Red-y compact 2. red-y compact 2 compact 2 series Launch 2015 Adding of alarm module 2016 New concept to replace compact 1 series No more Li-Ion battery.

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface VIA ROMA, 20 - I CREAZZO (VI) ITALY PHONE
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
CENTURION™ (C4-SERIES) Erin Cox, Market Research Analyst, Natural Gas Production Controls - Presenter Sanjay Kumar, Market Research Specialist & Product.
Motorcycle product sheets
LogTag Training January 2015
6000 Series Recorders. The Best Paperless Graphic Recorder in the World.
555 Timer ©Paul Godin Updated February Oscillators ◊We have looked at simple oscillator designs using an inverter, and had a brief look at crystal.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Project Goals And Objectives ____________________________________________________ Create a “smart”, customizable, all in one system Little to no learning.
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
Important information & instructions for doing web upgrade :  User needs to backup all his data before doing web upgrade as the same will get deleted.
Profitable Growth B3X Number one to the customer! GT540 Web upgrade Guide Important information & instructions for doing web upgrade :  User needs to.
1 Fluke DAQ Software Visual Demo Guide 2680A-APSW.
MonoDrive & XT Constant Pressure Controller
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
3-Phase Submersible Motor Control
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
WS50(Stratacache) Software updating guide (By Using USB)
Ethernet I/O Set-Up This presentation will step through a typical configuration of the CON-DVT-IOE. Intellect 1.5 is used for the software portion. NEXT.
Multi-Programmer User Guide 1. Contents 1.Product ComponentsProduct Components 2.Software InstallationSoftware Installation 3.Software UseSoftware Use.
ICAICT201A USE COMPUTER OPERATING SYSTEM. USING THE CONTROL PANEL The Control Panel contains many options for configuring your computer, including: adding.
HP laptops are count under the most reliable laptops as they are built with advanced and smart features but still they are not free from some technical.
DIGITAL MULTIMETER DMG
After Construction Name: Per #:.
What are the steps to install a Brother Printer without the CD.
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX i-bus® Tool
Avaya VA Line-interactive UPS
Intro to USB-6009 DAQ.
C1300 advanced circular chart recorder
MMO/MMGO Display Rev03 For Use with Version 25a and newer software.
AUTOMATED security system
Epson XP-640 Tech Support USA & CA
Kevin Boyce Director of Product Management, LED Drivers
System Network Structure
Ping™ 6.
555 Timer EEE DEPARTMENT KUMPAVAT HARPAL( )
2N® Access Unit Touch Keypad
Yeti 400 Reprogram SOP 5/1/2017, Yeti firmware rev. 2.0.
LDA Large Display for Analog Inputs
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
The D.C. Scout Battery Distribution System Ground Locator
Grid feeding monitoring relay
PowerValue 11 RT Sales Presentation
How to Setup and Activate Roku Express with Roku.com/link Account.
Analog Room Command Module
Programmable Logic Controllers (PLCs) An Overview.
2N® Access Unit Touch Keypad
McCrometer Nano Board Test Procedure
About AirPrint AirPrint is an Apple technology that helps you create full-quality printed output without the need to download or install drivers.
AQT90 FLEX Service Training
Vibration Monitoring System M14
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Regulating Battery Charging
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
The bios.
easYgen-3000XT Series Training
724 Temperature Calibrator
Value Series LED Drivers
Presentation transcript:

red-y compact 2

compact 2 series Launch 2015 Adding of alarm module 2016 New concept to replace compact 1 series No more Li-Ion battery but standard AA battery Touch display very versatile instrument, configurable by user No more plastic path for sensor channel Basically same/similar flow path as red-y smart FW-upgrades can be done by user

compact 2 series Versions Battery Version 24V Power Supply Version Unit with Alarm Contacts - Standard AA Battery - Life time 2-3 weeks continuous use - USB Power supply no backlight USB power supply possible incl. backlight (powerbank, laptop, wall plug adaptor) - Cable with fly leads - Cable with plug type power adapter  Backlit display unless disabled Backlit display unless disabled No plug type power adaptor possible

compact 2 alarm module An optional module for the compact 2. Main features are: 3 alarm contacts (relays that can switch up to 1 amp, 30 Vdc) 2 optical isolated input channels (to optionally reset an alarm remotely) Every alarm contact separately settable as high, low, window or totalizer alarm Hysteresis, delay and alarm extension time all customer configurable Built-in 12…30 Vdc power supply, polyfuse protected All variables adjustable locally through the integrated touch screen The alarm module can be easily retrofitted on existing red-y compact 2 meters.

Replaces the battery holder:

Compact 2 alarm module Alarm module with: 24 volt power input 2 inputs 3 alarm contacts 12 colour coded loose wires going out (fly leads)

Functional specs OUT 1 and 2 Switching current output 1, 2 (relay): Rated load: 0.3 A at 125 VAC, 1 A at 24 VDC Max. voltage: 60 VDC,  125 VAC Max. current: 1 A Switching frequency (including de-bounce time):  100 Hz

Technical specification OUT3 Switching current output 3 (relay): Rated load: 3 A Max. voltage: 220VDC, 250VAC Max. current: 4 A Switching frequency (including de-bounce time): 100 Hz

Technical specification IN1 and IN2 Input 1, 2 (opto-coupler):   Voltage range (polarity sensitive): 5 – 30 VDC (@ 5mA max)

Technical specification Power supply : Voltage range : 7 - 42 VDC Max. current : 300 mA Protection : Polyfuse (trip current > 500mA) Reverse polarity protected

Main display compact 2 with alarm Alarm is active Alarm is inactive Alarm is disabled Alarm is enabled

Home Screens with/without Alarm Module

Alarm Home Screens New Home Screens provide more information With alarm module Without Alarm Modul In the menu you can define which home screens are visible

Alarm menu diagram Display view with Alarm Module without Alarm Module

Alarm Configuration Threshold low Alarm Threshold in currently set flow unit Hysteresis for automatic reset of the alarms (in %FS) Delay in ms Minimum alarm duration in ms Translation of the alarm stage in the value at output Source for Reset of the alarms Event to trigger the reset of the alarm

Alarm Configuration Window Alarm Type selection (within or out of window) Upper value of window (in currently set flow unit) Lower value of window (in currently set flow unit) Hysteresis at automatic reset of the alarm (in % of Full Scale). The hysteresis is valid for the upper and the lower threshold likewise.

Alarm Configuration Totalizer Alarm Threshold in currently set flow unit At automatic reset of the Totalizer you need to define in the menu „Reset trigger“ if and how a reset will happen.

Alarm Configuration Flow high alarm with hysteresis and automatic reset

Alarm Configuration Flow high alarm with hysteresis and automatic reset

Alarm Configuration Flow low alarm with alarm duration, automatic reset and inverted output

Alarm Configuration Window alarm with alarm delay and automatic reset

Alarm Configuration Window alarm with alarm delay and automatic reset

Alarm Configuration Totalizer alarm with alarm duration and edge triggered automatic reset

How to update a compact 2 Connect the unit to the computer Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull Some USB can cause problems, especially the long and badly shielded cables. It is recommended to us the Vögtlin supplied cable.

How to update a compact 2 Connect the unit to the computer Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull Restart the unit. During power-up hold your finger on the display for approximately 3 seconds until the unit switches to Service Mode You do not have to unplug the USB cable to restart, you can do this from the menu as well.

How to update a compact 2 Driver is not present Driver is present Connect the unit to the computer Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull When you connect the unit for the first time to the PC, you need to install a driver on your PC. This will be done automatically when you install the update software Driver is present Driver is not present You only have to install the driver once on your PC

How to update a compact 2 Connect the unit to the computer Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull After a successful installation of the driver, it can take some seconds before the PC recognizes the compact You only have to install the driver once on your PC

How to update a compact 2 Connect the unit to the computer Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull After the latest “rescan” the unit will be recognized and you can press Execute to start the update

How to update a compact 2 Connect the unit to the computer Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull After the update the program will give a confirmation that all connected units are updated After the update press the display for about 5 seconds and the unit will start again with the new firmware.

Latest upgrade to FW 3.0.5

Connect to the Vögtlin LinkedIn page for updates

Intuitive operation via touch display!

Flow Control Network – Innovation Award 2016 Great opportunity to promote Vogtlin and compact 2, increase name recognition and create new leads world wide! Compete against Sierra, Emerson, E+H, ITT, Sage, Siemens, etc. Visit https://www.voegtlin.com/en/flow-control- innovation-awards-2016/ to see instruction for voting. Action Plan GET VOTES FOR OUR PRODUCT!!! (internal, external, families, all Berwind corporations, customers, reps, …) Promote on Vogtlin and AW-L websites (pop-ups and special designed page) Connect a competition (Vote and Win) Full page Ad in printed Flow Control Magazine PR in various online magazines E-mail blast in USA and worldwide Social Media Announcement (LinkedIn, Facebook, Twitter, Google+, … share, share, share!) Temporary E-mail signatures

Flow Control Network – Innovation Award 2016

Flow Control Network – Innovation Award 2016