Changes in serum albumin concentration and volume expanding effects following a bolus of albumin 20% in septic patients Margarson M.P. , Soni N.C. British Journal of Anaesthesia Volume 92, Issue 6, Pages 821-826 (June 2004) DOI: 10.1093/bja/aeh111 Copyright © 2004 British Journal of Anaesthesia Terms and Conditions
Fig 1 Twenty‐four h albumin concentrations after albumin 20%, 200 ml bolus in the first 44 septic patients studied. Data are mean and sd. British Journal of Anaesthesia 2004 92, 821-826DOI: (10.1093/bja/aeh111) Copyright © 2004 British Journal of Anaesthesia Terms and Conditions
Fig 2 Haematocrit values after albumin 20%, 200 ml in 26 non‐septic controls. The interrupted line indicates the calculated change in haematocrit resulting from haemodilution alone (see Appendix). Data are mean and sd. British Journal of Anaesthesia 2004 92, 821-826DOI: (10.1093/bja/aeh111) Copyright © 2004 British Journal of Anaesthesia Terms and Conditions
Fig 3 Plasma albumin concentration after albumin 20%, 200 ml in 26 non‐septic controls. Data are mean and sd. British Journal of Anaesthesia 2004 92, 821-826DOI: (10.1093/bja/aeh111) Copyright © 2004 British Journal of Anaesthesia Terms and Conditions
Fig 4 Haematocrit values after albumin 20%, 200 ml in 66 septic patients. The interrupted line indicates the calculated change in haematocrit resulting from haemodilution alone (see Appendix). Data are mean and sd. British Journal of Anaesthesia 2004 92, 821-826DOI: (10.1093/bja/aeh111) Copyright © 2004 British Journal of Anaesthesia Terms and Conditions
Fig 5 Plasma albumin concentration after albumin 20%, 200 ml in 66 patients. Data are mean and sd. British Journal of Anaesthesia 2004 92, 821-826DOI: (10.1093/bja/aeh111) Copyright © 2004 British Journal of Anaesthesia Terms and Conditions
Fig 6 Changes in the albumin increment (% of initial increase) in 26 controls and 66 septic patients after albumin 20%, 200 ml. British Journal of Anaesthesia 2004 92, 821-826DOI: (10.1093/bja/aeh111) Copyright © 2004 British Journal of Anaesthesia Terms and Conditions
Fig A1 Equations calculating the haematocrit expected at 1 min following a 200 ml bolus of fluid. British Journal of Anaesthesia 2004 92, 821-826DOI: (10.1093/bja/aeh111) Copyright © 2004 British Journal of Anaesthesia Terms and Conditions