions to “drift a wide central intrinsic region is formed

Random aspects of semiconductor detectors originally: Si(Li) and Ge(Li) – “silly” and “jelly” now intrinsic Si and intrinsic Ge are available (Ge better due to higher absorption and better energy resolution) energy resolution about 2% small signal requires a charge-sensitive preamp integrated with the detector due to thermal e/h generation and noise in the preamp, cooling to 77K is needed new detectors use Si p-i-n photodiodes and large bandgap materials (CdTe and CdZnTe) for room-temperature operation

Random aspects of semiconductor detectors originally: Si(Li) and Ge(Li) – “silly” and “jelly” now intrinsic Si and intrinsic Ge are available (Ge better due to higher absorption and better energy resolution) energy resolution about 2% small signal requires a charge-sensitive preamp integrated with the detector due to thermal e/h generation and noise in the preamp, cooling to 77K is needed new detectors use Si p-i-n photodiodes and large bandgap materials (CdTe and CdZnTe) for room-temperature operation

Diffractometer operation The steps taken in diffractometer operation depends on whether the system is being used for powder analyses or single crystal analyses

Neutrons and electron diffraction Louis de Broglie: h=6.62606896×10−34 J.s

X-ray Fluorescence Spectrometry (XRF)

Energy dispersive spectrometry schematic arrangement of EDX spectrometer

Wavelength dispersive spectrometry (WDS)

Crystals The desirable characteristics of a diffraction crystal are: High diffraction intensity High dispersion Narrow diffracted peak width High peak-to-background Absence of interfering elements Low thermal coefficient of expansion Stability in air and on exposure to X-rays Ready availability Low cost

Normally, the maximum achievable θ angle in a WDS system is about 73◦ Normally, the maximum achievable θ angle in a WDS system is about 73◦. Thus, the maximum λ of characteristic X-rays being diffracted is about 1.9d of the analyzing crystal.

Crystals with simple structure tend to give the best diffraction performance. Crystals containing heavy atoms can diffract well, but also fluoresce themselves, causing interference. Crystals that are water-soluble, volatile or organic tend to give poor stability. Commonly used crystal materials include LiF (lithium fluoride), ADP (ammonium dihydrogen phosphate), Ge (germanium), graphite, InSb (indium antimonide), PE (tetrakis-(hydroxymethyl)-methane: penta-erythritol), KAP (potassium hydrogen phthalate), RbAP (rubidium hydrogen phthalate) and TlAP (thallium(I) hydrogen phthalate). In addition, there is an increasing use of "layered synthetic microstructures", which are "sandwich" structured materials comprising successive thick layers of low atomic number matrix, and monatomic layers of a heavy element. These can in principle be custom-manufactured to diffract any desired long wavelength, and are used extensively for elements in the range Li to Mg.