Regional Manager for Munters

Slides:



Advertisements
Similar presentations
Refrigerators.
Advertisements

HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Basic Refrigeration Cycle
KE2 Evaporator Efficiency
Components of HVAC System
SANITARY DESIGN PRINCIPLES FOR FACILITIES. ZONES OF CONTROL.
Air Conditioning. Definition: Any treatment of the environment air within a building is air conditioning. Air cooling is any process that reduces air.
Refrigeration and Cooling Principles for Potato Storages
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Moisture Assessment WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Jim Chmielewski – HVAC Sales Manager Emerson Control Techniques
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Cold-Plus™ Refrigerant Enhancer
COMMERCIAL REFRIGERATION
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Hawke’s Bay Refrigeration
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Refrigeration Basics 101.
Refrigeration and Cooling Principles for Potato Storages Roger Brook Professor and Extension Engineer Agricultural Engineering Department Michigan State.
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Advanced Humidity Control. Energy Efficient Desiccant Based Dehumidification New class of desiccants that regenerate at lower temperatures Now able to.
Wicked Weather WHAT YOU LEARN How we measure humidity. How fog, frost, and dew form. Why and how clouds form. Adiabatic Cooling and Warming. How clouds.
Refrigeration Systems
Best practice small scale commercial refrigeration, optimisation strategies and simple maintenance Michael Bellstedt, Minus40 Pty Ltd.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Moisture Assessment WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
SECTION 7 AIR CONDITIONING (COOLING) UNIT 35 COMFORT AND PSYCHROMETRICS.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Atmospheric Humidity.
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
. Level 3 Air Conditioning Inspections for Buildings
Lecture 6 Drying.
Refrigeration & air conditioning
5.2.7 Evaporative Coolant System
Doug Jefferson, Business Development Engineer
Thermal mass dynamics 1.00 Heat absorption
What is Desuperheater Water heater and its Applications?
Air-Row Fans Minimize Freezer Door Sweating
SOMEWHERE OVER THE RAINBOW
Munters DH Systems for Hospital Applications
Dry Kilns for Food.
How would you describe humidity in your own words?
Munters DOAS, Chilled Beams and VRV
Dehumidification Systems for Food Applications
Munters DOAS and Chilled Beams
April 6th, 2010 Munters DH Systems for Bulk Storage / Pneumatic Conveying Presented by: Andrew Cook Segment Manager.
Brian Wallingford, Applications Engineer
Cheryl Hughes Regional Sales Manager October 6, 2015
Jeff Siemasko, VP Sales & Marketing - North America
Water in the Atmosphere
Munters DH Systems for Freezer Applications Presented by: Mike Sadosky
Atmospheric Humidity.
Water in the Atmosphere
Humidity.
Humidity.
Humidity.
WATER IN THE ATMOSPHERE
FBE03: Building Construction & Science
Water in the Atmosphere
Essential Question: How does the water cycle explain various atmospheric conditions on the Earth? Standard: S6E3b. Relate various atmospheric conditions.
Lecture Objectives Review what we learned about Eclectic Energy Production Learn about Thermal Comfort Introduce Psychrometric Chart.
Humidity.
Lecture Objectives Learn about Psychrometric Chart Quantities
Atmospheric Moisture: Relative Humidity and Dew Point
Water in the Atmosphere
How Refrigerators and Freezers Work
Moisture in the Atmosphere
Pneumatic System Conditioning
Presentation transcript:

Regional Manager for Munters Lennart Bosman Benefits of Humidity Control in Low Temp Spaces 38 years in the industry primarily with the food, pharmaceutical and archival markets to reduce and control humidity within production and storage facilities. Provides engineering and sales support to solve problems or implement strategies to improve or streamline facility operations. Regional Manager for Munters Placeholder SLIDE Dealing primarily with the food, pharmaceutical and archival markets to reduce and control humidity within production and storage facilities

Lets start by defining low temperature spaces, separating them into three zones: Cool ~ 60 F and up (30 to 60%RH, 29 to 46 dew point) Labs, operating rooms, surgical suites Cold ~ 33 F to 59 F Storage, loading docks, processing rooms Frozen – below 32 F Long term storage

Cool, Cold or frozen rooms? Cool/Cold rooms Loading docks Meat processing rooms Meal assembly rooms Laboratories Lasik and other surgery suites In all the above if the dew point delivered is above 40 F, the use of refrigeration is most likely the best solution. Frozen rooms, below 32F… Process Freezers Hardening tunnels Cold storage In all frozen rooms or if the dew point desired is below 40F, you should use desiccant.

Psychrometric-terms... Refrigeration viability only above the line Grains/lb Refrigeration viability only above the line

Methods of dehumidification... Cooling based (condensing) DX refrigeration, sub-cool and reheat Chilled brine Ammonia Co2 Desiccant based (adsorbtion) Stacked tower Liquid spray systems Wheel systems

In either case, cold rooms or frozen rooms, first, determine the load... The humidity loads are; Permeation Infiltration Internally created Then size the dehumidifier to match the project needs and loads

Munters company presentation Design conditions May 4, 2019 Munters company presentation

Munters company presentation Permeation May 4, 2019 Munters company presentation

Munters company presentation People load May 4, 2019 Munters company presentation

Munters company presentation Pass through May 4, 2019 Munters company presentation

Munters company presentation Air lock or vestibule May 4, 2019 Munters company presentation

Munters company presentation Cracks May 4, 2019 Munters company presentation

Munters company presentation Total Internal load May 4, 2019 Munters company presentation

So, how much dryer do we need? This is the difference between what we want in the space and what the dryer can supply May 4, 2019 Munters company presentation

For cool rooms we would use Cooling-Based Dehumidification

Reducing humidity or Eliminating Ice To reduce or eliminate ice accumulation the moisture level (dew point) must be low enough to prevent condensation on cold surfaces, so dehumidification is required. To understand the limitations of condensation control in low temperature spaces one must first recognize the differences between the two methods of dehumidification – cooling versus desiccant. Both technologies remove moisture from air. The primary difference is the dew point of the air that each can effectively deliver.

Psychrometrics of Cooling-Based Dehumidification Air is circulated over a cold coil and cooled to saturation Further cooling condenses moisture on coil fins Dew point reduction is limited by minimum practical coil temperatures (freezing) Subfreezing areas that utilize this method must deal with ice build-up on evaporators, walls, floors, ceilings, door frames, etc. Regularly scheduled defrosts are needed and have become the standard operating procedure. NOTE: Primary objective is temperature control, dehumidification is a byproduct.

Typical Cooling Coil Performance Cold Air Discharge From Coil At 50°fdb, 95% Relative Humidity 51 gr./lb. = 49oF dewpoint Humid Air Entering Coil At 75°f, 70% Relative Humidity 92 gr./lb. = 65oF dewpoint Cooling Coil (CW or DX) Moisture Condensed Out By Lowering Air Temperature (92-51 = 41 gr./lb. in this example)

Typical Coil Performance Below Freezing FROST AND ICE BUILD UP ON COIL CAUSED FROM SURFACE TEMPERATURES BELOW 32°F FROST FOG HUMID AIR ENTERING COIL AT 40°FDB, 70% RELATIVE HUMIDITY COLD AIR DISCHARGE FROM COIL AT 25°FDB, 95% RELATIVE HUMIDITY MOISTURE CONDENSING LIMITED BY COIL TEMPERATURE FREEZING OCCURS @ 32°FDB

Psychrometric Plot Typical Cold Storage PSYCHROMETRIC PLOT OF CONDITIONS IN PROCESS FREEZER & COLD STORAGE APPLICATIONS WITHOUT DESICCANT DH 40 140 35 120 30 PACKAGING AREA AT 45-50 F 100 Enthalpy - Btu per Pound of Dry Air 25 80 Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) 20 Fog 60 15 Frost 40 Ice 10 20 -10 -10 10 20 30 40 50 60 70 80 90 100 110 Dry Bulb Temperature °F

Desiccant-Based Dehumidification

Psychrometric Plot Cold Storage with desiccant DH PSYCHROMETRIC PLOT OF DESIGN CONDITIONS IN PROCESS FREEZER & COLD STORAGE APPLICATIONS WITH DESICCANT DH 40 140 35 120 30 100 Enthalpy - Btu per Pound of Dry Air 25 80 20 Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) 60 15 40 10 20 -10 -10 10 20 30 40 50 60 70 80 90 100 110 Dry Bulb Temperature °F DEHUMIDIFY TO 5.5 GR/LB ( -20 F DEW POINT)

Desiccant Dehumidification: Wheel carries desiccant Desiccant wheel removes moisture from process air Wheel rotates to reactivation section. Heated air drives moisture away Supply (dry) air has dew point below surface temperatures Dry air acts as a sponge, preventing moisture from condensing on surfaces. Defrost cycles extended considerably, evaporators operate efficiently. NOTE: Primary objective is dehumidification

Working in cold storage… is not always easy

Applications in cold environments… Loading docks - large infiltration loads from truck doors Cold storage freezers - moisture from loading dock and process area Spiral freezers – moisture from product and the environment Plate freezers – moisture from environment Process freezers – moisture from product and environment Meat processing - moisture from various sources causing overhead condensation

Control the Dew Point Reduce temperature - moisture will condense on machinery, walls or product. Relative Humidity (RH) compares how much moisture is in the air and how much it can hold 100% RH is saturated air Over 60% RH results in condensation and then mould growth Dehumidification prevents condensation and reduces mould growth

Effects of Door Openings on Freezer Fog and condensation Ice on Floors, Walls, Doors & Evaporators Extensive cleaning time Food warms (food quality / safety) Refrigeration plant over worked Increased energy consumption Increased defrosts (inefficient, increased downtime) Ice in room (worker safety, reduced operator speed) Contamination through door Iced evaporator (reduced air flow, increased maintenance)

The warehouse culprit.. Many cold stores are not equipped with an airlock, often using plastic strip curtains to reduce the amount of moisture introduced when the door is opened. This approach does not provide a complete vapor barrier. Moisture still infiltrates into the cold store, ice builds up on evaporators, overhead structures, door mechanisms, floor, etc.

Freezer Air Lock / Loading Dock In addition to Ice, fog & frost this causes: Blinding strip curtains Poor visibility Lost cooling capacity Extended loading times Fork truck and structural damage High maintenance cost of doors etc. Need for mechanical de-icing

risk of accidents caused by slippery floors Problem: SAFETY Unsafe environment - risk of accidents caused by slippery floors Can be very costly $$$

In some cases the problem has to be attacked from inside the freezer, there are units on the market that can do this, delivering -40 to -57 F dew point

Limited Access Cold Storage Stand alone unit designed to run continuously, providing ice removal 24 hours per day. Cost effective solution for limited access areas: cold storage doors open < 10 minute per hour facility doesn’t operate 24 hours per day. Gives IceDry® chance to remove moisture that infiltrated during the day. If door activity varies or is expected to increase in future then include an air curtain in design to improve dry air distribution over the cold door.

Stand-Alone Solution

Combining desiccant with an Air Curtain can be the best response Cold Store -20°F Dry Air Dew Point @ -55°F Munters IceDry ®

KLM Catering Services Before After

Freezer / Loading Dock One example LOADING DOCK FREEZER LOADING DOCK Frost & Ice build up TEMP = -13oF (25oC) TEMP + 41oF (5oC) 85% RH 32 gr./lb (4.5 g/kg.) Warm air inflow Moisture leakage Fog Cold air outflow Wet floor Iced floor

With Dehumidifier Installed Desiccant dehumidifier keeps the Loading Dock dry, reducing the moisture load to the Freezer Moist air from Loading Dock Dehumidifier Dry air Frost free Cold Storage Area Moisture infiltration Dry floors Dry floors

Dehumidification & Defrosts Defrosting is an expensive business One open door (8’ x 10’) can allow 1 gallon of water to enter a cold Freezer every minute When ice settles on a cooler, the refrigeration system has to cool through a layer of insulating ice Defrosts can represent 15% of energy consumption in Freezers

Benefits of Dehumidification Floors/doors kept dry and ice-free Speed up loading and unloading Fork trucks operate at normal speed Reduced occupational injuries from slips, falls and pallet mover accidents No ice on strip curtains or fog around door, visibility is improved Trouble-free pulldown after washdown Coils run more efficiently and run longer between defrosts One customer saved $20K in 8 mos.

Frost and Ice removal Advantages Reduced Labor Costs: No more chipping away ice by hand. Improved Worker Safety: Reduction of slippery floors and no ice falling from overhead surfaces. Reduce costly worker injuries Elimination of fog improves visibility. Increased Productivity: Loading time is reduced when fork truck operators can move efficiently across ice-free floors and their visibility is high. Lower Maintenance Costs: Reduced electrical and mechanical failures = less downtime. Switches, motors, lights, and evaporators (fins, tubes) do not suffer from ice build-up. Fewer floor repairs due to heaving and cracks. Before After

Before After

Evaporators Before & After

15 days later

Roof Void Condensation Fire detection impeded Moisture leaching through into insulation - freezes Smallest perforations can penetrate and increase weight Lose insulation value Reduced safe working load for panels Panels bowing and collapsing

Dehumidification for Process Freezing

Frozen Baguettes Moisture Sources: Product releases moisture Infiltration of moist production air Washdown water Benefits of Dehumidification: Increase production capacity Less stoppages due to defrosts and cleaning Constant product quality Reduced cleaning labor Reduced high investments to increase freezer capacity Fast payback Energy savings through quicker cooling after washdown

In process freezer dehumidification increases operation between defrost cycles

Ice Cream Plant Problem: Electronic Sensors In Carousel Freezer Coating With Ice Requires Manual Cleaning Every Two Hours Freezer Maintained at -35°F Solution: Dehumidify Ante-Room Surrounding The Carousel Freezer With Dry Air Force All Air Being Drawn Into The Freezer To Be Dehumidified.

Ice Cream Plant Before Installation of Dehumidifier

Ice Cream Plant After Installation of Dehumidifier

Summary Desiccant dehumidification reduces or eliminates moisture problem in PRW’s and food processing areas Evaluate benefits of controlling 3 phases of moisture: Vapor – fog, mist. Eliminating fog will improve visibility, increase worker safety, and raise productivity. Liquid – water, condensation. Eliminating condensation will maintain dry floors (improve worker safety and productivity), dry packaging materials (enhance product quality and shelf life), and prevent product adulteration (improve food safety and reduce scrap). Dry coils will also pay efficiency dividends. Solid – ice. Reducing / eliminating ice will extend time between defrost cycles (saving energy and increasing productivity), reduce maintenance costs, and improve worker safety.

Questions? Any questions? Thank you!