Laboratory Methods Workshop Total Sulfur Dioxide

Slides:



Advertisements
Similar presentations
Determination of Vitamin C Concentration by Titration
Advertisements

Acid-Base Stoichiometry
Volumetric Analysis.
Analysis & Stoichiometry Adv Higher Unit 2 Topic 1 Gordon Watson Chemistry Department, Kelso High School.
Solution Stoichiometry
Acids and Bases - Titration
Titrimetric procedure and Acid and Base Titrations Ch 20
SCH3U Solutions and Solubility
Sulfur Dioxide Measurement and Management
Determination of bicarbonate in blood
TITRATION This involves removing small samples from the reaction mixture at different times and then titrating the sample to determine the concentration.
Standardisation of Sodium Hydroxide solution
Stoichiometry Calculations based on chemical reactions.
Vitamin C tablets vs. Citrus fruit juice
Section 8.4 – pg  Experimental designs discussed so far have been QUALitative (flame test, solution colour, litmus test, conductivity, solubility)
TITRATION Andy Park. What is Titration? A method of quantitative chemical analysis used to calculate concentration A known concentration and volume of.
Volumetric analysis 4th lecture.
Acid Base Titrations Chemistry 12◊ Chapter 14. Titration: A titration is a technique for finding an unknown concentration of one chemical from the known.
Acid-Base Reactions and Titration Curves. Neutralization Reactions Neutralization reactions occur when a base is added to an acid to neutralize the acid’s.
Volumetric Analysis – Titrations Volumetric Analysis a process of analysis accomplished by adding together particular volumes of 2 solutions the objective.
Phase Two Titration Year 10 EEI by Mr H Graham Volumetric analysis is; A type of chemical analysis which depends on the accurate measurement of solution.
Titration Analysis.
 If a VOLUME is mentioned, and the problem involves molarity DO NOT assume that 22.4L should be used. STP is only used when it says STP in the question.
Chapter 15. Section 1  The Ionization Constant of Water (K W )  Water self-ionizes to a small extent to form H 3 O + and OH -  The concentrations.
Stoichiometry: Quantitative Information About Chemical Reactions Chapter 4.
Dr.Shuchita Agrawal BTIRT Sironja,Sagar(MP)
Review Chemical Reactions Types of Reactions Controlling Reactions Rates of Reactions Acids and Bases pH level.
Equilibrium. Chemical equilibrium is the state where the concentration of all reactants and products remain constant with time. At equilibrium, the rate.
Environmental Chemistry Lesson # 2
Chemical change or Physical change ?????.
Mini test – write the formulae for
HC CHEMISTRY HC CHEMISTRY CHEMISTRY IN SOCIETY (E) CHEMICAL ANALYSIS.
Acids and Bases.
Titration burette clamp ring stand burette erlenmeyer flask (buret)
Calculations in Chemistry
Assay of aspirin The main methods used in quantitative determination of ASA either in its pharmaceutical preparations or powdered pure form are: 1- Spectrophotometric.
Titration Volumetric analysis
What is an acid? Here are some facts about acids.
Acid and Bases. pH.
Introduction to Solutions
Volumetric Analysis.
What type of reaction is this?
Chemical Equations and Reactions
Changes in Acid-Base Reaction Systems
Acids and Bases Chapter 32.
Neutralization.
What type of reaction is this?
Reactions in Aqueous Solutions II: Calculations
Electrolysis AQA Chemical Changes 2 Reactions of acids
Concentration.
COMPOUNDS AND MIXTURES
Determination of Cu in Brass
Chapter 11 Acid-Base Titrations
Titration burette clamp ring stand burette erlenmeyer flask (buret)
Conservation of Mass Noadswood Science, 2016.
Titrations & Ionization Constants
EXP. NO. 6 Acid Base Titration
Titrations & Ionization Constants
Laboratory Methods Workshop Sugar
Laboratory Methods Workshop Alcohol
WATER AND HYDROGEN.
Chemical Equations and Reactions
Experiment Questions Alcohol from Yeast.
Calculations in Chemistry
Reactions in Aqueous Solutions II: Calculations
Titration Precautions
Week 6 – Acids and Alkalis
Best Practice Measurement of Total Sulfur Dioxide
Sugar Free Extract and the Impact of Sugar Analysis
Presentation transcript:

Laboratory Methods Workshop Total Sulfur Dioxide Dr Eric Wilkes The Australian Wine Research Institute

1. Chemical entity Sulfur dioxide (SO2) is both added to grapes and wine and also produced by yeasts during fermentation. It has a dual role as an antimicrobial and antioxidant in finished wines. SO2 once added to wine exist in a number of equilibrium forms.

1. Chemical entity In solution it exists in 3 main forms in equilibrium SO2 Molecular + H20 HSO3- + H+ Bisulfite SO32- + 2H+ sulfite 92~99% 80 60 40 20 2 4 6 10 8 At wine pH the bisulfite form dominates 92~99% pH

1. Chemical entity These forms also interact with other wine components. The bisulfite anion reacts with carbonyls, particularly acetaldehyde We talk about free (unbound SO2 and HCO3-) bound (carbonyl and other bound species) total (free and bound added) free bound SO2 HSO3- SO32- SO2 bound to phenolics, colour, sugars SO2 bound to acetaldehyde SO2 HSO3- SO32- SO2 bound to acetaldehyde, phenolics, colour, sugars total

2. Units of measurement The main measurement of interest in most regulatory systems is total SO2 (TSO2). This includes the summation of all forms of SO2 present including bound and unbound forms. In most economies which regulate TSO2 it is expressed in terms of mg/L of the wine.

3. Limits of measurement APEC 2015 Ring Test Results White Red Importantly, standard deviations of 19 and 36 for whites and red respectively

3. Limits of measurement 2015 Interwinery Results Round 1 Round 2 Ave SD 136 147 6.3 138 145 6.6 137 143 5.0 134 63 4.0 140 59 4.3 56

4. Methodologies Four common methods aeration / oxidation Ripper flow analysis enzymatic There are others but they are not common enough to cover here

4. Methodologies Aeration / oxidation (also known as Monier/Williams or Rankine) is generally considered the reference method and is least prone to interference by wine components for TSO2. Ripper (or iodic titration) is also commonly used but suffers from phenolic interference. The other methods while well developed are not as commonly used and generally referenced against the first two methods.

Practical application (A/O) Basic Principles Acidify sample to drive free to molecular form. Pass a stream of air through the heated (not boiled) liquid to carry the SO2 up through a condenser (more about that later) into a solution of hydrogen peroxide and indicator. H2O2 + SO2  H2SO4 Titrate the acid generated with sodium hydroxide. Calculate the original amount of SO2 The condenser prevents volatile acids making their way over to the H2O2

Practical application (A/O) Titration endpoint ✓ Titration with 0.01M NaOH

Practical application (Ripper) Basic principles A 20 mL sample is placed in a flask with 25 mL of NaOH (1M) and left to equilbrate (10 Minutes). Vitex indicator added (detect unreacted iodine). 10 mL of 25% v/v H2SO4 is used to acidify sample. NaHCO3 is added to form a CO2 blanket to stop O2 interference. The sample is titrated with a standard iodine solution until a blue colour. HSO3- +I3- + H2O  SO42- + 3H+ + 3I- Calculate SO2 based on iodine used.

Common issues / interferents Aeration / Oxidation No significant interferents, although very high volatile acidity can reduce accuracy. Incorrect carrier gas or heating can lead to both high and low results dependent on situation.

Common issues / interferents Ripper Interference by phenolics, sugars, aldehydes and other reducing substances. Cannot be used in wines containing ascorbic or erythorbic as these react quantitatively with the iodine. Endpoint is difficult in red wine. Method is generally considered less accurate than AO due to interferents in wine.

Quality control The first and every 10th sample should be a wine of known TSO2. Duplicate are advisable but should not replace a control wine of matched matrix. A standard 100 mg/L TSO2 solution should be made freshly and run at least weekly. Recovery should be better than +/- 5% A 1 g/L acetic acid solution should be run at least once a week with no more than 1 mg/L of calculated TSO2 apparent (not applicable to Ripper).

Precautions (AO) Regularly check gas flow rates. Initial sample temperature should be 20∘C +/-5. Samples should not have H3PO4 added until immediately before aspiration. Samples should not be left open for any extended period of time. Peroxide solution should be made up regularly.

Troubleshooting (AO) Peroxide solutions go off in heat and light. Poor quality water gives poor indicator colour and degrades peroxide Putting the indicator in your peroxide supply will make it deteriorate more quickly NaOH solutions do change with time (re-standardise) Temperature is important. Excessive vacuum grease absorbs SO2. Residue detergent can react with SO2. Positive pressure systems can leak but are easy to balance gas flows. Vacuum systems don’t leak, but are much harder to balance gas flow.

Troubleshooting (AO) Air bubbles in burettes (particular hidden ones in digital burettes) leads to titration errors High gas rates and boiling solutions can carry over droplets of wine and VA giving false highs. Low gas flow leads to low results. Adding orthophosphoric acid too soon before aspirating can lead to low results. Blowing through the bubbler tube can dissolve carbonic acid leading to end-point changes. Target an endpoint that is repeatable. Dripping wine and juice can stuff up Bunsen's.