Marco Statera on behalf of the LASA team INFN Milano - LASA

Slides:



Advertisements
Similar presentations
MQXF Quench Protection Analysis HiLumi workshop – KEK, Tsukuba Vittorio Marinozzi 11/18/2014.
Advertisements

HL-LHC Corrector Magnet 3D design status Giovanni Volpini on behalf of the LASA team CERN, February 25, 2014.
ISTITUTO NAZIONALE DI FISICA NUCLEARE SEZIONE DI MILANO LABORATORIO ACCELERATORI E SUPERCONDUTTIVITA’ APPLICATA Magnet Test LASA, INFN-Milano.
F. Savary on behalf of the WP11 team Input from V. Baglin, D. Ramos.
HL-LHC Corrector Magnet Design & Construction Activity Status Giovanni Volpini on behalf of the LASA team CERN, January
Paolo Fessia, Ezio Todesco
HL-LHC IR Higher Order Corrector Magnets Conceptual Design & Construction Activity F. Alessandria, G. Bellomo, F. Broggi, A. Paccalini, D. Pedrini, A.Leone,
E. Todesco PROPOSAL OF APERTURE FOR THE INNER TRIPLET E. Todesco CERN, Geneva Switzerland With relevant inputs from colleagues F. Cerutti, S. Fartoukh,
HL-LHC/LARP, QXF Test Facility Workshop– R. Carcagno QXF Test Requirements Ruben Carcagno BNL Workshop December 17, 2013.
Thoughts about the MQXF development plan P. Fessia Thanks to discussions within the MDT section (P. Ferracin, J. C. Perez, E. Todesco, P. Ferracin), L.
LARP CM15 Magnet Testing Working Group SLAC, November 2 nd 2010.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
ISTITUTO NAZIONALE DI FISICA NUCLEARE SEZIONE DI MILANO LABORATORIO ACCELERATORI E SUPERCONDUTTIVITA’ APPLICATA Magnet Test LASA, INFN-Milano.
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
Joint HiLumi LHC-LARP Meeting – May 11-13, 2015 MQXFA Functional Requirements Ruben Carcagno May 13,
Review of Quench Limits FermilabAccelerator Physics Center Nikolai Mokhov Fermilab 1 st HiLumi LHC / LARP Collaboration Meeting CERN November 16-18, 2011.
5 th Joint Hi-Lumi LHC-LARP Annual Meeting 2015 SC Link Protection A.Ballarino 28/10/2015.
High Order Corrector Magnets Status F. Alessandria, G. Bellomo, F. Broggi, A. Paccalini, D. Pedrini, A.Leone, V. Marinozzi, M. Quadrio, M. Sorbi, M. Statera,
Superconducting Technologies for the Next Generation of Accelerators CERN, Globe of Science and Innovation 4-5 December Superconducting Links for the Hi-Lumi.
Q4 MAGNETS FOR HL-LHC J.M. Rifflet, M. Segreti, E. Todesco WP3 - Q4 magnets for HL-LHC 5th Joint HiLumi LHC-LARP Annual meeting Research supported.
Quench Protection Maximum Voltages G. Ambrosio, V. Marinozzi, M. Sorbi WG Video-Mtg January 14, 2015.
E. Todesco INTERACTION REGION MAGNETS E. Todesco On behalf of the WP3 collaboration CERN, Geneva, Switzerland CERN, 27 th October 2015.
Cosine-theta configurations for S.C. Dipole Massimo Sorbi on behalf of: INFN LASA & Genova Team Giovanni Bellomo, Pasquale Fabbricarore, Stefania Farinon,
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
Super Fragment Separator (Super-FRS) Machine and Magnets H. Leibrock, GSI Darmstadt Review on Cryogenics, February 27th, 2012, GSI Darmstadt.
Study of the HTS Insert Quench Protection M. Sorbi and A. Stenvall 1 HFM-EuCARD, ESAC meeting, WP 7.4.1CEA Saclay 28 feb. 2013,
MQXFS1 Test Results G. Chlachidze, J. DiMarco, S. Izquierdo-Bermudez, E. Ravaioli, S. Stoynev, T. Strauss et al. Joint LARP CM26/Hi-Lumi Meeting SLAC May.
2 nd LARP / HiLumi Collaboration Mtg, May 9, 2012LHQ Goals and Status – G. Ambrosio 11 Quench Protection of Long Nb 3 Sn Quads Giorgio Ambrosio Fermilab.
Logo area HL LHC IT STRING M. Bajko CERN TE-TM and QXF Review.
The High Luminosity LHC Project
FNAL Workshop, July 19, 2007 ILC Main Linac Superconducting Quadrupole V.Kashikhin 1 ILC Main Linac Superconducting Quadrupole (ILC HGQ1) V. Kashikhin.
Superconducting Cryogen Free Splittable Quadrupole for Linear Accelerators Progress Report V. Kashikhin for the FNAL Superconducting Magnet Team (presented.
September 27, 2007 ILC Main Linac - KOF 1 ILC Main Linac Superconducting Quadrupole V. Kashikhin for Magnet group.
CERN QXF Conductor Procurement and Cable R&D A.Ballarino, B. Bordini and L. Oberli CERN, TE-MSC-SCD LARP Meeting, Napa, 9 April 2013.
WP10 General Meeting, Giovanni Volpini, CERN 1 December 2015 Test progress INFN 1.
Jim Kerby Fermilab With many thanks to Vladimir Kashikhin, the FNAL, KEK, and Toshiba teams. SCRF BTR Split Quadrupole ILC ML & SCRF Baseline Technical.
CERN, 11th November 2011 Hi-lumi meeting
Results from the cold test of the first QD0 prototype
HL-LHC Magnet components and assemblies
Massimo Sorbi on behalf of INFN team:
MQXC Nb-Ti 120mm 120T/m 2m models
Status of QLASA Tool Adapter
WORK IN PROGRESS F C C Main Quadrupoles FCC week 2017
SLHC –PP WP6 LHC IR Upgrade - Phase I.
Model magnet test results at FNAL
MQY-30 Test Result Report
11 T Dipole Integration & Plans M. Karppinen
HO correctors update Massimo Sorbi and Marco Statera
HO Corrector Magnets: decapole test and future plans
High Order correctors coil manufacturing
MQXF Goals & Plans G. Ambrosio MQXF Conductor Review
Circuits description and requirements
Agenda 9:00  - Welcome ASG speaker 9:10 -  Introduction -       P.Fabbricatore 9:25 - The D2   magnets in HL-LHC   -  E. Todesco.
MMI^2T limits for magnets, what are they and how where they developed
JLAB MEETING FDR – April 23-24th 2013
Quench protection of the MAGIX high-order correctors
Powering the LHC Magnets
HO Corrector Magnets: decapole test and future plans
HL-LHC Corrector Magnet Design & Construction Activity Status
Quench Protection Measurements & Analysis
Circuits description and requirements - Closed Session-
Introduction to the technical content The Q4 magnet (MQYY) for HL-LHC
Detailed global view on protection and detection of the circuits
MQXF coil cross-section status
HL-LHC IR Corrector Magnets Conceptual Design & Construction Activity
PROPOSAL OF APERTURE FOR THE INNER TRIPLET
as a prototype for Super c-tau factory
Quench calculations of the CBM magnet
Review of Quench Limits
Electrical integrity of magnets and coils
Presentation transcript:

Marco Statera on behalf of the LASA team INFN Milano - LASA Progetto HiLumi I magneti correttori di alto ordine INFN Milano - consiglio di sezione – 10 Luglio 2018 Marco Statera on behalf of the LASA team INFN Milano - LASA

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies octupole MCOXF and decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

HiLumi LHC The main objective of HiLumi LHC Design Study is to determine a hardware configuration and a set of beam parameters that will allow the LHC to reach the following targets: A peak luminosity of Lpeak = 5×1034 cm-2s-1 with levelling, allowing: An integrated luminosity of 250 fb-1 per year, enabling the goal of Lint = 3000 fb-1 twelve years after the upgrade. This luminosity is more than ten times the luminosity reach of the first 10 years of the LHC lifetime. Courtesy of L. Rossi HiLumi High Order Correctors – M. Statera

HiLumi LHC landmarks Hilumi LHC a project for Physics and Technology jump Courtesy of L. Rossi HiLumi High Order Correctors – M. Statera

SCOPE The INFN-LASA follows the design, construction and test of the 5 prototypes of the high order (HO) corrector magnets for the HL interaction regions of HiLUMI (KE2291/TE/HL-LHC) This activity is founded by INFN (Magix “activity”), and with an agreement CERN contributes for about 50% The INFN-LASA follows the series production (KE3085/TE/HL-LHC) ~70 m b6 a6 b5 a5 b4 a4 b3 a3 a2 by P. Fessia HiLumi High Order Correctors – M. Statera

HO CORRECTOR MAGNETS ZOO OD460 a2 MQSXF MCSXF MCOXF OD320 ✔ a3 b3 a4 b4 ✔ a5 b5 ✔ a6 b6 NbTi superconducting coils superferric design 60% margin @ 1.9 K existing power supplies no energy extraction (but 4P) MgB2 round coil MCDXF MCTXF HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies octupole MCOXF and decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

(35 MGy the previous estimate) Validated Materials (for coils) COILS STUDIES ISSUE: radiation 15 MGy recalculated (35 MGy the previous estimate) Validated Materials (for coils) Duratron BTS2 by Arisawa Hybrid BTS2/Duratron 8 coils duratron 5 coils BTS2 5 coils hybrid HiLumi High Order Correctors – M. Statera

COILS machined from bulk 4 parts machined from bulk 0.15 mm BTS2 1.05 mm BTS2 1.3÷1.5 mm DURATRON >1 mm BTS2 – new design machined from bulk HiLumi High Order Correctors – M. Statera

FINAL DESIGN One technology for all HO correctors coils 7-8 parts BTS2 (up to 12 in the previous version) Machined from bulk In & out 1.0 mm sheet 0.15 mm HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies octupole MCOXF and decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

integrated field @ Iop @ r50 mm MCOXFP1 nominal design length 160 mm 183 mm integrated field @ Iop @ r50 mm 46 Tmm magnetic length 87 mm 99 mm energy @Iop 1.4 kJ 1.07 kJ harmonics B12=11.6 B20=-3.0 DURATRON PEI U2300 coils electrical connections redesigned 183 mm HiLumi High Order Correctors – M. Statera OD 320 mm

new electrical connections MCOXFP1 ASSEMBLY 1 assembly procedure same as 6pole new electrical connections lamination Copper 2 mm wide 0.035 mm thick two printed circuit boards coils’ connections signals alignment frame spacers fixed longitudinally wedges in position the wedges are fixed CuBe rods HiLumi High Order Correctors – M. Statera

MCOXFP1 ASSEMBLY 2 HiLumi High Order Correctors – M. Statera

HEATERS 10.1 J 4.4 J Two heaters are installed DURATRON thickness reduced by hand in coil B5 A Φ 2 mm Aluminum nitride (AlN) ceramic insert in one hole of coil B6 quench induced at 4.2 K, I= 73 A 10.1 J 4.4 J AlN 1 mm thick By INTELLION S.a.r.l. HiLumi High Order Correctors – M. Statera

working condition test w/o energy extraction thermal cycle 8POLE TEST qualification @ 4.2 K qualification 1h @ 108% @2.17 K training @4.2 K working condition test w/o energy extraction thermal cycle HiLumi High Order Correctors – M. Statera

MCOXFP1 COILS 12 coils produced HCMCOXFC01-I1000001 coils’ assessment single coil’s cold test: 2 training quenches reached short sample sample 247 A nominal current s.s.l. 12 coils produced  HCMCOXFC01-I1000001  heigth inner long outer long inner short B1 M08-01 B2 M08-08 B3 M08-07 B4 M08-06 B5 M08-09 B6 M08-10 B7 M08-11 B8 M08-12 coils’ assessment Geometry 6pole average s 0.09 mm 8pole average s 0.13 mm Resistance number of turns HV insulation all coils above 1.8 TW at 5 kV HiLumi High Order Correctors – M. Statera

8POLE COLD TEST RESULTS stable at ultimate current (108% Inom) and at 150% Inom 26 quenches – Imax= 207 A (89.2 % s.s.l.) HiLumi High Order Correctors – M. Statera

8POLE COLD TEST RESULTS - 2 He II test: 2.17 K 1h @ 108% Inom (114 A) 1h @ 150% Inom (158 A) no quenches occurred 1h@ 150% In qualification 1h@ 108% In tests @ 4.2 K full training: Imax 89% of s.s.l. working condition test qualification @4.2 K after a thermal cycle HiLumi High Order Correctors – M. Statera

QUENCH PROTECTION IN LHC Existing power supplies Measuring current Time range 60-180 ms Max current: ultimate current (114 A) Protection at LASA Total voltage and differential voltage (half magnet) Quench induced by heater (and AlN insert) HiLumi High Order Correctors – M. Statera

QUENCH PROTECTION (no ENERGY EXTRACTION) Quech induced by heater (and AlN insert) threshold up to 5.0 V total time before relay opening: 145 ms DI = 8 A @ 145 ms PS dependent tuning of the simulation by QLASA inductance current decay voltages 200 ms training no dump time HiLumi High Order Correctors – M. Statera

PRELIMINARY FIELD MEASUREMENT preliminary measurement of the field single point in front of a pole radius of 50±1 mm (correction applied) reproducible 5 mT saturation 30 A complete measurement at CERN (2018) HiLumi High Order Correctors – M. Statera

integrated field @ Iop @ r50 mm MCDXFP1 10-POLE length 183 mm integrated field @ Iop @ r50 mm 26 Tmm magnetic length 97 mm harmonics <15 U 5 coils BTS2 5 coils hybrid Tested in Sept 2017 COILS Updated BTS2 Arisawa design Hybrid BTS2/DURATRON Improved electrical connection design, pcbs supporting and integration with connection box HiLumi High Order Correctors – M. Statera

ASSEMBLY New supports for connection PCBs Updated design wedge HiLumi High Order Correctors – M. Statera

ELECTRICAL CONNECTIONS LASA connection box CERN copper for bus bar connection Diagnostic (prototypes) bridge upper PCB lower PCB PCBs fixing CERN connection box HiLumi High Order Correctors – M. Statera

10-POLE COLD TEST RESULTS B3-B4 B7-B8 B9-B10 event number Ultimate 114 A -1 h test Reached 100% S.S.L at 4.2 K Quench protection w/o energy extraction HiLumi High Order Correctors – M. Statera

max voltage to ground in operation <150 V GROUND INSULATION max voltage to ground in operation <150 V hot spot temperature in operation <200 K 10 mA limit IEEE Standard 95-177 VRT= (2 x Vmax+500) x 2 HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies octupole MCOXF and decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

BASELINE CHANGES CERN requirements for magnet performances changed HL – LHC Engineering Change Request CHANGE OF QUADRUPOLE, SEXTUPOLE, OCTUPOLE AND DECAPOLE CORRECTORS INTEGRATED FIELD AND LENGTH EDMS 1865591 6-pole, 8-pole and 10-pole are requested to have 50% of more integrated field increasing length or 50-60 mm (magnetic design, protection scheme, integration) 4-pole 30% decrease of integrated field Length reduction 276 mm (magnetic design, protection scheme, integration) Ongoing integration work between CERN and to manage the increased length of the cold mass (+320 mm -276 mm) Small cost revisions may be necessary (probably ~5%), and they can be discussed after the consolidation of the final design HiLumi High Order Correctors – M. Statera

Engineering ✓ Protection ✓ Integration ✓ LENGTHS MQXF 4P S MCSXF 6P N/S MCOXF 8P N/S MCDXF 10P N/S MCTSXF 12P S MCTXF 12P N integrated field variation -30% +50% Length prototype 814.0 194.0 183.0 575.0 Updated length prototype 538.0 Updated length series 540.4 251.4 234.6 205.6 576.8 Engineering ✓ Protection ✓ Integration ✓ HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies the decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

DODECAPOLE MCTXFP1 and SKEW QUADRUPOLE MCQSXFP1 Electromagnetic and mechanical design finalized OD320 575 mm Iop=105 A NO energy extraction in operation 432 windings - F 0.5 mm NbTi PCB Connection box Iop=182 A Energy extraction in operation 754 windings - F 0.7 mm NbTi Coils’ length 457 mm 538 mm SC coil pole wedge OD 460 mm HiLumi High Order Correctors – M. Statera

PRODUCTION IN INDUSTRY Long prototypes produced in industry New winding machine New custom vacuum oven HiLumi High Order Correctors – M. Statera

PRODUCTION IN INDUSTRY 2 2 test coils produced First coil produced in industry Long prototypes’ test MCTXFP1 in September MCQSXFP1 in November HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies the decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

ROUND COIL MAGNET SCHEDULE Winding MgB2 wire 2017 Impregnation 2017 Fe coil 100 mm f 380 SCHEDULE Winding MgB2 wire 2017 Impregnation 2017 Cold test of the coil 2018 Magnet assembly 2018 demonstrator G. Volpini et al. Eletromagnetic Study of a Round Coil Superferric Magnet,IEEE Tr. App. Sup, 26, 4 (2016) multipolar MgB2 magnet inner bore f 150 mm single MgB2 coil bare diameter 1 mm electromagnetic design working point 133 A @4.2 K margin 48 % on the load line adiabatic hot spot temperature < 90 K winding @ LASA HiLumi High Order Correctors – M. Statera

RCSM Single Coil Test No quench training Hall probe Conical springs PCB Strain gages BUS BAR soldering MgB2 winding BTS2 No quench training The Coil is stable at the Ultimate Current (108% Iop) 73% of the Short Sample Limit M. Sorbi, M Statera and E. Todesco March 2018 HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies the decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

INTEGRATION integration in the cold mass ongoing position in cold mass no magnetic coupling alignment cabling fix threads and nuts by resin (CTD 101K) and anti vibration washers position and diameter for the Heat Exchanger (MCQSXFP) integration in the power grid and electrical tests all magnets but quadrupole no energy extraction (simulation and test) defining quench protection parameters (thresholds, Dt, resistance and protection circuit) defining voltage tests (focus on series production) HiLumi High Order Correctors – M. Statera

All produced prototypes are in MTF/EDMS Integration DOCUMENTATION All produced prototypes are in MTF/EDMS Test reports and test summaries Acceptance procedures Workflow MIPs NC HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies the decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

Mechanical interface with dicorap cryostat Mag.meas. HiLumi CRYOSTAT Safety Valve and disk He inlet Cryostat for testing MCTXFP1 (12P), MCQSXFP1 (4P) and series magnets 4 K operation 515 mm inner diameter Hosted within DISCORAP cryostat (which acts as a support) About 3 m high Up to 4 magnets (3 possible configurations) Flange modification, thermal insulation, magnet support, room temperature connections. Mechanical interface with dicorap cryostat CL 2+4 HiLumi High Order Correctors – M. Statera

Small Magnets test cryostat SC magnet test area Small Magnets test cryostat HO correctors protoypes 6P MCSXFP (MCSXF/MCSSXF) 8P MCOXFP (MCOXF/MCOSXF) 10P MCDXFP (MCDXF/MCDSXF) High Current Test Station DISCORAP and HTS magnets HO correctors 12P MCTXFP 4P MQSXFP HiLumi HO correctors series MAGIX D 480 mm h 1200 mm 4.2 K and 2.17 K 500 A DISCORAP D 695 mm h 7200 mm 4.2 K 10 kA HiLumi D 515 mm H 2950 mm 4.2 K 500 A HiLumi High Order Correctors – M. Statera

Commissioning ongoing TEST STATION 600 mm 2350 mm 12P 4P Commissioning ongoing Prototypes Single magnet test Series production 3 batches 18 magnets 2X12P 2X4P 5 cooldowns Designed to host a field quality system by CERN HiLumi High Order Correctors – M. Statera

COMMISSIONING 1 SOFTWARE Quench protection Fast DAQ CABLING Slow control CABLING MECHANICS BUS BARS Each HO corrector 1 common CL + bus bar 1 dedicated CL + bus bar 3 voltage taps HiLumi High Order Correctors – M. Statera

COMMISSIONING 2 AAA HiLumi cryostat 10 kA line pumping station Discorap cryostat Nitrogen heat exchanger HiLumi High Order Correctors – M. Statera

scope: the High Order correctors magnets coils studies OUTLINE scope: the High Order correctors magnets coils studies the decapole MCDXF : cold test results baseline changes dodecapole MCTXF and quadrupole MQSXF Round Coil Superconducting Magnet Integration new cryostat for series and long prototypes next steps HiLumi High Order Correctors – M. Statera

2019 start series production (54 magnets) NEXT STEPS Sept 2018 test MCTXFP1 Nov 2018 test MCQSXFP1 Magnetic measurement @LASA? 2019 start series production (54 magnets) HiLumi High Order Correctors – M. Statera

Construction of the series The engineering design of the series completed as scheduled in July 2018 (M1.1) Technical and Contractual documents for the tender completed Approval by INFN Executive Board in mid July 2018 Launch the tender within Sept. 2018 Signature of contract. Jan. 2019 (D1.1) 6 cold masses (9 mangnets each) Last delivery to CERN in Sept. 2021 HiLumi High Order Correctors – M. Statera

Hold point for series construction An Hold Point has been set after the delivery to LASA of the first set of 9 magnets (a entire cold mass) We want to test at least the modified magnets (6-pole, 8-pole, 10-pole) to verify the requested modification respect to prototypes. The production has to be stopped for 2 months This allows to have a first set of 9 magnets on time or earlier (at CERN in Jan. 2020) Last delivery to CERN in Sept. 2021 HiLumi High Order Correctors – M. Statera

Status of the HO correctors prototypes production and test CONCLUSIONS Status of the HO correctors prototypes production and test Baseline changes Integration New test stand for long prototypes and series Next steps HiLumi High Order Correctors – M. Statera

THANK YOU CERN: A. Musso LASA: F. Alessandria, G. Bellomo, F. Broggi, S. Mariotto, A. Paccalini, A. Pasini, D. Pedrini, A. Leone, M. Quadrio, M. Sorbi, M. Statera, M. Todero, R. Valente, C. Uva HiLumi High Order Correctors – M. Statera