Alpha Tiny Giants lpha lpha Controller. Alpha Product Overview Programming Overview System sketch Ancillary Items Summary.

Slides:



Advertisements
Similar presentations
1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
Advertisements

Yokogawa Network Solutions Presents:
CL100D series DSP controlled Uninterruptible power supplies.
Dc input modules can either be sources or sinks for dc current. This depends on the transistor used in the input card and the polarity of the dc supply.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
By Michael Ashman David Insel
MASTER QUOTE OVERVIEW.
Unit 7 Discrete Controllers
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Programmable Interval Timer
© Paradigm Publishing, Inc. 2-1 Chapter 2 Input and Processing Chapter 2 Input and Processing.
KX-NS1000 Initial Set Up For step by step : 16 May,
Advanced Workgroup System. Printer Admin Utility Monitors printers over IP networks Views Sharp and non-Sharp SNMP Devices Provided Standard with Sharp.
Chapter 10 – Digital System Projects Using HDL Copyright © 2011, 2007, 2004, 2001, 1998 by Pearson Education, Inc. Upper Saddle River, New Jersey
PYRO-STAG De-Icer Optimizer Controller Technical presentation 2013.
Drawer 8/16 Port Combo-Free IP KVM Console with 17" LCD Display
The different controllers The Functions Input functions Function blocks Dedicated function blocks Logic functions Output functions Applications Examples.
Counter Circuits and VHDL State Machines
Aeroponic Irrigation System James, Chris, Ewan
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
ASPPRATECH.
Programming with Function Blocks
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
Advantages of using R.PC.R Software Now that you know some of the advantage let’s take a look at the software … Reliable and Comprehensive Reporting Recording.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
Programmable logic control Data Processing Computer System Key Board Light Pen Mouse PLC a Process Control Computer System Motion Sensor Sound Sensor.
Looking for a more powerful circuit monitor?
Operator Panel and Programmable Logic Controller.
ENVIROTRAC: A Premier Chamber Monitoring and Data Acquisition System Envirotrac A Guided Tour.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Learning Targets Identify the external parts of the computer Identify examples of input devices Identify examples of output devices Define basic computer.
PowerFlex 755 DeviceLogix
8254 Programmable Interval Timer
Single Loop Analogue addressable fire control Panel
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
Industrial Process Control System Simon Hui Engineer Control and Informatics, Industrial Centre.
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
The 8253 Programmable Interval Timer
School of Computer Science G51CSA 1 Computer Systems Architecture Fundamentals Of Digital Logic.
Introduction to Robo Pro
System Overview The Perfect Solution For Small ‘Entry Level’ Access Control Applications August 2014.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
©2008 Pearson Education, Inc., Upper Saddle River, NJ. All rights reserved. This material is protected under all copyright laws as they currently exist.
CENT-113 Digital Electronics 1 Flip Flops TI Type 502 Flip Flop: 1st production IC in 1960.
Programmable Logic Controller (PLC)
MSI Counters Counter ICs Technician Series ©Paul Godin Updated Feb 2015 gmail.com.
Chapter 7 Data Sampling Screen Otasuke GP-EX! Chapter 7 Data Sampling Screen.
Time Management.  Time management is concerned with OS facilities and services which measure real time.  These services include:  Keeping track of.
0 Configuring a 3500 Using iTools 2 iTools Workshop - getting started Start iTools and from the New File menu choose 3504 v1.04 programmer.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
1 ALARMLINC. 2 OVERVIEW Expanding Situational AwarenessOVERVIEW.
C1300 advanced circular chart recorder
SCADA for Remote Industrial Plant
Digital Fundamentals with PLD Programming Floyd Chapter 10
Programmable Logic Controllers (PLCs) An Overview.
Lecture Number 4 Siemens S7.
ABB Graphical display for UPS
Programmable Interval timer 8253 / 8254
Programmable Interval timer 8253 / 8254
8253 – PROGRAMMABLE INTERVAL TIMER (PIT). What is a Timer? Timer is a specialized type of device that is used to measure timing intervals. Timers can.
FLIP-FLOPS.
Programmable Logic Controllers (PLCs)

Presentation transcript:

Alpha Tiny Giants lpha lpha Controller

Alpha Product Overview Programming Overview System sketch Ancillary Items Summary

Alpha Product Overview RETURN Basic hardware features Size / Installation Input / Outputs (I/O) devices

Alpha Basic hardware features Inputs Outputs Programming from the front of the Alpha (with 8 keys & LCD-display) Power supply Interface for PC-Programming Interface for memory cassette Programmable operator interface (LCD-display) Direct mounting

Alpha Inputs Outputs ModelInputsOutputs 6 I/O Alpha42 10 I/O Alpha64 20 I/O Alpha128 Basic hardware features Options - model sizes: Options - power supply model: –24V DC –100 to 240V AC (50/60Hz) Options - expandability: –Network slave cards ex. AS-I (20 I/O Alpha only)

Alpha Input / Outputs (I/O) devices Options - Inputs: –Models with 24V DC power supply 24V DC inputs (digital) Up to 8 digital inputs can be re-designated through system software as being analogue inputs –Models with 100 to 240V AC power supply V AC inputs (digital) Options - Outputs: –Relay models - 8A per point at 240V AC / 24V DC –Transistor models - 1A per point at 24V DC

Alpha ModelWidthHeightDepth 6 I/O Alpha 10 I/O Alpha 20 I/O Alpha124.6 mm 55 mm90 mm 71.2mm Size / Installation Compact size: –(DC powered and AC powered units are the same size)

Alpha Size / Installation

Alpha Size / Installation Options - installation: – Directly on to DIN-rail – Directly on to the surface (by screws/bolts through integrally moulded location holes)

Alpha Size / Installation Direct mounting - using screws Direct mounting - using DIN-rail

Alpha Programming Overview Basic programming features Available instructions Software RETURN

Alpha Basic programming features Function (block) based programming Programming directly from the front of the Alpha –Graphic LCD-Display –8 keys –Menu driven operation –System operation available in 5 languages (English, French, Spanish, German, Italian) –All information of one function block is displayed simultaneously Option - Windows based software (95, 98, NT)

Alpha Programming directly from the front Monitoring LCD-Display & 8 keys Menu driven operation All function data displayed simultaneously

Alpha Digital inputs Digital input Analog input Analog values / special outputs / display outputs Digital output Programming basics Programming is function (block) based Each function is easily selected Each function (block) carries out one task which has a number inputs conditions and resultant outputs Up to 64 function scan be linked together (or up to 1500 bytes - which ever is exceeded first) Each function (block) can be used as many times as required

Alpha Software - ALVLS The software is called AL-PCS/WIN (ALVLS - Alpha Visual Logic System) ALVLS works under 95, 98 and NT ALVLS is a graphic based software which is available in 5 different system languages (English, French, Spanish, German, Italian) Programming is possible with no previous experience –There is a system Wizard (to help create basic programs) –There are on line guides (to help use software functions) Programming is based on selecting graphic icons which represent functions, placing them in a work area and connecting them up with a line. –There is an extensive help system (to provide general support)

Alpha Software - ALVLS Icons can be personalised, I.e. users can add or customise their own All programs can be simulated: –On-line simulation and monitoring requires the Alpha unit to be connected to the PC –Off-line simulation requires no Alpha unit as everything is self contained in the ALVLS software ALVLS programs can be completely documented with comments for functions and added generic comments ALVLS has a system sketch mode which allows users to create their own PC based operator interface

Alpha Software - ALVLS

Alpha Buttons Internal Bits Scroll selection Inputs Input menu selection Software Input signals Automatic identification of digital or analogue inputs depending upon the selected input image

Alpha Example, Analog Input Analogue or special signal is represented by green dot Analogue signal is shown with a thicker connection line Software Input signals Analogue signals – Up to 8 inputs can be defined as analogue – Analogue input is 0 to 10V DC – Analogue resolution is 8 bits (0 to 255) – Analogue inputs are only available on 24V DC powered units

Alpha Output types Scroll selection Output menu selection Software Output signals Graphical symbols and images make programs easier to understand

Alpha Software graphical program simulation Programs written with ALVLS software can be simulated to ensure correct operation. Input/Outputs status is toggled with line and function block status.

Alpha AND (And-Link) OR (Or-Link) NOT (Negation) NAND (And-Link negated) NOR (Or-Link negated ) XOR (either/or) Instructions - Logic signals Simple boolean commands

Alpha Word or symbol logical operators Simulation Easy to understand sentence construction Instructions - Logic signals Complex boolean instructions can be created using the BOOLEAN function

Alpha Instructions - Status control Self retaining command SET-RESET: –SET (set), RESET (set back) –Setting of priority Status alternate (flip) ALT: –It function toggles the output whenever the input signal changes from OFF to ON. When clear input is ON, output becomes OFF irrespective of input status. Time-function ONE-SHOT: –Time range 0.1 s– s –This function is used to generate a single pulse with a specific duration

Alpha Instructions - Status control Time function DELAY: –T ime range 0.1 s– s –Switch on-delay (on-delay) –Switch off-delay (off-delay) –Switch on- and off-delay timer, duration's can be set separately Pulse generator function FLICKER: –Time range 0.1 s– s –Pulse generator asymmetric (T-on, T-off individually adjustable) –Number of pulses adjustable or continuously –Total time of pulses adjustable or continuously Time function PULSE: –Generates a pulse for one cycle when the following are selected: leading edge of one input trailing edge of one input leading and trailing edge of one input

Alpha Instructions - Event monitoring Maintenance function HOUR-METER: –Next maintenance time is set - when reached an output is activated – Counting of working hours and minutes up to hrs and 59 min (1365 days, 3.7 years) – Counter value kept for 20 days after power is removed – Can be cascaded to increase time base Counter function COUNTER: – Counting range up to – Output set when Count value reached – Count can be reset by input at any time Counter function UP/DOWN-COUNTER: – Counting range: – – Up/Down inputs are separate – Output set when Count value reached – Count set value can be manual setting, analogue input or fixed value triggered by digital input – Count can be reset by input at any time

Alpha Example : Tuesday, h30 Example : Tuesday, h Instructions - Event monitoring Real time clock function CLOCK: –Data available from the real time clock: hours, minutes, day of the week, day of the month, month, year –3 Formats to display the date: dd.mm.yyyy mm.dd.yyyy yyyy.mm.dd –Direct adjustment of the clock on the unit –Automatic adjustment of day and week –Automatic summer time/daylight saving time (US, UK, EU presets plus user configured option) –Max. 350 time events

Alpha Instructions - Value processing Analogue value processing GAIN: –Adjust Gain/Offset of read analogue values –Apply scaling to analogue input values Compare-function with words COMPARE: –Comparison of 2 values (could be analogue, counter or timer values) –Types of comparison: =, <>, >, >=, <, <= Schmitt-Trigger SCHMITT – Comparison of a value to 2 set points triggering different actions Zone Compare (range on/off) ZON-CMP –Comparison of a value to a range (could be analogue, counter or timer values) –Types of comparison: =, <>, >, >=, <, <=

Alpha Instruction - User Interaction HMI-Function DISPLAY: –LCD-Display on Alpha: 4 lines x 10 characters –The contents of display can be freely programmed with text and/or values from programmed functions –Displayed values can be easily changed/edited using the keys on the front face of the unit

Alpha Instruction - User Interaction To change a value through the HMI/Display option: –Press key: –First value is signaling –+1 at value, key –-1 at value, key –Confirming of change, key –Should the display consist of several values, selection of values with or with

Alpha System sketch RETURN

Alpha System sketch ALVLS software, Monitoring in System Sketch: –In the ALVLS software it is possible to carry out monitoring and/or simulation –Within the System sketch area, users can create a visual representation of their application (effectively creating a low function SCADA system) –Images can be imported (BMPs) and links to standard Windows programs can be made –Users can copy any of the inputs/outputs or functions used in the Alpha program to the System sketch area –By placing the devices in the System sketch and then activating either the simulation or the monitor modes - the users program can be controlled directly E.g………………..

Alpha System sketch

Alpha Ancillary Items RETURN

Alpha Ancillary Items The ALVLS software communicates to the Alpha unit through the computers serial port. This is connected to the Alpha unit with the AL-232CAB cable as shown below.

Alpha Ancillary Items Memory cassettes: –By insertion of an EEPROM-cassette a new Alpha program can be directly inserted without a programming tool Alpha has been designed to suit users needs: –Industry (IEC , 2) –House- and building technique (EN 60730) –CE EMC –CE low voltage –UL/cUL.

Alpha Summary RETURN

Alpha SUMMARY Mitsubishi Electric, world leader in the sector of small PLCs launches something new on the market: The Alpha-Controller Smaller and cheaper than a PLC, but with a lot of perfomance and new possibilities: A totally innovative way of programming via the Alpha software A big range of integrated functions –Display-Function –Outputs for up to 8 A –Real-time clock function –Standard analog inputs and corresponding functions. Alpha, Leader of the Function Controller Generation

Alpha Questions? Alpha

Tiny Giants lpha lpha Controller