OSHA Office of Training and Education

Slides:



Advertisements
Similar presentations
OSHA Office of Training and Education
Advertisements

Emergency Preparedness and Response
General Requirements Number of exits must be adequate Usually at least 2 exits must be available for evacuation More than 2 exits are required if the.
Emergency Action Plans
Fire Protection OSHA Part 1910 Subpart L.
Fire Prevention & Protection Gordon Cooper Technology Center
1.  Written Plan which describes actions that must be taken to ensure employee safety in emergencies  Includes floor plans or maps which show emergency.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
FIRE PREVENTION & PROTECTION
Fire Prevention and Protection
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
Subpart E Means of Egress.
Coverage and definitions. (a) Every employer is covered
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
Means of Egress Fire Prevention and Protection
Objectives Design and construction requirements for exit routes
Fire Protection John Giefer. Statistics In the Drilling Industry In the Drilling Industry 25% of all inspections found violations of (21 inspections.
1 Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
OSHA Long Term Care Worker Protection Program
Emergency Action Plans/Fire Prevention Plans
Emergency Action Plans
Fire Safety and Fire Extinguishers
Employee Emergency Action Plans and Exit Routes Training Program.
EGRESS AND FIRE PROTECTION

Means of Egress and Fire Protection
NO EXIT (adapted from OSHA Office of Training and Education)
1/05 Means of Egress WAC School Safety Training.
New Hire Initial Fire Safety and Prevention Training MHPHRM BR
Safety Training Presentation
Occupational Safety and Health Course for Healthcare Professionals.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
When to use, how to use. Objective To make all employees aware of the danger posed by fires, and when and how to use fire extinguishers safely SAFETY.
Exit Routes and Fire Protection
Safety & Health Consultation Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Emergency Action Plans
Means of Egress and Fire Protection
Fire Extinguisher Training
Fire Safety Basics Presentation by: Tauni Aikin, Safety and Risk Consultant OmniSure Consulting Group, LLC.
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
Means of Egress Don Ebert- Risk Manager (509)
Fire Protection OSHA Part 1910 Subpart L By: Joshua Spurlin.
EGRESS, FIRE PREVENTION & FIRE PROTECTION OSHA 29 CFR 1910 SUBPARTS E & L Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) 1PPT
Department of Defense Voluntary Protection Programs Center of Excellence Development, Validation, Implementation and Enhancement for a Voluntary Protection.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Emergency Preparedness & Response
Means of Egress and Fire Protection
Hazard Communication This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers.
Emergency Action Plans
Fire Safety.
Fire Extinguisher.
SERVICES, LLC 1 1.
OSHA Most Frequently Cited Serious Violations
Fire Brigades.
Fire Prevention and Protection
Table of Contents for Subpart E Coverage and Definitions
OSHA Office of Training and Education
OSHA Office of Training and Education
Approval Sheets.
29 CFR NFPA Life Safety Code
Jay Industries, Inc. Fire Extinguisher Training Fire Prevention Plan
Fire Extinguisher Training
General Requirements of NFPA 101
Fire Prevention and Protection
Fire Prevention and Protection
Egress and Fire Protection
Disaster Preparedness
Jay Industries, Inc. Fire Extinguisher Training Fire Prevention Plan
Fire Extinguisher Training
Presentation transcript:

OSHA Office of Training and Education Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target audience, this presentation emphasizes hazard identification, avoidance, and control – not standards. No attempt has been made to treat the topic exhaustively. It is essential that trainers tailor their presentations to the needs and understanding of their audience. This presentation is not a substitute for any of the provisions of the Occupational Safety and Health Act of 1970 or for any standards issued by the U.S. Department of Labor. Mention of trade names, commercial products, or organizations does not imply endorsement by the U.S. Department of Labor. OSHA Office of Training and Education

OSHA Office of Training and Education Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long and tragic history of workplace fires in this country caused by problems with fire exits and extinguishing systems OSHA requires employers to provide proper exits, fire fighting equipment, and employee training to prevent fire deaths and injuries in the workplace Exit Routes, Emergency Action Plans, and Fire Prevention Plans: 29 CFR 1910 Subpart E Fire Protection: 29 CFR 1910 Subpart L An employer who demonstrates compliance with the exit route provisions of NFPA 101-2000, the Life Safety Code, will be deemed to be in compliance with the corresponding requirements in 29 CFR 1910.34, 1910.36, and 1910.37. In 1995, more than 75,000 workplace fires cost businesses more than $2.3 billion. OSHA Office of Training and Education

OSHA Office of Training and Education Exit Route A continuous and unobstructed path of exit travel from any point within a workplace to a place of safety (including refuge areas) Consists of three parts: Exit access Exit Exit discharge 29 CFR 1910.34 An exit route includes all vertical and horizontal areas along the route. Exit access is that part of an exit route that leads to an exit. Exit is that part of an exit route that is generally separated from other areas to provide a protected way of travel to the exit discharge. Exit discharge is that part of an exit route that leads directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside. A refuge area is: - A space along an exit route protected from fire by a barrier with at least a 1-hour fire resistance rating; or - A floor with at least 2 spaces, separated from each other by smoke-resistant partitions, in a building protected by an approved automatic sprinkler system. Emphasis is on escaping from fires; however, some additional hazards include explosion,earthquake, bomb threat, toxic vapors, storms (tornadoes, hurricanes, etc.). Compounding factors that may interfere with safe escape include panic and confusion, poor visibility, lack of information, and misinformation. These factors frequently cause more injuries and fatalities than the hazard itself. OSHA Office of Training and Education

Exit Routes Basic Requirements Exit routes must be permanent and there must be enough exits in the proper arrangement for quick escape Exits must be separated by fire-resistant materials Openings into an exit must be limited to those necessary to allow access to the exit or to the exit discharge An opening into an exit must be protected by an approved self-closing fire door that remains closed or automatically closes in an emergency 1910.36(a) and (b) 1910.37(d): Exit routes must be maintained during construction, repairs, or alterations OSHA Office of Training and Education

OSHA Office of Training and Education Exit Discharge Each exit discharge must lead directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside that is large enough to accommodate all building occupants likely to use the exit route Exit stairs that continue beyond the level on which the exit discharge is located must be interrupted on that level by doors, partitions, or other effective means that clearly indicate the direction of travel to the exit discharge 1910.36(c) OSHA Office of Training and Education

Exit Doors Must Be Unlocked Must be able to open from the inside at all times without keys, tools, or special knowledge Device such as a panic bar that locks only from the outside is permitted Must be free of any device or alarm that could restrict emergency use if the device or alarm fails May be locked from the inside only in mental, penal, or correctional facilities where there is constant supervision 1910.36(d) Locked and blocked exit OSHA Office of Training and Education

OSHA Office of Training and Education Side-Hinged Exit Door Must be used to connect any room to an exit route A door that connects any room to an exit route must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or contains high hazard contents 1910.36(e) High hazard contents are those which are liable to burn with extreme rapidity or which may produce poisonous fumes or explosions in a fire. Examples include flammable chemicals and grain. OSHA Office of Training and Education

Exit Route Capacity and Dimensions Must support the maximum permitted occupant load for each floor served Capacity must not decrease in the direction of exit route travel to the exit discharge Ceiling must be at least 7-½ ft. high with no projection reaching a point less than 6 ft.-8 in. from floor An exit access must be at least 28 in. wide at all points 1910.36(f) and (g) Information regarding “Occupant Load” is located in NFPA 101-2000, Life Safety Code. Objects that project into the exit route must not reduce the width of the exit route to less than the minimum width requirements for exit routes. An outdoor exit route is permitted if it meets the requirements of 1910.36(h). OSHA Office of Training and Education

Minimize Danger to Employees Exit routes must be free and unobstructed Keep exit routes free of explosive or highly flammable materials Arrange exit routes so that employees will not have to travel toward a high hazard area, unless it is effectively shielded Emergency safeguards (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times 1910.37(a) 1910.37(b)(1): Each exit route must be adequately lighted so that an employee with normal vision can see along the exit route Obstructed exit route OSHA Office of Training and Education

OSHA Office of Training and Education Exit Marking Each exit must be clearly visible and marked with an “Exit” sign Each exit route door must be free of decorations or signs that obscure the visibility of the door 1910.37(b)(2) and (3) OSHA Office of Training and Education

OSHA Office of Training and Education Exit Marking (cont’d) If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating direction to the nearest exit The line-of-sight to an exit sign must clearly be visible at all times 1910.37(b)(4) OSHA Office of Training and Education

OSHA Office of Training and Education Exit Marking (cont’d) Each doorway or passage along an exit access that could be mistaken for an exit must be marked “Not an Exit” or similar designation, or be identified by a sign indicating its actual use (e.g., closet). 1910.37(b)(5) OSHA Office of Training and Education

OSHA Office of Training and Education Emergency Action Plan Describes actions that must be taken to ensure employee safety in emergencies Includes floor plans or maps which show emergency escape routes Tells employees what actions to take in emergency situations Covers reasonably expected emergencies, such as fires, explosions, toxic chemical releases, hurricanes, tornadoes, blizzards, and floods 1910.38(a) applies to all emergency action plans required by a particular OSHA standard, such as the Fire Brigades or Permit-Required Confined Spaces standard. The emergency action plan must be in writing, except for firms with 10 or fewer employees. These businesses can communicate the plan orally to employees. Emergency plans include, as a minimum: - Escape procedures and escape route assignments - Critical plant operations shutdown procedure - Procedure to account for all personnel - Assignment of rescue and medical duties - Means for reporting emergencies - Identification of responsible persons to contact for further information Employee training is necessary and an alarm system must be in place which has a distinctive signal. See OSHA Publication 3088, “How to Prepare for Workplace Emergencies,” available at www.osha.gov for more information. OSHA Office of Training and Education

OSHA Office of Training and Education Fire Prevention Plan The plan must include: A list of the major fire hazards and handling, storage, and control procedures Names or job titles of persons responsible for maintenance of equipment and systems to prevent or control ignitions or fires Names or job titles of persons responsible for control of fuel source hazards Training for all employees who have responsibilities in the plan 1910.39 applies to all fire prevention plans required by a particular OSHA standard. The fire prevention plan must be in writing, except for firms with 10 or fewer employees. Those businesses can communicate the plan orally to employees. Accumulations of flammable and combustible waste materials and residues must be controlled so they do not contribute to a fire emergency. Currently a fire prevention plan is required by OSHA only where an employer’s written policy: - Requires immediate and total evacuation of the workplace upon the sounding of a fire alarm signal - Establishes an appropriate emergency action plan - Prohibits employee use of fire extinguishers See 1910.157(b) OSHA Office of Training and Education

Portable Fire Extinguishers If portable fire extinguishers are provided for employee use, the employer must mount, locate and identify them so workers can access them without subjecting themselves to possible injury. 1910.157(c)(1) Employers can choose whether to train their workers to fight fires or to rely on outside services. Blocked extinguisher OSHA Office of Training and Education

Extinguisher Classification Letter classification given an extinguisher to designate the class or classes of fire on which it will be effective. Class A – ordinary combustibles (wood, cloth, paper) Class B – flammable liquids, gases, greases Class C – energized electrical equipment Class D – combustible metals Combustible The class of extinguisher should be on the extinguisher shell. The picture-symbol labeling system now in use is designed to make the operation of fire extinguishers more effective and safe to use through the use of less confusing pictorial labels. The system also emphasizes when not to use an extinguisher on certain types of fires. Because of recent information outlining the difficulties inherent in the extinguishment of fires in cooking appliances that involve combustible cooking media (vegetable or animal oils and fats), a new classification (Class K) has been established. This classification is not listed in OSHA standards. NFPA 10 specifies that listed and labeled Class K fire extinguishers are to be provided in these cases. Class A Class B Class C Class K Ordinary Flammable Electrical B C A D Combustibles Liquids Equipment Metals OSHA Office of Training and Education

OSHA Office of Training and Education Extinguisher Rating Numerical rating given to Class A and B extinguishers which indicate how large a fire an experienced person can put out with the extinguisher Ratings are based on tests conducted at Underwriters’ Laboratories, Inc. Class A: 1-A, 2-A, . . . 40-A Class B: 1-B, 2-B, . . . 640-B A 4-A extinguisher, for example, should extinguish about twice as much fire as a 2-A extinguisher Class C extinguishers have only a letter rating because there is no readily measurable quantity for Class C fires which are essentially Class A or B fires involving energized electrical equipment. Class D extinguishers likewise do not have a numerical rating. Their effectiveness is described on the faceplate. OSHA Office of Training and Education

Maintaining Portable Fire Extinguishers Must maintain in a fully charged and operable condition Must keep in their designated places at all times except during use Must conduct an annual maintenance check Must record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less 1910.157(c)(4) 1910.157(e)(3) OSHA Office of Training and Education

Portable Fire Extinguisher Training and Education Where portable fire extinguishers have been provided for employee use in the workplace, employees must be provided with an educational program on the: General principles of fire extinguisher use Hazards of incipient (beginning) stage fire fighting Employees designated to use extinguishers must receive instruction and hands-on practice in the operation of equipment 1910.157(g) Training and education required upon initial employment/assignment and at least annually thereafter. “Incipient Stage Fire” means a fire which is in the initial or beginning stage and which can be controlled or extinguished by portable fire extinguishers, Class II standpipe or small hose systems without the need for protective clothing or breathing apparatus. [1910.155(c)(26)] OSHA Office of Training and Education

OSHA Office of Training and Education Summary There must be enough exits in the proper arrangement for quick escape Exit routes must be marked, lighted, free of obstructions, and locks must not be used to impede or prevent escape An emergency action plan and a fire prevention plan must be in place Fire extinguisher classes and numerical ratings help a user understand its capabilities Fire extinguishers must be inspected, maintained and employees must be trained in how to use them OSHA Office of Training and Education