GOODSON Tools and Supplies for Engine Builders Calibrating and Maintaining Your Precision Machinists Level.

Slides:



Advertisements
Similar presentations
Sectional Assembly and Installation
Advertisements

Goodson Tools and Supplies for Engine Builders Bronze Liners.
Goodtool Brake Service Tools and Supplies
J.P. Langston Brake Retrofit
Zebra® 105SL™ * Removing and Installing Printhead
Fasteners Mr. Lombardi. Fasteners Mr. Lombardi.
H.E. Anderson Company Maintenance Tip How to Replace a Chemical Side Diaphragm This presentation will show you how to change a chemical side diaphragm.
Engineering Drawing Lecture 3
Power Tools Safety. Portable Circular Saws Stock must be well supported in such a way that the kerf will not close and bind the blade.. Thin materials.
TWO (2) Installation principles 1. Cabinets need to be installed straight, plumb, and level. 2. The area you are working in is rarely straight, plumb,
Facing Between Centers
Aerospace Fastener Applications
RockOn! Canister Integration RockOn! 2009.
Representor: Yoo D. Moon Date : November 25, 2008.
Optical Manufacturing Solutions 1 Probe Assembly.
ZIPP 404 BEARING REPLACMENT GUIDE Tools Needed:
Click on this image to open the full PDF document.
Machining a V-Block Flexible Manufacturing Copyright © Texas Education Agency, All rights reserved. 1.
Flange-lok Installation Instructions Quick Installation Guide rev. DB.
GLOBAL LIFT CORP COMMERCIAL SERIES PORTABLE KIT Portable Kit -
Yamaha oil pump rebuild
1 STEPMILL 7000 PT ASSEMBLY INSTRUCTIONS PART NUMBER
¾”-2”. Modification Overview  Production of the series began in 1989 and is current.  Early models of ¾”-2” series did not always.
Goodson Tools and Supplies for Engine Builders
MyLock 644D Service Seminar.
Milling Machine Setups
What is a fastener? A device to locate or hold parts.
Memory Craft Feed Dog Drop Step Motor Adjustments.
Fabrication of Fishtank Platform EAS 199B living with the lab.
Stable Rise –Pull and Swivel Top Installation and Set Up Guide Jaymil Ergo & Office Solutions 150 Dow Street, Tower 4, Manchester, NH
Air tank installation instructions Included parts: Raw aluminum air tank bracket 5/16-18 button head bolts (qty 4) M8x1.25 button head bolts (qty 4) M8.
Jacto Incorporated, 9650 SW Herman Road, Tualatin, Oregon (800)
1 Zebra 170 XiIII Plus Removing and Installing Printhead Calibrating Head Resistance Print Quality Adjustments.
860 21/2”-10”. Modification Overview  Production of the 2½” – 10 sizes began in  Lead free version (LF860) was introduced in Parts do not.
Inside-, Depth-, and Height-Measuring Instruments
1- Pipsqueak Engine Millwork on uprights and base.
TOOL: Radial Arm Saw NEXT STEP: Radial Arm Saw RESULTS: Finish Top Apron Pieces at 9” L x 4” W x ¾ “ Th PROJECT Square Plant Stand PART Top Apron # NEEDED.
Drilling Holes Unit 42.
Jacto Incorporated, 9650 SW Herman Road, Tualatin, Oregon (800)
10 Easy steps to building your computer By Chris Holzworth & Michael Barnett.
1 FREE CLIMBER 4400 ASSEMBLY INSTRUCTIONS PART NUMBER
CHAPTER 33 Drum Brake Systems.
Rut ‘n’ Strut Game Calls How I turn a Pot Call. Select wood that you want to use to turn Pot Calls out of, Rip it 4” wide and then Crosscut into 4” X.
994 2½ ”- 10”. Modification Overview  Production for the 994 began in 1999 and is current.
Clearing Procedures. DISASSEMBLY Major Groups Barrel Group Turn the cover latch and raise the cover group Grasp the retracting slide handle with the.
Chapter 12: The Resident’s unit
LAB #9 Valve Head replacement. Insert the valve. Make sure that the cap goes on the intake valve. Insert the springs. Insert the keeper.
LF866 2½”-10”. Product Overview  Production of the 2½” – 10” sizes began in  The LF866 utilizes a Type 2 bypass (Model LF619 single check).
How to Change Raptor Knife Blades. Step 1: Use a Phillips screwdriver to remove the 5 screws. It is not necessary to remove the lanyard/webbing to change.
XR621 Drive Hose Update Kit. Removal Turn off Battery dis Drain hydraulic tank Remove both rubber lines under chassis and discard. Remove and discard.
Simon Calibration Instructions Main Antenna Jig Peter Karlsson V2.
Garden Box Design Plans. Garden Box Materials List QTY (Lumber)* 2”x4”x120”(10’) - Cut one of these boards into two 41” pieces and two 17” pieces.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
Description of Hand Tools Tools help us do work and make things. Tools.
VIEW SERIES with Sliding Door
Annex 4 - Moving Frame and Whiffletree assembly
Flexible Manufacturing
Tramming the Toolhead on a Vertical Milling Machine
Bilge Pump Service Project Model Service Kit
826YD 21/2”-10”.
Horizontal Milling Operations
Disassembly and Assembly of A07A-W1/W2 Electronic Governor Actuator for AD Fuel Injection Pump
How to Change a Flat Tire
¾”-2”.
W201 3R hardboard Replacement Procedure.
Drawing of stud.
LF856 2½”-10”.
880V 21/2”-10”.
Correct Procedures for Changing, Storing, and Maintaining Saw Blades
REX Regulator (KM47/77).
Presentation transcript:

GOODSON Tools and Supplies for Engine Builders Calibrating and Maintaining Your Precision Machinists Level

Toll Free: Phone: : Web site: Replacing the Vial Step One Remove the 3/8 top nut Be sure to leave the bottom nut in place

Toll Free: Phone: : Web site: Replacing the Vial Step Two Remove the slotted screw on the opposite end completely

Toll Free: Phone: : Web site: Replacing the Vial Spherical chamfered end mounts with screw and spherical washer

Toll Free: Phone: : Web site: Replacing the Vial The straight, non- chamfered hole mounts on the stud. Be sure the bottom nut is in place before placing the replacement vial.

Toll Free: Phone: : Web site: Replacing the Vial Step Three Tighten the screw to only 1 to 2 inch pounds, maximum NOTE: If you get the screw too tight at this time, you risk breaking the vial as you adjust the leveling nuts (step eight)

Toll Free: Phone: : Web site: Replacing the Vial Step Four Install the adjuster nut finger-tight at this time.

Toll Free: Phone: : Web site: Replacing the Vial Step Five Uncover the vial and prepare to calibrate the level NOTE: Always store the level with the vial covered. While replacing the level vial assembly, be careful and keep the vial cover closed.

Toll Free: Phone: : Web site: Calibrating the Level With your new level vial installed, you are now ready to calibrate the level Select a flat smooth surface. Ideally a machined surface such as the table of a guide and seat machine or head resurfacer. Clean the surface and remove any nicks.

Toll Free: Phone: : Web site: Calibrating the Level Step Six Use a pencil or Sharpie to draw a line around the level base Use this outline to place the level in the same place each time you rotate the level end to end while calibrating.

Toll Free: Phone: : Web site: Calibrating the Level Step Seven Rotate the level 180˚ (end for end) and observe where the bubble aligns each time. You will be splitting the difference as you adjust the leveling nuts.

Toll Free: Phone: : Web site: Calibrating the Level Step Eight Adjust the nuts to raise or lower the vial bubble. NOTE: Always raise and lower the nuts simultaneously. Maintain a slight locking pressure on the level mounting ear.

Toll Free: Phone: : Web site: Calibrating the Level Raise this end 1/2 of the difference (see step seven)

Toll Free: Phone: : Web site: Calibrating the Level This is the result of the adjustment made using the readings observed in step seven.

Toll Free: Phone: : Web site: Calibrating the Level Success! When you can rotate the level 180˚ (end to end) and the reading repeats, your level is calibrated. NOTE: You do NOT need to have the bubble at the center of the level for it to be calibrated. You must only repeat the reading when rotating end for end.

Toll Free: Phone: : Web site: Calibrate the Level Step Nine Snug down the fasteners. DO NOT over tighten! Check your readings to be sure nothing has moved. If it has, repeat adjustment procedures.

Toll Free: Phone: : Web site: Level Your Work You are now ready to level your work. When leveling, always back level. Rotate your level 180˚ to be sure it repeats. Its quick insurance that your level is remaining true.