Richard (Rick) Elwell Senior Operations and Safety Instructor and Consultant 419-961-8814

Slides:



Advertisements
Similar presentations
Subcontractor Electrical Safety & NFPA 70E
Advertisements

Basic safety rules and procedures for controlling hazardous energy
LIMITED APPROACH BOUNDARY
Murray State University
Electrical Safety.
Arc Flash: Electrical Safety in the Workplace CCIA Safety Committee SAFETY ROUNDTABLE April 10, 2012 sm 1.
Electrical Safety 29 CFR I. Background for the Trainer:
CONTROL OF HAZARDOUS ENERGY “LOCKOUT/TAGOUT” (LOTO)
Two-mode Safety and Battery System Service
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
1 Hazardous Energy Module 5. 2Objectives After this module you should be able to – identify the most common energy hazards – take the necessary steps.
San Bernard Electric Cooperative, Inc. Arc Flash Assessment.
Electrical Safety Adapted from Region IV - OSHA INSY
When working on or near electricity or electrical equipment you must be trained in & use Electrical Safety Related Work Practices NFPA.
Joe Cobb Crawford, P.E.,C.E.M. Crawford Engineering Services
ARC FLASH ANALYSIS.
Construction Training
Week 3 Electrical Circuits and Components. It’s a Radio!
Take 5 for Safety E. Lessard May 5, LANL Electrical Accident May 3, 2015  LOS ALAMOS, N.M. —Los Alamos National Laboratory workers were injured.
THE INTERNATIONAL SOCIETY OF FIRE SERVICE INSTRUCTORS Electronic INSTRUCT-O-GRAM Program Lockout / Tagout Policy.
INJURY PREVENTION ARC FLASH REGIONAL SAFETY MEETING.
Qualified Persons Working On Or Near Energized Equipment
Lockout - Tagout Control of Hazardous Energy CFR
Lockout Tag out Training2009. Control of Hazardous Energy Policy Personal locks & keys will be issued to employees by their Safety/Training Coordinator.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
EKAS Disconnect & Reconnect UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO1B Chris Hungerford Sunday,
High Voltage Electrical Safety
Electrical Safety Safety Training Series
Electrical Safety INSTRUCTOR’S NOTES:
Striving For Safety Excellence HunterDouglas Corporate Environmental, Safety, Risk Management LOTO – Authorized May 2011.
Lock-Out / Tag-Out Types of Energy Types of Energy Electrical Electrical Mechanical Mechanical Chemical Chemical Thermal Thermal Hydraulic Hydraulic.
© Evaluating Electrical Risk Factors Module 3.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Accommodation & Hospitality Services STAFF BRIEFING – No 16 Electrical Safety.
© Recognizing Electrical Risk Factors Module 2.
Electricity Compressed Air Steam Hydraulic Pressure Gas Lines etc.
Lockout - Tagout Control of Hazardous Energy OSHA Standard
SAFETYSAFETY. Overview ●Introduction to Safety ●Potential Electronic Mishaps ●Safe Work Practices.
Electrical Safety The following contains disturbing images and videos. Caution is advised.
MNM Fatal Electrical Accident Electrical Accident October 10, 2010 (Oklahoma) October 10, 2010 (Oklahoma) Granite Operation Granite Operation Contract.
Isolation Lock-Out Room Johns River Quarry Site Contact: Blake Ardrey, Quarry Manager, BCM, Johns River Quarry Phone:
Electrical Hazards Temporary Wiring and Lighting Systems.
Lockout/Tagout.
23,000 students trained since 1980 Electrical maintenance, troubleshooting and safety courses Safety programs, procedures and arc flash studies Leadership.
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
1 Electrical Safety This material was produced under grant number SH F-18 from the Occupational Safety and Health Administration, U.S. Department.
Copyright © 2012 American Safety Management Inc. Lockout Tagout.
Electrical Safety, Subpart K
The two types of electricity used in mining are: “AC” or alternating current and “DC” or direct current.
Lockout - Tagout Control of Hazardous Energy OSHA Standard
MNM Fatal Electrical Electrical November 18, 2013 (Kentucky) November 18, 2013 (Kentucky) Crushed Stone Mine Crushed Stone Mine Contract Electrician.
Electrical Work Practices City of Council Bluffs Presented by: SilverStone Group © 2012 Zywave, Inc. All rights reserved.
Chicago Area Facilities (CAF) Electrical Safety Program.
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Training of Airport Visual Aids Maintenance Personnel “Airport Operator” - Are you Meeting the Requirements? IESALC Denver 2015 Presented by Seward Ford.
What is an arc flash5 min. Video arc flash5 min. What causes an arc flash10 min. Video PPE15 min. PPE demo10 min Flash hazard15 min. ***Flash hazard analysis.
What is Arc Flash? Electrical arc flash and arc blasts release dangerous levels of heat energy, fire , molten materials, vaporized solids that can be inhaled,
Chapter 2 Safety. Chapter 2 Safety Objectives Understand the effects of electrical shock. Describe conditions likely to affect the severity of an electrical.
CENTERLINE® 2100 Motor Control Centers with ArcShield™
SAFE WORK INSTRUCTIONS
Personal Protective Equipment
SAFE WORK INSTRUCTIONS
Electrical Safety.
Murray State University
CENTERLINE® 2100 Motor Control Centers with ArcShield™
Electrical Hazards By Kory Hildebrand.
Presentation transcript:

Richard (Rick) Elwell Senior Operations and Safety Instructor and Consultant

Explain how training can save your company money. Discuss proper safety guidelines while placing a work area in an electrically safe condition and restoring equipment to operation, including PPE Selection and the Live-Dead-Live process. Explain safety concerns while troubleshooting and the proper safety techniques for live diagnostic testing: – Voltage measurements – Current Measurements – Insulation Testing Discuss Effective Troubleshooting Techniques using a Systematic Troubleshooting Approach

Electrical Safety training can save lives by: – Regularly reinforcing safe work practices – Providing employees with the information needed to keep them safe – Helping to reduce the risk of electrical-related accidents

Initial insurance costs for medical treatment and disability payments. Indirect costs for investigation, production loss, overtime, replacement of equipment impact to site from a loss of experienced employee(s).

Minimize the potential loss of critical equipment through operational and technical training by: – Creating a more efficient operator/technician with the ability to understand system response and quickly restore system redundancy and reliability – Reducing the potential for personnel (human) error which can lead to unexpected loss of up-time – Eliminating guessing (Easter Egging while troubleshooting) which often leads to replacement of the wrong component, resulting in reduced part replacement costs

Lock-Out/Tag-Out and check equipment de- energized whenever: – Ohmmeter readings are taken – Connecting clamp-on ammeter probes – Disconnecting or reconnecting wires – Replacing an electrical component – Performing visual inspections and/or adjustments inside electrical enclosures

… of stored energies. – During the LOTO process, safety discharge capacitors whenever present. Do not rely of bleeder resistor circuits. – If troubleshooting removable ACB-type circuit breakers, discharge closing springs.

The appropriate level of shock/Arc Flash PPE is required. – Use installed Arc Flash Labels – Or NFPA 70E PPE Selection Tables Energized work permits are not required for diagnostic testing and troubleshooting.

Do not reclose breaker or replace fuse(s) unless: – It is known to be caused by an overload condition – Circuit has been inspected for down-stream shorts.

Daily by user = once per shift, unless damage is expected Visual and Air Check

14 Pressure Waves 200 lbs/sq inch Copper Vapor: Solid to Vapor Expands by 67,000 times Molten Metal Extremely High Temps 15, ,000 °F mph Sound Waves 135+ decibels at 2ft Intense Light

Boundaries should be set around the work area to prevent: – unqualified workers from coming into contact with live parts. – Injury to those not in the appropriate level of PPE. – Protect the worker 15

Note: shock boundaries dependent on system voltage level. For <600V the Limited Approach Boundary is 3.5 ft. Equipment Prohibited Shock Boundary:Authorized Qualified Persons Only. PPE as if direct contact with live parts. Restricted Shock Boundary:Authorized Qualified Persons w/PPE Limited Shock Boundary:Authorized Qualified Persons w/PPE. Unqualified allowed only when conducting OJT and accompanied by a qualified person

Flash Protection Boundary (FPB) 1.2 Cal/cm2 Equipment Must wear appropriate PPE FPB based on available fault current and duration if an Arc Flash Analysis was performed. Values are listed on AF Label attached to equipment.

This incident energy exposure level shall be based on the working distance of the employees face and chest areas from a prospective arc source for the specific task to be performed. 480V MCC

Know meter functions and how it is protected. Know how to selected the right meter and its limitations: – Always use CAT 3 (or higher) meter. – A low-budget meter may kill you. Know how to use a device to verify the absence of voltage, including interpreting indications/readings. Inspect meters for safe use.

Conduct a Live-Dead-Live Test – Check meter on a know live source – Test the equipment (6-point check) Each Phase-to-phase Each Phase-to-Ground – Recheck meter on a know live source

7-Step Troubleshooting 1. Preparation 2. Observation 3. Defined problem area 4. Identify possible and probable causes 5. Test 6. Repair/replace and confirm 7. Follow-up

Questions?