Tear size and location impacts false lumen pressure in an ex vivo model of chronic type B aortic dissection  Thomas T. Tsai, MD, Marty S. Schlicht, MS,

Slides:



Advertisements
Similar presentations
Professionalism and the work-life balance Thomas S. Huber, MD, PhD Journal of Vascular Surgery Volume 60, Issue 4, Pages (October 2014) DOI:
Advertisements

Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection 
Mark J.W. Koelemay, MD, PhD  Journal of Vascular Surgery 
Predictors of aortic growth in uncomplicated type B aortic dissection
Mohammed Al-Omran, MD, MSc  Journal of Vascular Surgery 
Acute bilateral renal artery chimney stent thrombosis after endovascular repair of a juxtarenal abdominal aortic aneurysm  Salvatore T. Scali, MD, Robert.
Results of a multicenter, prospective trial of thoracic endovascular aortic repair for blunt thoracic aortic injury (RESCUE trial)  Ali Khoynezhad, MD,
Gregory A. Stanley, MD, Erin H
Stephen P. Wiet, MD, William H. Pearce, MD, Walter J
Vocal cord paralysis after aortic arch surgery: Predictors and clinical outcome  Noriyuki Ohta, MD, PhD, Toru Kuratani, MD, PhD, Satoshi Hagihira, MD,
Aortoduodenal fistula 5 years after endovascular abdominal aortic aneurysm repair with the Ancure stent graft  Blaine J. Ruby, MD, Thomas H. Cogbill,
Peyman Benharash, MD, Jason T. Lee, MD, Oscar J
Endovascular repair of Stanford B aortic dissection using two stent grafts with different sizes  Xiaoyong Huang, MD, Lianjun Huang, MD, Lizhong Sun, MD,
Antegrade Thoracic Stent Grafting During Repair of Acute DeBakey I Dissection Prevents Development of Thoracoabdominal Aortic Aneurysms  Alberto Pochettino,
Olivier H. J. Koning, MD, Jan-Willem Hinnen, MD, Jary M
Toronto PowerWire fenestration technique to access false lumen branches in fenestrated endovascular aneurysm repair for chronic type B dissection  Steffan.
Douglas M. Cavaye, FRACS, William J. French, MD, Rodney A
Distal True Lumen Compression After Thoracic Endovascular Repair for Aortic Dissection Treated With Endovascular Fenestration  David J. O'Connor, MD,
Staged hybrid approach for an acute-on-chronic aortic dissection with rupture in a Jehovah's Witness patient: Case report  Sarah T. Ward, MD, Minhaj S.
The “Lantern” Procedure to Simplify Treatment of Retrograde Type A Dissection After Thoracic Endograft Stenting  Chung-Lin Tsai, MD  The Annals of Thoracic.
Open bypass and endovascular procedures among diabetic foot ulcer cases in the United States from 2001 to 2010  Grant H. Skrepnek, PhD, David G. Armstrong,
Journal of Vascular Surgery
A multicenter experience evaluating chronic total occlusion crossing with the Wildcat catheter (the CONNECT study)  John P. Pigott, MD, FACS, M. Laiq.
Endovascular stent graft for symptomatic mobile thrombus of the thoracic aorta  Philipp Fueglistaler, MD, Thomas Wolff, MD, Lorenz Guerke, MD, Peter Stierli,
Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone.
Determination of the elastic modulus of ascending thoracic aortic aneurysm at different ranges of pressure using uniaxial tensile testing  Khalil Khanafer,
Christopher L. Stout, MD, Eric C. Scott, MD, Gordon K
Mark F. Conrad, MD, Robert S. Crawford, MD, Christopher J
Efficacy of thoracic endovascular stent repair for chronic type B aortic dissection with aneurysmal degeneration  Salvatore T. Scali, MD, Robert J. Feezor,
Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection  Yong-Lin Qin, MD, Gang.
Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection 
Successful surgical treatment of multilevel aortic aneurysms combined with renal transplantation  Ivan Matia, MD, PhD, Jan Pirk, MD, PhD, Květoslav Lipar,
Ali Khoynezhad, MD, Irwin Walot, MD, Matthew J
Acute abdominal aortic dissection: Insight from the International Registry of Acute Aortic Dissection (IRAD)  Santi Trimarchi, MD, Thomas Tsai, MD, Kim.
Human ex-vivo model of Stanford type B aortic dissection
Late complications of thoracic endografts
Enlargement of aortic arch vessels after surgical repair of type A aortic dissection  Takashi Yamauchi, MD, PhD, Suguru Kubota, MD, PhD, Toshihiro Ohata,
Successful treatment of disseminated intravascular coagulation associated with aortic dissection  Masahiko Fujii, MD, Hiroyuki Watanabe, MD, Masayoshi.
Endograft Exclusion of the False Lumen Restores Local Hemodynamics in a Model of Type B Aortic Dissection  Joav Birjiniuk, John Oshinski, David Ku, Ravi.
Pediatric venous thromboembolism in relation to adults
Use of computational fluid dynamics studies in predicting aneurysmal degeneration of acute type B aortic dissections  Eric K. Shang, MD, Derek P. Nathan,
Acute iatrogenic type A aortic dissection following thoracic aortic endografting  Gabriele Piffaretti, MD, Giovanni Mariscalco, MD, PhD, Matteo Tozzi,
Placement of a branched stent graft into the false lumen of a chronic type B aortic dissection  Dominic Simring, FRACS (Vasc), Jowad Raja, MRCS, FRCR,
Successful treatment of disseminated intravascular coagulation associated with aortic dissection  Masahiko Fujii, MD, Hiroyuki Watanabe, MD, Masayoshi.
Staged hybrid repair of extensive thoracoabdominal aortic aneurysms secondary to chronic aortic dissection  Amit Jain, MD, Tanya F. Flohr, MD, William.
Sources of error in the measurement of aortic diameter in computed tomography scans  Juan Parodi, MD, Ramon Berguer, MD, PhD, Patricia Carrascosa, MD,
A morphologic study of chronic type B aortic dissections and aneurysms after thoracic endovascular stent grafting  Kai-xiong Qing, MBBS, MMed, Wai-ki.
Double-chimney technology for treating secondary type I endoleak after endovascular repair for complicated thoracic aortic dissection  Rui Feng, MD, PhD,
Reply Journal of Vascular Surgery
Chung-Dann Kan, MD, Hsin-Ling Lee, MD, Yu-Jen Yang, MD, PhD 
Managing Severe Upper Extremity Ischemia from Mobile Aortic Arch Thrombus: A Novel Approach Using Isolated Limb Perfusion with Tissue Plasminogen Activator 
Isolated celiac artery dissection
Proximal aortic perforation after endovascular repair of a type B dissection in a patient with Marfan syndrome  Jasper W. van Keulen, MD, Frans L. Moll,
Thrombotic mesenteric ischemia due to aortic dissection
Total aortic repair in Marfan syndrome using stent grafting with hybrid techniques  Yosuke Takahashi, MD, PhD, Yasushi Tsutsumi, MD, Yukitoshi Shirakawa,
Unknown pages in the history of vascular stent grafting
David L. Dawson, MD, Jennifer Meyer, RCIS, Eugene S
Recreational weight lifting and aortic dissection: Case report
The Impact of Intimal Tear Location and Partial False Lumen Thrombosis in Acute Type B Aortic Dissection  Apoorva Girish, MD, Muralidhar Padala, PhD,
Derek P. Nathan, MD, Edward Y. Woo, MD, Ronald M. Fairman, MD, Grace J
Extended use of computed tomography in the management of complex aortic problems: A learning experience  Larry R. Williams, M.D. *, William R. Flinn,
Type B aortic dissection after endovascular abdominal aortic aneurysm repair causing endograft collapse and severe malperfusion  Vikram Iyer, MD, Mark.
Assessment of abdominal branch vessel patency after bare-metal stenting of the thoracoabdominal aorta in a human ex vivo model of acute type B aortic.
Glenn C. Hunter, M.D., Stan N. Carson, M.D. 
Bhagwan Satiani, MD, MBA, Thomas E. Williams, MD, PhD, Michael R
A novel percutaneous double-lumen stent graft technique for treatment of chronic type B aortic dissection under local anesthesia  Sophie Wang, BS, Mahmoud.
Luke S. Erdoes, MD, Timothy P. Milner, MD  Journal of Vascular Surgery 
Endovascular repair of a type B aortic dissection with a ventricular septal defect occluder  Guangqi Chang, MD, Huishen Wang, MD, Wei Chen, MD, Chen Yao,
Percutaneous fenestrated endovascular aortic graft treatment of aortocaval fistula with aortic pseudoaneurysms secondary to penetrating trauma  Sheila.
Retrograde ascending Stanford B aortic dissection complicating a routine infrarenal endovascular aortic reconstruction  Apostolos T. Mamopoulos, MD, Thomas.
Presentation transcript:

Tear size and location impacts false lumen pressure in an ex vivo model of chronic type B aortic dissection  Thomas T. Tsai, MD, Marty S. Schlicht, MS, Khalil Khanafer, PhD, Joseph L. Bull, PhD, Doug T. Valassis, BSE, David M. Williams, MD, Ramon Berguer, MD, PhD, Kim A. Eagle, MD  Journal of Vascular Surgery  Volume 47, Issue 4, Pages 844-851 (April 2008) DOI: 10.1016/j.jvs.2007.11.059 Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 1 A, Type B aortic dissection with a patent false lumen maintained by proximal and distal tears. B, Type B aortic dissection with partial thrombosis of the false lumen. The laminar thrombus can be seen occluding the distal tear. C, Type B aortic dissection with proximal stent graft and patent distal tear. Journal of Vascular Surgery 2008 47, 844-851DOI: (10.1016/j.jvs.2007.11.059) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 2 Schematic of ex-vivo circulation. Journal of Vascular Surgery 2008 47, 844-851DOI: (10.1016/j.jvs.2007.11.059) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 3 A, Photograph of dissection model. B, Photograph of dissection model in cross-section. TL, true lumen; FL, false lumen; a, true lumen wall thickness = 3 mm; b, dissection flap wall thickness = 2 mm; c, false lumen wall thickness = 1 mm. Journal of Vascular Surgery 2008 47, 844-851DOI: (10.1016/j.jvs.2007.11.059) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 4 Dissection model configurations. Model A, Proximal and distal tear. Model B, Proximal tear only. Model C, Distal tear only. Journal of Vascular Surgery 2008 47, 844-851DOI: (10.1016/j.jvs.2007.11.059) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 5 Pressure waveforms. A, Dissection model A with 6.4 mm proximal and 6.4 mm distal tear. B, Dissection model B with proximal 6.4 mm tear only. C, Dissection model C with 3.2 mm tear only. Journal of Vascular Surgery 2008 47, 844-851DOI: (10.1016/j.jvs.2007.11.059) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions