INFRARED THERMOGRAPHY ELECTRICAL INSPECTIONS .

Slides:



Advertisements
Similar presentations
An Introduction to On-line Partial Discharge Surveys
Advertisements

Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Preventing Equipment Failures
Thermography Adam Adgar School of Computing and Technology.
Basic Electric for heating What is Electricity?
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
Thermal Imaging & Trace & Access Nick Jeffery Training Manager.
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
Visit us at … Advanced Infrared & Patented Acoustics Inspectors SEE & HEAR through walls and floors We can diagnose issues that visual.
Reducing maintenance expense while improving patient safety by predicting electrical system failures University of Pittsburgh Medical Center Pittsburgh,
Maintenance At Your WWTP August 2010
Slide 1 UNCLASSIFIED Breaker Operation Arc Flash Breakout Group EFCOG Electrical Safety Workshop – July 18, 2014.
Advanced Evaluation Techniques Regarding Combustible Dust Inspections for “Combustible Dust” and their contributory conditions are mostly “VISUAL”. “Advanced”
EET Survey of Electronics
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
Electrical Power Systems
Electrical Preventive Maintenance What is the definition of Electrical Preventive Maintenance?
Thermographic Testing Vibrotech Reliability Services Limited.
Department of Mechanical Engineering HumilityEntrepreneurshipTeamwork LearningSocial ResponsibilityRespect for Individual Deliver The Promise BS&H, GMR.
Circuit Protection n Types of Fused Protection How to pull them.
OVERVIEW COMBUSTIBLE DUST QUIZ: Management Level Produced under OSHA Susan Harwood Grant SH
Infrared Thermography
What is Thermography?. Infrared thermography is the collection & analysis of radiated electromagnetic energy in the infrared portion of the electromagnetic.
INFRARED THERMOGRAPHY ELECTRICAL INSPECTIONS .
2013 NATEF Task Area A-7 Heating, Ventilation, and A/C A. A/C System Diagnosis & Repair B. Refrigeration System Component D & R C. Heating, Ventilation.
Troubleshooting Electric Control Devices
Electrical Principles and Wiring Materials
4/22/2017 WHAT IS THERMOGRAPHY?
Electrical Distribution Systems
Air Handler Terminology
Air Handler Terminology
IR Thermography Infra Red Thermography is a technique for producing a visible image of invisible (to our eyes). Infra red radiation emitted by objects.
Using Infrared to Proactively Maintain the Distribution System Ben J Carranza.
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Shore Power System General Location. Shore Power Power comes on to the vessel in the form of 480 Volt, Three Phase, 60 Hz Alternating Current (A/C) electricity.
Glades Electric Cooperative Infrastructure Miles of Line 2,213  Overhead Dist.2,180  UndergroundDist. 33  Transmission 87 16,402 meters Average 7.
Modern Maintenance. Management
THERMOGRAPHY Presented By: Nagaraj S Patil. Contents Introduction What it is? Where it is used? What makes it useful? Principle Application Advantages.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Residential Wiring Unit 3 – Installation and Planning.
GENERATORS A Large Piece of Equipment That Gets Ignored!
Residential Wiring Unit 3 – Installation and Planning Chaps 9-12.
Lime Kiln Monitoring High Temperature Cameras
9. Sample Infrared Images
INFRARED THERMOGRAPHY
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Draught Finder Trevor Clark Qualified Thermographer
Electrical Principles and Wiring Materials
Chapter 12 Branch Circuits and Feeders. Chapter 12 Branch Circuits and Feeders.
Engineering Technology Division
Draught Finder Trevor Clark 8. Thermal Infrared Inspections
Infrared Inspection Services in UAE
"Don't Get Amped Up! Electrical Safety to Keep Your Team Grounded!"
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Associated Hazards and Safety Practices
Emergency Electrical Power Supply for Buildings
ELECTRICAL POWER-II Electrical engineering sixth semester
Circuit Analysis and Troubleshooting
EET 323 – Electrical System Design Lecture 11: Panel-boards and Switch-boards Instructor: Radian Belu, PhD.
Independently owned and operated
22 Chapter Basic Electrical Tests. 22 Chapter Basic Electrical Tests.
Electrical Principles and Wiring Materials
Electrical components and systems
The new Fluke Thermography Lineup
Presentation transcript:

INFRARED THERMOGRAPHY ELECTRICAL INSPECTIONS . Recent technical manuals published by National Fire Protection Association (NFPA) and the Inter-National Electrical Testing Association (NETA) prominently recommend the use of infrared inspection in the testing and maintenance of electrical systems Dan Playforth Thermographer Level II

. Wavelength is longer than visible light. Infrared Radiation Infrared waves are not visible by the eye . Wavelength is longer than visible light.

Infrared Thermography An Infrared Camera Senses Infrared Radiation A Processor In The Camera Assigns Color To The Infrared Radiation-Different Color Equals Different Temperature Enabling Us To Visualize The Thermal World

Infrared Image Color Palette Range Is Chosen For Clarity Palette 2 Is Better Suited For This Image Color Palette 2 White = T>95F Black = T<72F Color Palette 1 White = T>85F Black = T<72F 1 2

Some Uses Of Infrared Thermography Medical Severe Acute Respiratory Syndrome (SARS) Manufacturing Processes Plastics Carpet Heat/Chilling Processes Mill Operations Slag Detection Police Work Fugitive Search Drug Enforcement Missing Persons Search Animal Equine Hot Joints Ligaments Electrical Inspections Hot Connections Failing Components Overloaded Circuits Mechanical Inspections Motors, Bearings, Drives, Steam Systems, Boilers Fire Hot Spots People Rescue Building Thermal Envelope Roof Leaks Military

Benefits of Periodic Electrical Infrared Inspections Predictive Maintenance...Allows Scheduling Of Repairs, Forward Buying Reduces Downtime… Find It, Repair It, Before It Blows Up and Stops Production

Qualitative Infrared Electrical Inspection Qualitative Inspection: The practice of gathering information about an electrical system by observing infrared radiation, recording findings, analyzing findings, and presenting that information. Exceptions: are abnormally warm components that may be a potential problem. Exceptions are usually identified by comparing the thermal patterns of like components.

Electrical Inspection Items Transformer Pad Mount Dry Overhead Service Entrance Main Switchgear Motor Control Centers Disconnects Bus Duct Distribution Panels Control Panels Rectifiers Drives Capacitor Banks Any Electrical Connection

Exception Analysis When should you repair this exception? Below is an exception. One of the conductor terminals is hot. Hot Terminal Temperature…..203F Left Terminal Temperature….156F Temperature difference is …… 47F When should you repair this exception?

Exception Repair Priority Criteria Temperature Difference 10F or Less No Corrective Measures Required At This Time. Priority 1 Temperature Difference 10F to 20F Corrective Measures Required At Next Maintenance Period Priority 2 Temperature Difference 20F to 30F Corrective Measures Required As Scheduling Permits Priority 3 Temperature Difference 30F to 100F Corrective Measures Required As Soon As Possible Priority 4 Temperature Difference Over 100F Corrective Measures Required Immediately

Exception Example #1 Breaker Connections Hot Spot Temperature…...203F Reference Temperature….156F Temperature Difference….47F Repair Priority 3 Corrective Measures Required As Soon As Possible

Exception Example #2 Fuse Block Hot Spot Temperature…...303F Reference Temperature….170F Temperature Difference….133F Repair Priority 4 Corrective Measures Required Immediately

Exception Example #3 Breaker Connections Hot Spot Temperature…...459F Reference Temperature…..101F Temperature Difference….358F Repair Priority 4 Corrective Measures Required Immediately

Exception Example #4 Main Switchboard Fused Switch Hot Spot Temperature...311F Reference Temperature..151F Temperature Difference...160F Repair Priority 4 Corrective Measures Required Immediately

Exception Example #5 Breaker Load Hot Spot Temperature….71F Reference Temperature…55F Temperature Difference..16F Repair Priority 0 No Corrective Measures Required At This Time Breaker Load A-105 amps B-150 amps C-167 amps

Exception Example #6 Building Service Drop Hot Spot Temperature...301F Reference Temperature…77F Temperature Difference..224F Ambient Temp………….45 F Repair Priority 4 Corrective Measures Required Immediately

Exception Example #7 Arrestor Pad Mount Transformer Hot Spot Temperature….92F Reference Temperature...58F Temperature Difference..32F Ambient Temperature….45F Repair Priority 3 Corrective Measures Required As Soon As Possible

Exception Example #9 Pad Mount Transformer High Side Hot Spot Temperature….159F Reference Temperature…98F Temperature Difference..61F Ambient Temperature….71F Repair Priority 3 Corrective Measures Required As Soon As Possible

Exception Example #10 Motor Drive End Bearing Hot Hot Spot Temperature….127F Reference Temperature…99F Temperature Difference..28F Ambient Temperature….74F Repair Priority ? Mechanical System

Thermal Picture Pad-Mount Cooling Fins In this case the exception is cold

Thermal Picture 480 Volt Capacitor Bank Again the exception is cool

Infrared Tips Use a Certified Thermographer Proper Training is vital to understand thermography Cost Effective - Quality Camera is $20,000 to $50,000 Scan should cost from $800 to $1500 per day Inspect When System Load Is High Useless To Scan Under Light or No Load Keep in mind that an infrared electrical inspection is only a report of the electrical system at the time of the inspection. Equipment that was off or unloaded because of cycling or scheduling may have problems that were not evident at the time of the inspection. Do Inspections On A Periodic Basis --Annually Good - Semi-Annually Better (at least first couple of times) Insures that over period of time all equipment is inspected

Benefit of Electrical Infrared Inspections "...From a return on investment perspective, infrared inspection programs have proven that on average for every $1 spent on infrared electrical inspections, there is a $4 return on investment for materials and labor from fixing the problems before it fails..." "Cost/Benefits Analysis of Infrared Programs." Maintenance Technology Magazine June 2001 $1.00 $4.00 =