Model Reversion : A Client : Slider qty : 1 Model : Latte 2nd Lifter qty : Part name : GUIDE-2NDINPUTTRAYRIGHT-MP Gate type : Side gate Part no.. : Cavities : 2 DFM by : Yao Lichun 2/3 Plate :
DFM follow-up issue. Integral Corrective Action List ICAL ICAL 1 - Date of opening (all dates in 2005) 2 - Date of beginning of action 3.- Date foreseen for validation DFM follow-up issue. Integral Corrective Action List 4 . Date of validation( closing) Page Open points Solutions / Action Who 1 2 3 4 P.3 Gate (mold flow) Waiting for confirmation. 07/09 P.4 Parting line P.5 Slider P.6 Suggestion Waiting for confirmation P.7 P.8 Draft angle P.9 P.10 P.11 Texture
Gate (mold flow) Side gate
The red line is part line Parting line The red line is part line
Slider Slider
Suggestion These poles too thick, it will cause sink mark. The red ribs are too thick, it will cause sink mark, suggest cut plastic and keep 1.4mm at ribs’ bottom, 1.2mm at ribs’ top.
Suggestion Thin steel here. 1.0
Draft angle There are will be steps. We suggestion cut the red area plastics 1 degree for cavity and cut the blue shade plastics 0.5 degree for core
Add 5 degree on all red surfaces (reduce plastic). Draft angle Add 5 degree on all red surfaces (reduce plastic).
Draft angle 1. For the other ribs, side surface in the cavity & slider, we will make a draft angle less than 2 degree (reduce plastic). 2. For the other ribs, side surface in the core, we will make a draft angle less than 1 degree (reduce plastic).
Texture Which area need texture? Please make enough draft angle for the texture.