Integrated gateway-server PowerLogic EGX300 Integrated gateway-server
PowerLogic EGX300 Integrated gateway-server Use your existing Ethernet network to access basic electrical system data View data with only a web browser, no power monitoring software needed Log data onboard the EGX300 for historical system analysis View device data through a simple browser – no software needed EGX300 web page Trend plots Data log files EGX100 EGX300 Pull information into web pages from other PowerLogic gateways (PM8ECC, EGX100) ION 6200 PM800 Micrologic Sepam
Benefits Get a complete view of your electrical system including: Meters Circuit breaker control units Protective relays Motor controllers Drives Operating on an existing Ethernet network, the PowerLogic EGX300: Helps lower installation costs Accesses multiple Ethernet devices and gateways across the network and logs data from connected devices Offers high performance and reliable communication Simple Ethernet connection with minimal configuration required Provides easy system expansion: Dynamic device additions Is compliant with industry standards (UL, CSA, FCC, CE)
Benefits View real time data using only a web browser Analyse basic data from your electrical distribution system for cost allocation and trending reports Use the embedded web page creation tool to customise your system data views and add additional devices Detect devices throughout the system with device Autodiscovery tool
Benefits Functions as a gateway from Ethernet to serial line devices Connects up to 64 devices per gateway Offers field upgradeable firmware Features Modbus TCP/IP address filtering Features 256 Mb for onboard data logging Workstations Modbus TCP Web browser PLC Master Example: PLC allowed access One workstation not allowed access Level of access configurable for read-only or full access Modbus TCP/IP Filtering Feature controls access to critical devices Modbus serial line critical control devices
EGX300 user interface – home page Easy navigation toolbar Customisable home page. Set up to view Monitoring, Control, Diagnostics, Maintenance, etc.
EGX300 user interface – per device View real time data per individual device
EGX300 user interface – per device View logged data per device
EGX300 user interface – summary views Overview of all connected devices Overview of all connected devices Overview of load current of all devices Overview of demand current all devices
EGX300 user interface – summary views Overview of power for all devices Overview of energy for all devices
Exterior features RJ45 Ethernet port (IEEE802.3af) Control power: 24 Vdc or Power-over-Ethernet (PoE) LED indicator for power & status Recessed reset button LED indicators for Ethernet and serial communications
Bias, Termination, and 2-wire / 4-wire jumper switches Exterior features RS485 serial port Bias, Termination, and 2-wire / 4-wire jumper switches RS232 serial port (RJ45 connector)
Technical highlights Ethernet Serial Environmental 10/100BaseTX Concurrent ModbusTCP/IP connections: 64 Serial All lines optically isolated for high reliability in industrial networks Protocols: ModbusRTU, ModbusASCII, Powerlogic (SY/MAX), Jbus Environmental Operating temperature: -25o to 70oC Enclosure: Din-rail mount IP rating: IP30
EGX300 user interface – setup Easily set up the media type and Ethernet IP parameters. Easily set up the media type and serial parameters.
EGX300 user interface – device discovery The Autodiscovery feature detects devices automatically and allows you to customise device names, saving you time.
EGX300 user interface – setup Customise device names
EGX300 user interface – setup Device Logging Set logging intervals and choose from a customisable list of logging topics. Log up to 10 topics.
EGX300 user interface – setup Password protection and controlled network access ensures data and system security.
EGX300 user interface – setup Customise network access to individual web pages.
EGX300 user interface – setup Support standard MIB II for SNMP only
EGX300 user interface – data logging Choose to receive the most up-to-date data or all data sent via email or ftp
Accessory: Configuration kit (TCSEAK0100) Allows configuration via RS232 serial or Ethernet port Kit contents: RJ45 to DB9F adapter CAT5 Crossover cable, 3-meters (10-feet), orange Instruction sheet
Accessory: PoE Injector (TCSEAV0100) Typically, the largest cost associated with installing a gateway into an existing installation is the cost to provide control power The Power Over Ethernet (PoE) standard (IEEE 802.3af) defines how control power can be provided to an end device through a standard CAT5 Ethernet cable PoE eliminates the need for Control Power Transformers, disconnects, and AC-DC power supplies while greatly reducing installation time Kit contents: PoE midspan injector Universal power cord, 2 meters Plug adapters for Australia, Europe, UK, USA CAT 5 Ethernet patch cable, 2 meters Instructions
For more information … Please visit www.PowerLogic.com