Beam Interlocks for Detectors and Movable Devices

Slides:



Advertisements
Similar presentations
Jan Uythoven, AB/BTLHCCWG, 3 May 2006 Page GeV Commissioning Machine Protection Needs to be commissioned to: Prevent damage with the used, higher.
Advertisements

Beam commissioning strategy Global machine checkout Essential 450 GeV commissioning System/beam commissioning Machine protection commissioning.
Day ● 09:00-14:00: Collimation setup 3.5 TeV – Slowed down by losses induced by tune hump. – 48 collimators set up. – Beam dumped by ATLAS during.
CERN Machine Protection – A Future Safety System? Introduction 1 SMP = Safe Machine Parameters System which receives accelerator.
Technical review on UPS power distribution of the LHC Beam Dumping System (LBDS) Anastasia PATSOULI TE-ABT-EC Proposals for LBDS Powering Improvement 1.
The Architecture, Design and Realisation of the LHC Beam Interlock System Machine Protection Review – 12 th April 2005.
Overview of Machine Protection for the LHC
January 2006Beam dump and injection inhibits / J.Wenninger1 Beam Dump and Injection Inhibits J. Wenninger AB-OP & D. Macina TS-LEA LHC experiments signals.
Distribution of machine parameters over GMT in the PS, SPS and future machines J. Serrano, AB-CO-HT TC 6 December 2006.
Daniela Macina (CERN) Workshop on Experimental Conditions and Beam Induced Detector Backgrounds, CERN 3-4 April 2008 Experiments protection from beam failures.
Status of Data Exchange Implementation in ALICE David Evans LEADE 26 th March 2007.
V. Kain, G.H. Hemelsoet AB/OP1Nov 08, 2007 LHC Injection System V.Kain, G.H. Hemelsoet, AB/OP Input from: E. Carlier, B. Goddard, J. Wenninger What do.
Experimental equipment interacting with beam operation D. Macina TS/LEA Many thanks to my colleagues both from the experiments and the machine for their.
BCT for protection LHC Machine Protection Review April 2005 David Belohrad, AB-BDI-PI
Post Mortem Collimators and Movable Objects Michel Jonker Post Mortem Workshop Cern, 16 & 17 January 2007.
1 Beam Plans for Accelerator Systems: The Machine Protection System Jan Uythoven On behalf of the MPWG and the MPS Commissioning WG Special thanks to R.Schmidt,
1 Interlock logic for LHC injection: intensity limitations Jörg Wenninger AB-OP-SPS Outcome of the join Machine-Experiments Workshop on Machine Protection.
V. Kain AB/OP1Sep 12, 2007 Summary of Discussion on Injection Protection Issues Injection Protection Issues – meeting 22 nd of June V. Kain, A. McPherson,
BP & RS: BIS & SLP for AB/CO Review, 23 h Sept Realisation of the interlocking between SPS, LHC and CNGS and open issues Beam Interlock Systems.
1 CC & MP - CC10 - CERN Crab LHC J. Wenninger CERN Beams Department for the LHC Machine Protection Panel.
Real time performance estimates of the LHC BPM and BLM system SL/BI.
Beam Interlock System MPP Internal ReviewB. Puccio17-18 th June 2010.
1 Commissioning and Early Operation – View from Machine Protection Jan Uythoven (AB/BT) Thanks to the members of the MPWG.
B. Todd et al. 19 th August 2009 The Beam Interlock System Thanks to: Machine Protection Panel, R. Schmidt, B. Puccio, M. Zerlauth and many more… 0v2.
Thursday 20 th April 01:53 RCBV17.R7B2 tripped as happened few days ago: SIS intercepted. 05:54 Stable beams, 1380b, still RF problems B1, abort gap cleaning.
LHC machine protection close-out 1 Close-out. LHC machine protection close-out 2 Introduction The problem is obvious: –Magnetic field increase only a.
BIS main electronic modules - Oriented Linac4 - Stéphane Gabourin TE/MPE-EP Workshop on Beam Interlock Systems Jan 2015.
The LHCb Online Framework for Global Operational Control and Experiment Protection F. Alessio, R. Jacobsson, CERN, Switzerland S. Schleich, TU Dortmund,
The TV Beam Observation system - BTV
DRY RUNS 2015 Status and program of the Dry Runs in 2015
2007 IEEE Nuclear Science Symposium (NSS)
Overview of the Beam Interlock System
About Interlocks, Timing Systems and how to send SPS beams to the LHC
Overview of CERN BIS and Communication Hardware
LINAC4 50 MeV phase BIS STATUS
SPS extraction, transfer lines, injection
LV Safe Powering from UPS to Clients
M.Jonker CTC MPO-WG status
Safe mode transmission
Commissioning and Testing the LHC Beam Interlock System
0v1.
Safe Injection into the LHC V.Kain AB/CO
Saturday 09:40 Stable beams #1369 (56 bunch scheme)
Safe Injection into the LHC V.Kain AB/CO
Initial Experience with the Machine Protection System for LHC
MPSC Procedures An update
Machine Protection Xu Hongliang.
LHCCWG Meeting R. Alemany, M. Lamont, S. Page
Interlocking of CNGS (and other high intensity beams) at the SPS
Dry Run 0 Week 13: BI test of...everything circulating beam: all fixed displays and BI applications OP directories for 2009, concentrators running Need.
Beam Dump and Injection Inhibits
Wire almost entirely through beam before BLM triggers dump
450 GeV Initial Commissioning with Pilot Beam - Beam Instrumentation
Protection against accidental beam loss at the LHC
LHC dry-runs (BE-BI view)
Machine Protection System Commissioning plans
Wednesday 10:00 test of the un-squeeze to 90 m at 4 TeV.
1v1.
Commissioning of the Beam Conditions Monitor of the LHCb Experiment at CERN Ch. Ilgner, October 23, 2008 on behalf of the LHCb BCM group at TU Dortmund:
BCM-BIS Interface Szandra Kövecses
Interlocking of LHC experiments
Monday 8th December Morning used for RF work (IP z, injection), damper noise checks. Stable beams period with LHCb spectrometer OFF – lost beam after.
Machine protection and closed orbit
CNGS Primary Beam Results 2011
The LHC Beam Interlock System
Interlocking strategy
Wednesday 23/2 Thanks CRYO!!!.
Close-out.
HI2011 Commissioning Status
SPS Injection BIS - Draft requirements
Presentation transcript:

Beam Interlocks for Detectors and Movable Devices J. Wenninger AB-OP-SPS for the LHC Machine Protection WG Reminder on the LHC Interlock System (LEADE 18.10.2004). Safe LHC Paramters & their distribution. Preliminary ideas on Interlocks for detectors & movable devices. Technical drawings : courtesy of B. Puccio (AB-CO) 31.01.2005 J. Wenninger / LEADE

Beam Interlock System : aims and objectives The primary aim of the LHC beam interlock system is to provide a failsafe & high reliability link between users requesting a beam abort and the beam dumping system. In addition it is linked to the SPS extraction system to permit/inhibit beam injection. Two roles: 1) Allow injection when ALL user systems are ready for beam. 2) Transmit any beam dump request from user systems to the Beam Dumping system. Additional objectives: Protect the beam Faulty trigger signals should be avoided. Provide post-mortem information For multiple alarms: identify the initial failure & given time sequence. 31.01.2005 J. Wenninger / LEADE

Principle of the Beam Interlock System BEAM1_PERMIT BEAM_PERMIT STATUS SIGNALS BEAM2_PERMIT to User Systems SPS Extraction System for beam 1 for beam 2 Beam Dumping System USER_PERMIT SIGNALS UNMASKABLE INPUTS MASKABLE INPUTS Mask Settings Safe Beam Flag PM event Trigger Timing System LHC protection systems User System #2 User System #9 User System #16 User System #1 User System #8 User System #10 LHC Injection System 31.01.2005 J. Wenninger / LEADE

Distributed architecture Clients are connected to the BIC modules 31.01.2005 J. Wenninger / LEADE

Beam Permit status signal The BEAM_PERMIT carried by the Intk loop can be: TRUE (beam operation is permitted) Injection of beam is allowed. Beam operation continues. FALSE (beam operation is NOT permitted) Beam injection and SPS extraction are blocked. If beam is circulating and the BEAM_PERMIT changes from TRUE to FALSE, then the beam will be extracted to the dump. There is one BEAM_PERMIT for each beam. Distribution via hardware links to: Beam Dumping System LHC injection kickers SPS Extraction systems Beam interlock user systems. 31.01.2005 J. Wenninger / LEADE

Beam abort and inhibit Any system connected to the beam interlock system that : wants to abort the beam, is not ready for beam ( beam inhibit), must send an interlock (remove its USER_permit signal) in order to remove the beam permit. 31.01.2005 J. Wenninger / LEADE

Safe LHC Parameters There are a number of highly critical pieces of information that must be distributed to machine systems around the ring (beam loss monitoring, BIC, beam dumping system…). Presently : Energy (obtained from main bends currents). Flag to indicate the presence of beam (I > 109 p). Flag to indicate that the beam is safe (I < 1012 p at injection). Under discussion : machine mode (injection, ramp, stable beams…). SLPs (Safe LHC Parameters) It is not yet clear how/if information on the collimators is added to the list. Other candidates are the beam intensities. Note that this system is reserved for CRITICAL parameters. Besides a safe transmission we also have the (at least as critical) issue of a safe generation ! 31.01.2005 J. Wenninger / LEADE

typical “Timing” message: SLP distribution Present idea for the SLP distribution : Re-use hardware from the (millisecond) machine timing system: reliable transmission system, based on VME standard. Speed / bandwidth : 512Kbits and 1ms rate. Easy to re-use Generator and Receptor electronics. Multi-byte format: possible extension for additional parameters. 1st byte P typical “Timing” message: Starting Seq. 2nd byte 3rd byte 4th byte Ending Main users will be chained in a loop – with possibility to add ‘star’ users. Error checking at the end of the loop (with possibility for beam dump). 31.01.2005 J. Wenninger / LEADE

Ring and star distribution RCV S B E T for additional user Fiber optic Fiber optic BLM crate in SR8 to IR1 from IR7 RCV S B E T RCV S B E T IR8 BIC crate in UA87 BIC crate in UA83 31.01.2005 J. Wenninger / LEADE

Software interlock system In addition to the (fast) Hardware Beam Interlock System, the LHC will also have a Software Interlock System : not failsafe, but much more flexible. reaction times ~ many milliseconds to seconds. (much) more complex interlock logic. it will be able to : dump beam (input to the beam interlock system), inhibit extraction from the SPS (input to SPS extraction system), cut beam already in booster (message to Master Timing Generators). This system will be developed for the SPS and the LHC. To be tested in 2006 at the SPS (present SPS system not up to the job for the future). 31.01.2005 J. Wenninger / LEADE

Experiments Each experiment can provide user input signals to the beam interlock system : Background / radiation interlock. Movable device interlock (VELO, RPs). This user signal must be used to : Inhibit injection / SPS extraction if the detector is not ready for beam. Request a beam dump if radiation levels, rates… are so high that the detector may be damaged. Request a beam dump in case of incorrect positioning of movable devices. In addition, software interlocks could / should be generated. The discussion on interlocking of spectrometers magnets will be done by the MPWG directly with PH/DT1 (coming soon) – independent interlock. Separate signals if possible ? 31.01.2005 J. Wenninger / LEADE

Backgrounds, calibration, spectrometers In case of unacceptable ( possible damage) background or radiation : Set a HW interlock to dump beams. Detector calibration (between fills) : Set a HW interlock to dump / prevent injection. Set a software interlock to stop injection – provides information on WHY the beam is stopped. 31.01.2005 J. Wenninger / LEADE

Operation of movable devices Of concern here : roman pots & VELO. Movable devices should only leave their ‘OUT’ position with ‘stable beams’ : Beams are ramped & squeezed  @ physics energy. Beam parameters are OK according to C3. Collimators and absorbers in position. … Please note that stable beams does NOT mean that we will not continue tuning the beams, collimators…. Failures leading to a beam dump within 3 turns are always possible. Beams should be dumped / not injected if a movable device is not ‘OUT’ and the above conditions are not true. 31.01.2005 J. Wenninger / LEADE

Roman pots Roman pots are special since they can ‘compete’ with the collimators in terms of beam scrapping – must ensure they stay in the shadow of the collimators. Proposal 1 (strongly encouraged by collimation WG) : Motors and control of roman pots are identical (or fully compatible) to collimator system. RPs, collimators and absorbers are controlled from a single place to ensure fully consistent positions. Generation of interlocks is taken care by collimator control system. Proposal 2 : RP control must be a ‘slave’ of the collimation control system that dictates position ranges and gives green light for movements. Proper interlock generation is under the responsibility of experiment. 31.01.2005 J. Wenninger / LEADE

Movable devices : conditions Interlock proposal for VELO / RPs not under machine control : The safe conditions for moving devices is encoded in a bit/word that is part of the SLPs and distributed to the concerned experiments. The following interlock condition must be applied : Device out : no interlock, beam OK. Device in + safe conditions : no interlock, beam OK. Device in + unsafe conditions : interlock, beam dump. ‘Normal’ movements should only be allowed when conditions are safe. For movements during access, tests… (i.e. unsafe conditions) an interlock must be set. A additional software interlock should be generated to inhibit extraction from the SPS. 31.01.2005 J. Wenninger / LEADE

It’s just the beginning of the discussions ! Outlook It’s just the beginning of the discussions ! 31.01.2005 J. Wenninger / LEADE

LHCb / ALICE special from SPS operation In parallel to LHC running, the SPS will be running LHC beams without injection into the LHC : Maintain and improve beam quality. Verify steering and beam quality in the long transfer lines TI2 / TI8. A full test of the beam in the SPS down the last dump in front of the LHC injection elements will be required before EVERY LHC filling sequence is started. LHC beam tests of the transfer line imply that muons will be generated in the dump blocks near the LHC tunnel. Those muons fly into the LHCb and ALICE caverns.  We have to look in more detail at the operation of the lines to understand how much beam can be send down the lines and under which conditions. Line operation impossible during LHC physics runs ? What about detector calibrations… between runs ? … 31.01.2005 J. Wenninger / LEADE

Time between a Request to a Beam Dump USER_PERMIT signal changes from TRUE to FALSE a failure has been detected… beam dump request User System process Signals send to LBDS t2 Beam Interlock system process ~70μs max. Kicker fired Beam Dumping System waiting for beam gap t4 all bunches have been extracted ~ 89μs 89μs max time t3 Achievable response time ranges between 100 s and 270 s (between the detection of a beam dump request and the completion of a beam dump) 31.01.2005 J. Wenninger / LEADE

Beam Interlock User Interface From User System to Beam Interlock Crate Receives the USER_PERMIT from a given LHC system. Transmits the USER_PERMIT to the BIC crate. Some User Systems will always provide the USER_PERMIT for both beams. If failure  both beams will be dumped. Some User Systems will dump either Beam 1 or Beam 2. The BEAM_PERMIT status for each beam is provided to the User System. 31.01.2005 J. Wenninger / LEADE