1 The YL9100S HPLC All your needs for semi-preparative applications.

Slides:



Advertisements
Similar presentations
LED Drivers Al Marble Manager, Sales & Market Development January 2010.
Advertisements

1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
OXYGEN-ALTERNATE FUEL TORCH EASY SET UP June 4, 2011 Chad Koens District Manager
Clarity Chromatography Software
Filters and Enveloping - A Practical Discussion -
Single-use Quantasep Systems First Bench-top Single-Use flow- path Chrom System with gradient capability.
3G Monitor. 3G Camera Contents 3G camera Function Features 3G Camera's Application Scenes 3G camera's business mode 3G Camera Technical parameters.
CLEAN FORMAT FASTER NAVIGATION PRODUCT SELECTION GUIDES UPDATED INFORMATION WEBSITE ENHANCEMENTS.
Convection Temperature Device
THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development Acme INNOVATIVE YL6500GC.
An introduction to Ultraviolet/Visible Absorption Spectroscopy
ERA SOLAR PRODUCTS ERA Renewable Energy. Solar energy is the ultimate source of energy from millions of years and it is a renewable energy. This energy.
Think Smart Work Better
Chem. 231 – 3/4 Lecture. Announcements I Set 1 Lab Reports –Both Lab Reports due 3/13 –Only one of the lab reports needs to be detailed, the other can.
For Large Scale Purification
Comments on the gas system Issues of scale What gas mix? Summary Karol Lang The University of Texas at Austin NuMI Off-axis Experiment Detector Workshop.
Teledyne Isco Confidential
SITOP power facets A&D SE PS SITOP power Automation and Drives SITOP power flexi The power pack handles it all - from 3 to 52V SITOP power.
HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd.
1 Kraft Fuels LPG Products & Services Your Logo Here Franz Keiling An Overview about LPG Dispensers and Technology Franz Keiling An Overview about LPG.
Compact & Perfect for Your Satisfaction
Christian Gotenfels.
Introducing the EASY-nLC™
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Introduction to the HPLC ChemStation and Acquisition.
High Performance Liquid Chromatography
Flash Chromatography 150 & 300 ml/min Flash Pumps New 200 ml/min Binary Flash Pump.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
High Performance Liquid Chromatography Instrumentation.
ProStar 210/218 Solvent Delivery Modules
Diagnostics – Quaternary Pump & Fraction Collector Analytical 920 LCSemi-Prep 940 LC.
Varian 920-LC Integrated Analytical HPLC
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
900-LC P. van Poppel – Field Support Specialist October 2009.
Varian 900-LC Series iHPLC
VARIAN, INC. HPLC Products
HPLC Instrument Manager, Europe Region 1
1 Varian 940-LC Analytical to Prep HPLC. 2 Varian 940-LC Silver Bullets The 940-LC one instrument – many uses: –High performance automated Analytical.
Analysis of Ibuprofen in Tablets According to the US Pharmacopoiea using a Varian 920-LC Analytical HPLC and Pursuit ® XRs column By Phuong Truong Varian.
Sales Objections and FAQ’s 940-LC Analytical to Preparative Systems.
Comparison of Competitor
The 900 series LC Analytical 920 LCSemi-Prep 940 LC.
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
Varian Integrated HPLC Systems (iHPLC) Frankie Button HPLC Instrument Manager, Europe Region 1 November 2007.
SSI Binary Gradient Pump Modular Simplicity. Ideal Gradient Characteristics Modular design Small foot print Easy Maintenance Compatible with stand alone.
Introduction to training
212-LC Pump Technology Background August Dual Piston Pump Single piston pumps deliver then refill, forcing the use of a very large pulse damper.
Best Broken into four categories
Waters HPLC Competitive Review
Varian 920-LC Competitors. 2 Varian 920-LC Market Competitors Competitors Shimadzu Waters Agilent Dionex The 920-LC presents a significant step forward.
RECENT DEVELOPMENT IN SUM FREQUENCY GENERATION SPECTROSCOPY SYSTEMS
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Oil-free Vacuum Pump / Compressor Today’s Instruments Co., Ltd.
9100 HPLC Trouble shooting.
Sensistor ISh2000 Hydrogen Leak detector
LIQUID CHROMATOGRAPHY
LIQUID CHROMATOGRAPHY
Varian 940-LC Analytical to Prep HPLC
FlexarTM: Advances in HPLC Sample Throughput
Agilent 1100 Series System Operating principles
Best Broken into four categories
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Introduction to the NGC Chromatographic System
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
Presentation transcript:

1 The YL9100S HPLC All your needs for semi-preparative applications

2 YL9100S HPLC Overview Superior Performance Greater Reliability Excellent Usability Serviceability and Easy Maintenance

3 YL9100S HPLC – Features 1 Higher performance solvent delivery pump - New designed carrier assembly and CAM - Improvement of precision Better UV/Vis detector with new optic design - For better light intensity and higher sensitivity New Detector – Photo Diode Array with excellent sensitivity Semi-prep flow cell is available Superior Performance

4 YL9100S HPLC – Features 2 Greater Reliability Improvement of System components - New designed main parts of Pump, Detectors and Column compartment with very robust materials Innovative manufacturing process - Three step quality control and assurance system

5 YL9100S HPLC – Features 3 Excellent Usability Intuitive, intelligent and powerful software - Easy control window for instruments of YL9100S HPLC - Harmonization Microsofts standards for accessing flies, reviewing data and reports, and other tasks - System Suitability Test with USP, EP and JP - Compliance with 21 CFR Part 11 - Diagnostics and Error detection Automation Perfectly of Analysis work - Startup, analysis operation, shut down, …, and to report generation

6 YL9100S HPLC – Features 4 Serviceability and Easy Maintenance Better long-life components - New designed the carrier, CAM, needle bearing, seals and belt (with polyurethane) for long-life time - New designed the Deuterium and Tungsten lamp guaranteed 2,000 hours - Semi-permanent peltier in the Column Compartment Easy Maintenance - Easy replacement and pre-alignment of lamps - Easy replacement of sample cell assembly - Diagnostics procedure by software

7 YL9100S HPLC – Modules List of Modules Degassing Module Pump Column Compartment UV/Vis Detector PDA Detector Refractive Index Detector Prep Autosampler Fraction Collector Chromatography Data System

8 YL9100S HPLC – Modules -HDVM YL9101S Vacuum Degasser - No fluctuationshorten warming up - No fluctuation, shorten warming up Number of channel : 2 CHs (option: 4 CHs) Maximum degassing range: 50ml/min High capacity of chamber: 62ml per channel Safety & maintenance : Vacuum Error detection Wide range of Line Voltage : VAC, ±10%, Wide range Line frequency : 50/60Hz, ±5% Power consumption : 50W YL9101S Vacuum Degasser will be available by June

9 YL9100S HPLC – Modules -HDVM Helium Degassing Valve Module Number of channel : 4 CHs Degassing type: Helium gas (This module is required a He gas cylinder) Wide range of Line Voltage : VAC Line frequency : 50/60Hz

10 YL9100S HPLC – Modules -VD Vacuum Degasser – Stand-alone type Number of channel : 2 CHs Maximum degassing range: 50ml/min Wide range of Line Voltage : VAC Line frequency : 50/60Hz Power consumption : 46W

11 YL9100S HPLC – Modules – Pump YL9110S Quaternary Pump YL9111S Binary Pump YL9112S Isocratic Pump New design of mechanical parts of pumps Compressibility Compensation technology Semi-automatic Prime/Purge Built-in Leak sensor Wide flow range by each check valve with two balls Ultra robust carrier, bearing, belt, etc For isolation and purification of preparative HPLC Flow rate: max. 50ml/min

12 YL9100S HPLC – Modules – BP YL9111S Binary Pump (Recommended for Semi-prep) A New Pump for higher throughput and reproducibility The best pump for High Pressure Gradient System Built-in Large capacity static mixer X2 Parallel dual-plunger Attractive price compared to QP Ideal pump for semi-prep application

13 YL9100S HPLC – Modules – QP/IP YL9110S Quaternary Pump Attached 4-way mixing valve to QP YL9112S Isocratic Pump Improved Isocratic Pump with parallel dual-plunger Easy upgraded from IP to QP

14 YL9100S HPLC – Modules -CC YL9130S Column Compartment - Powerful temperature control The best temperature precision: ±0.05°C Powerful Cooling is the standard: down to 4 °C Preheating available Semi-automatic injector/Switching valve: up to 1(option) Column capacity: 300mm – 2ea Leak sensor 40 steps programming Column OD: up to 28mm

15 YL9100S HPLC – Modules -UVD YL9120S UV/Vis Detector - Excellent sensitivity New designed Optic structure: Seya-Namioka New Blazed Holographic Concave Grating Excellent Data acquisition rate: up to 50 Hz Long-life D2 lamp, 2000 hours guarantee Advanced band width: 5.5 nm Excellent Sensitivity: <±0.5 x AU at 254nm Integrated cell and slit assembly Greater cooling of the lamps thermal environment Optimal cell volume and path length for semi-preparative purpose Leak sensor

16 YL9100S HPLC – Modules -UVD YL9120S UV/Vis Detector What is the Seya-Namioka monochromator - To attach New Blazed Holographic Concave Grating - Extremely low stray light - Highest light intensity - Reduced astigmatism - Very compact design and size - More serviceability - High performance beam splitter - New designed an integrated cell+slit assembly - Excellent band width, 5.5nm

17 YL9100S HPLC – Modules -PDA YL9160S PDA Detector Optimum wavelength resolution: 1,024 diodes Wide range from 190 to 950 nm Highest Sensitivity <±1.0 x AU at 254nm, 2 sec rise time <±2.0 x AU at 254nm, 1 sec rise time Fast data acquisition: 50 Hz Greatest drift level <2.0 x AU/h at 254nm, Baseline correction <1.0 x AU/h at 254nm - Highest Sensitivity

18 YL9100S HPLC – Modules -RID YL9170S RID - For universal detection RI Range : 1.00 ~ 1.75 RIU Noise : < ±1.0 x RIU Linear dynamic range : μRIU Flow rate range : 1 ~ 50.0 ml/min Cell pressure : 6 kg/cm 2 (84 psi)

19 YL9100S HPLC – Modules -AS YL9150 Autosampler – Prep Autosampler - Fully automated work Sample capacity: 24 vials(10ml for prep) Sample loop: 10ml Injection: partial loop RSD 1.0% for partial loopfill. Carry-over < 0.1% Option: Built-in Peltier cooling (4 o C ~ ambient –3 o C)

20 YL9100S HPLC – Modules -FC Fraction Collector – FC204/203B A stand-alone operation using time, drop or peak based collection Collect fractions by time, drop or peak with ease; manual collection is also available Simply set the time or number of drops, press START and walk away Drop counting: Up to 9,999 drops per fraction Maximum rate: 20 drops/sec HELP, YES, NO, 0-9 numeric hard keys/four soft keys 2-line, 24-character display on backlit LCD

21 YL9100S HPLC – Modules -CDS YL-Clarity CDS - Intelligent and Powerful Chromatography Data Station 1 Measuring Four Instruments up to 12 detectors. 2 Post-run Automatically displays, prints, exports and starts other programs

22 YL9100S HPLC – Modules -CDS 3 Column performance Method validation By USP, EP and JP 4 User accounts Sets up access rights and passwords 5 Audit trail Records selected events and operations into a special file. 6 Electronic signature Each chromatogram can be signed electronically. 7 Networked Solution Clarity files can be accessed from networked computers using Clarity Offline software. 8 Great Compatibility Window XP/2000. Window Me/98, and Window Vista (32bit) is available

23 YL9100S HPLC – Modules -CDS YL-Clarity CDS Perfectly compliance with 21CFR Part 11 GPC option available System Suitability Test option available(Method validation) PDA module option available: 3-D data analysis Software Validation option available: Software OQ S/W validation kit