Synthesis of Heat Exchanger Networks Part 6 Synthesis of Heat Exchanger Networks
6.2 Simultaneous Synthesis MINLP Model
Superstructure
Special Features Objective function = annualized area cost + annualized fixed unit cost + utility cost. Objective function is nonlinear, but constraints are linear. Within each stage of the superstructure, potential exchangers between every pair of hot and cold streams can occur. It is assumed that the outlets of the exchangers are isothermally mixed, which simplifies the calculation of the stream temperature for the next stage, since no information of flows is needed in the model!!! The outlet temperatures of each stage are treated as variables. The isothermal-mixing assumption can be relaxed.
Special Features In most cases, it is OK to select the number of stages as the maximum of hot and cold streams. The use of by-passes and split streams with 2 or more matches in each branches is not included in superstructure. A major advantage of this model is its capability of handling constraints for forbidding stream splits.
Overall Heat Balance for Each Stream
Heat Balance at Each Stage Note that no variables are required for the branch flows due to the isothermal mixing assumption!
Temperature Constraints
Hot and Cold Utility Loads
Logic Constraints
Temperature Approach
Objective Function
Example 3 Stream Tin (K) Tout Fcp (kW/K) Heat Load (kW) h (kW/m^2K) Cost ($/kW-yr) H1 440 350 22 1980 2.0 - C1 349 430 20 1620 C2 320 368 7.5 360 0.67 S1 500 1.0 120 W1 300
Solution Obtained with Sequential Approach
Design without stream splits