Rep Training 2015 Ben Coutee

Slides:



Advertisements
Similar presentations
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Advertisements

Flange Protection Band. Flange Protection Band.
Presentation of ELIS PLZEŇ a. s. The Czech Republic Es 90349K/b.
Severe Service Metal Seated Ball Valves
Guided Wave Radar Pros and Cons
Welcome to Bumgarner Welding & Inspection, Inc. Washington, IN
Hydraulics.
Gas Transmission Pipelines
Welcome to the HYCOA Solution
ACADs (08-006) Covered Keywords Calibrate, direct, inferred, transmitter calibration, gravity correction, density correction, hydrostatic head detector,
NorCal Tech 2005 Technical Conference
Objective : To understand the fabrication, design, installation welding, inspection and testing for new construction in oil and gas industry After followed.
STEAM HEATING.
Mechanical for Oil Heat
…an innovative shell and tube heat exchanger with an exceptionally high heat transfer coefficient for industrial fluid cooling and air conditioning.
Submersible Seal Top Down DP Level Assembly. DP Level Solution for Top-Down Level Measurement Applications Challenge: Many tanks go un-instrumented in.
EESIFLO International Pte Ltd
HVAC523 Circulator Pumps.
Chapter 22 Industrial Process Piping. Learning Objectives After completing this chapter, you will –Describe different types of pipe and their respective.
Plan 2 – Dead-end Seal Chamber Optional Jacket
Wedge Flow Element 1.
INTRODUCTION Definition:
Mechanical Design Of Process Equipment.
FAA/NASA Joint University Program for Air Transportation Research Jeff Dickman Chris Bartone June 20, 2003 A New Anechoic Chamber for Nearfield Antenna.
Heating Systems.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
Simple Water Level Controller Circuit with Microcontroller and Alarm.
1 Field Devices – Sales and Marketing Conference – April 2015 Field Devices 2014 BR - Confidential 1 Field Devices Foxboro® “S” Series Pressure April 2015.
Replacing Displacers with Guided Wave Radars
SAL COLLEGE OF ENGINEERING AHMEDABAD LIQUID LEVEL MEASUREMENT
Government Engineering College Bharuch(014). Sub: Instrumentation And Process Control. Topic: Displacement float,Pneumatic balance and Magnetic level.
Ryan Kane.  Storage tank provides water for eleven stock water tanks on the ranch.  Well pumps water up to storage tank.  Water gravity flows down.
 SIO Trunnion Mounted Ball Valve are designed and manufactured as per ASME B 16.34/BS5351/API6D/B S EN 17292/ISO
Line Blinding/Blanking Options
Innovative Testing & Engineering Solutions for the Industry
Exhaust Heat Recovery Systems
Chemical Engineering Drawing
By ASST. Prof. DR. ASEEL BASIM
Magnetic Impelled Arc Butt Welding
GROUND SERVICING OF VARIOUS SUB SYSTEMS
Product Profile, Features and Options
Heating Ventilation and Air Conditioning
INSULATION FOR INDUSTRY AND HOUSING
Copyright SwissFlow B.V.
How SCADA Systems Work?.
Asahi/America Electric Actuators Series 94.
Nondestructive Testing
Industrial Instrumentation: Transmitters
Parul Institute of Technology
OH3 or OH5 Direct Drive API 610 Centrifugal Pumps
Subsea 100 Global Services Products Presentation
Magnetostrictive Liquid Level Transmitter
THE SKINNER COMPANY Product Review
SB Packing Automatic Downpuller Power Unit
Vertical Pressure Filters
Hot water Systems Heaters.
Welcome! Drafting 2323: Pipe Drafting
Asahi/America Electric Actuators Series 94.
Piping and Instrumentation for Process Industries
QTS Webinar Magne-Trac updates
GLASS-TRAC LIQUID LEVEL GAGES & VALVES
The perfect fit for corrosive wet areas Maintenance Units, Series MH1
Glass-Trac Model Breakdown
Day 2 Training - Technical
FLOWTECH PRODUCTS LLP “PIONEERS IN FLOW CONTROLS & MEASUREMENTS”
Boiler Safety Valve Regulations
SCITEQ End closure series
Gas Transmission Pipelines
Presentation transcript:

Rep Training 2015 Ben Coutee Magnetic Level Gage Rep Training 2015 Ben Coutee

Topics Capabilities Overview Product Offering Bridle and magnetic level gage standards Magneostrictive vs. GWR Testing (NDE) Applications Questions?

Product capability A complete line of MLI, bridle and instrument solutions Design, engineering, and integration for all systems Piping, welding and instrumentation expertise Top tier support for product The magnetic level gage is an engineered solution!

Product offering

Product Offering Replacement of sight glass 8 basic styles with customized options Sold as an engineered product Best lead times in industry Low maintenance option for end users Highly visible (200 ft) Customizable options Magnetic Level Gage

Product Offering Send a signal back to the control room indicating level (Continuous) Current pulse from transmitter start pulse Interaction of pulse and magnetic field causes a torsional wave return pulse Time between start pulse and return pulse is proportional to position of float MLI + Magneostrictive Transmitter

Product Offering Continuous level measurement back to control room Used as separate instrument from MLI Higher temp/pressure capabilities Dual Chamber design GUIDED WAVE RADAR is based upon the principle of TDR (Time Domain Reflectometry). Pulses of electromagnetic energy are transmitted down a probe. The pulse is reflected when it reaches a liquid surface. MLI + Guided Wave Radar

Product Offering Level Switches Quest-Tec level switches are hermetically sealed, non-mercury, bi-stable latching switches designed for use with Magne-Trac level gages. The bias magnet design latches the switch maintaining the contact after the level continues to rise or fall. The switch will change state when the float magnet passes by. The switches are fully adjustable and non-invasive. Level switches are mounted to the Magne-Trac chamber with all 316 Stainless Steel worm gear pipe clamps. Switch points can be changed easily at any time without any interruption to the visual indication or process. Available in 1, 5 & 10 AMP Level Switches

Product Offering Insulation (HB) Cryogenic Insulation (CI) Steam Trace (ST) Electrical heat trace (EH) Freeze Protection (FP) Isolation valves (IS) Vent/drain valves (VD)

4 Key Factors in Quoting!! Specific gravity / Process fluid Maximum/Operating Pressure Maximum/Operating Temperature Center to Center Dimension

Specific Gravity/Process fluid Why both? Essential pieces of information that feed into the overall design of the gage. Will directly affect the float design, chamber size and dimensions of “dead” zone. Specific gravity vs. chamber design

Pressure / Temperature Considerations Having a direct affect on the specific gravity of a process fluid, knowing the operating pressure and temperature is essential to overall design. Pressure can change sizing of the chamber during specification Temperature can be limiting on the type of technology available and needs to be taken into consideration in all applications (cold or hot) Flag material will change in high temp scenario Look for process media that solidifies at certain temperature and offer heat tracing options or freeze protection

Float Design (Oblong) Oblong available in 316, titanium, CPVC, hastelloy C and carbon fiber 316 SST floats are .020” wall thickness and used in applications up to 400 PSI SG range is .60 and up 360 DEG ring magnet Most common used float Can easily be replaced (within a few hours)

Float Design (Spherical) Titanium material Designed to handle up to 2800 PSI Will directly affect sizing of the chamber May be necessary under .60 depending on pressure/temperature Will affect the overall length of the gage (be mindful of sizing limitations)

Chamber Design Standard chamber is 2” SCH 40 Available options: 2” SCH 40, 2.5” SCH 80, 3” SCH 40 & 3” SCH 80 QTS does not do any SCH 10 (is this a limiting factor?) Material options: 304 SST, 316SST, Hastelloy C, CPVC, Monel and PVDF (Kynar) Material combinations? Full bore process connections available (no pulled extrusions) Vent / Drain connection types

Flange class process connections

Process Connections SW - Socket Weld RF – Raise Faced Flanges RJ/RTJ – Ring Type Joint (Gasket) WN – Weld Neck SO – Slip-On LJ – Lap Joint (not common)

Branch Connection Reinforcement

Vent / Drain All MLI’s require a flanged end to install the float. Drain Plugs: ½”, ¾” or 1” NPT / SW 316 SS (or like material) Vent Plugs – ½”, ¾” or 1” NPT 316 SS

Wide Flag Indicator High Temp Molded Nylon Flags Non-Corrosive / Low Friction Molded in Color, UV Resistant Black=Vapor, Yellow=Liquid 1.4’’ design provides greater visibility and magnetic field attachment Heavy anodized aluminum housing (Stainless steel housing available) Sealed with 4 “O”-Ring beads Polycarbonate shield: Glass option available 316 SS photo etched scale option (inches, MM, %....available) Note indicator viewing position

3 Main Parts Chamber Indicator Float

Magneostrictive transmitter Use as a SYSTEM 4-20 mA loop powered transmitter HART communications Explosion proof (all classes available) Optional Digital display Lengths from 20” to 25’-”dead leg” Temperatures to 257º Excellent redundancy device Easily attaches to the exterior of Magne-Trac Set it and forget it—rarely needs calibration or maintenance

Guided Wave Radar

Guided Wave Radar Separate Chambers allow for unimpeded float travel- “dead leg” GWR not influenced by process conditions- true level measurement High temperature applications: pressure and temperature has little effect if any Temperatures to 750º Pressures to 5800 psi HART, PROFIBUS, and FOUNDATION fieldbus available Can be used in conjunction with Magneostrictive transmitters

Welding and documentation standards Follows ASME B31.1 manufacturing codes Certified Welders and Welding Certificates ISO 9002:1000 Certified WPS – Weld Procedure Specification Material Specific Procedures PQR – Procedure Qualification Records Material Specific Records Hydro Testing Records Chamber Tested at 1.5x Maximum Operating Pressures Float Tested at 1.25x Maximum Operating Pressures NACE Certifications Primarily concerned with H2S Service MR0175

Testing PT/LP – Liquid (Dye) Penetration Inspection Done in-house at QTS Level II inspectors on staff VT – Visual Inspection MT – Magnetic Particle Inspection Material needs to be magnetic 3rd Party independent lab RT – X-Ray/Radiographic Inspection UT – Ultrasonic Inspection LT – Air or Water Pressure Testing DT – Destructive Testing

Not so common applications HF Acid in refineries Sour Crude Oil tanks Gas / Liquid separators Oil seal reservoirs Sodium Hypochlorite tanks Caustic Soda Acid Storage tanks Boiler feed water Compressor oil sump level

Field Considerations Dirty service How does dirty service affect a magnetic gage and its field use How do we combat the issues associated with dirty service?

Field Considerations Flashing Oversized chamber principle much like what's offered in dirty service Guide rods Insulation?

Field Considerations Interface applications There are many applications where the interface between two immiscible liquids must be monitored or controlled. These involve oil and water separators, wastewater disposal tanks and a multitude of chemical processes Mags can be used with a specially weighted float that will sink in the top layer and float in the bottom layer provided there is a specific gravity difference of 0.1 between liquids

Field Considerations Boiler Drum level If the plant is adhering to PG60 special consideration needs to be taken in magnetic gage specification A magnetic gage can only be used up to 900 PSI A magnetic gage falls under “remote level indication” not direct reading sight glass Great chance to use multiple “remote level indicators” off one set of taps

Kynar Level Gages Frequently a level gage application requires the wetted parts to be hastelloy, zirconium, titanium or other exotic material because of a highly corrosive nature. As a cost savings we can offer gages made from solid Kynar. The material is similar to Teflon but is less porous. It is limited by a temperature of 280 DEG F. It is only about 25-30% more than stainless but about half the price of a hastelloy gage

Gages in the Food Industry QTS has a gage that can be “3A” approved for use in the dairy industry. Anyone in the food industry generally recognizes this approval and the “3A” symbol. Whether it is brine, vinegar, beer, vegetable oil or mile products they want to have a sanitary version of the MLI.

Pump up / Pump down Various types of process tanks frequently need some type of automatic level control. Receiver vessels need to be pumped to storage when they become full (pump down) and feed tanks need to be refilled when they become low (pump up) The QTS 3 or 5 AMP reed switch can be used in conjunction with a latching relay controller for pump up and pump down operation

Magne-Trac Specification & Model Code Guide:

QUEST-TEC SOLUTIONS MAGNE-TRAC SPECIFICATION

QUEST-TEC SOLUTIONS MAGNE-TRAC SPECIFICATION

QUEST-TEC SOLUTIONS MAGNE-TRAC SPECIFICATION

QUEST-TEC SOLUTIONS MAGNE-TRAC APPROVAL DRAWINGS

Questions?