Innovative Natural Gas Calorimeter GasCVD

Slides:



Advertisements
Similar presentations
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Advertisements

… for Combustible Gas Detection S4000C Intelligent Sensors..
Customer Service – International dept. STAR 24 3 E.
ICAM50x Series – Intrinsically Safe Digital Cameras Copyright Extronics Ltd iCAM50x Series Intrinsically Safe Digital Cameras for Hazardous Areas.
QuadMode SM Simultaneous Sampling. Reliable Performance & Innovative Features for Dependable Results  High performance – cc/min flow range.
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
Competition Other types of flow meters Thermal Mass flow competition.
Semiconductor Input Devices
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
UR24 Process Refractometer
| 1 © 2013 Universal Lighting Technologies ULT Marketing LED Product Capabilities.
How to increase energy efficiency? Evaldas Paliliūnas.
NeSSI AND ANALYZERS NeSSI AND ANALYZERS ISSUES AND DISCUSSION REGARDING THE SAM CONCEPT FROM THE ANALYZER SUPPLIERS PERSPECTIVE.
You Can Measure the Benefits… Training Course Introduction to SmartScan.
© ABB Group August 13, 2015 | Slide 1 Power Generation Service Life Cycle Management for Power Plants Daniel Looser, Power Gen Europe in Amsterdam, June.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
EESIFLO International Pte Ltd
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Smart transmitters.
E VERY L IFE H AS A P URPOSE… Ultima ® XL/XT Gas Monitors.
High Sensitivity Smoke Detection
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
What is TechStar … TechStar is a manufacturers representative dedicated to serving various Texas industries with process control instrumentation and analytics.
Automating Continuous Gas Lift
West Hills College Farm of the Future The Precision-Farming Guide for Agriculturalists Chapter Seven Variable Rate Technologies.
DataMaster 3000 Data Acquisition and Control Software.
The Theory of Near Light Scatter
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
1 Name | Confidential Date Center line content EXPLOSION-PROOF ENCLOSURE MARKET INTRODUCTION PRESENTATION.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
IN-SITU ANALIZA GASOVA
1 Gas Billing KRISS Kyung-Am Park. 2 KRISS Fluid Flow Group  High pressure gas flow Lower than 10,000 m3/h, 0.18% % 10,000 m3/h ~ ??,
1 Field Devices – Sales and Marketing Conference – April 2015 Field Devices 2014 BR - Confidential 1 Field Devices Foxboro® “S” Series Pressure April 2015.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
“The Industrial Workhorse”
1-Port Ultra PoE to 4-Port 802.3af/at Gigabit PoE Extender
AHR Expo 2014 Distributor Breakfast Meeting
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
The New C55* CPVSd 10-20hp People. Passion. Performance.
WELCOME TO ASHRAE 2011 LAS VEGAS DEALER BREAKFAST MEETING
Flow Group Smart Wireless
Black Carbon Burner An-Najah National University
USonic-R™ Remote 2-Channel System
How SCADA Systems Work?.
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
The FG series of explosive and toxic gas detectors and panels
The advantages of going wireless
SKC IS PROUD TO INTRODUCE A NEW LOW FLOW SAMPLING PUMP
Flow-X/C Flow Computer
HBLT-wire Product Introduction September 21, 2018.
Online Guidance is Available to Repair HP Scanner
F&J SPECIALTY PRODUCTS, INC.
Training Course SuperCool 1000 Level 1
R.Hermansson, J.Dahl, J.Lundgren, M.Lundqvist, G.Eriksson, B.Lundqvist
Customer Presentation
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Switching & Controlling LoB
Alabama Industrial Assessment Center
PowerLogic™ offer for the basic metering market
169 South Main Street, New City, NY 10956
Exp H2 Generator ATEX approved Hydrogen Generator
MULTI - DPG.
724 Temperature Calibrator
SCITEQ End closure series
Instruments & Electrical Measurements Lecture 4
Total Solution for Flue Gas Analyzer Series
Automobile Emission Gas Analysis Solution
Presentation transcript:

Innovative Natural Gas Calorimeter GasCVD Fumitaka Nozawa AAC Marketing Dept. Yamatake Corporation

Contents 1. APPLICATIONS 2. FEATURES 3. STANDARD SPECIFICATIONS 4. PROCESS GAS SPECIFICATIONS 5. MODEL NUMBERS

APPLICATIONS MAJOR TARGETS GasCVD is a custody transfer devise to realize fair deal under calorific value determining. Especially in Europe, a lot of inlets as to natural gas from Africa, Russia, and East and West Europe. The customers expect to realize fair deal by real time calorific value measurement. Main Pipe line Local pipe line Primary network for natural gas Megadeal customers ex. Power plants Pressure regulator Gas chromatgraphy with OIML R140 Secondary network for natural gas Flow meaurement GasCVD with OIML R140 End users

1. APLICATIONS THE OTHER POTENTIALS Combustion efficiency improvement for gas turbines Gas turbine manufacturers use gas chromatgraphs to measure gas composition for gas turbine. But gas chromatgraph needs a lot of time to analyze gas composition, the customers expect real time, fast response calorific value measurement to improve combustion efficiency. LNG satellites LNG satellites control gas calorie before providing the customers. A lot of calorimeters are used in the sites.

2. FEATURES (1) OIML R 140 and WELMEC compliant device (2) Innovative structure compatible with various installation sites (3) Revolutionary continuous measurement, and fast response (4) Automatic calibration for prolonged stability (5) A wealth of diagnostic functions

OIML R 140 and WELMEC compliant device Can be used as a calorimeter or calorific value determining device (OIML R140 CVDD) for natural gas.

(2) Innovative structure compatible with various installation sites • Unlike conventional gas calorimeters, GasCVD is innovative small and lightweight, allowing a variety of installation site choices. • Explosion-proof structure is compliant with IECEx and ATEX, and suitable for Zone 1 use.

(3) Revolutionary continuous measurement, and fast response Can detect a change of calorific value in processes in near real time by measuring every 2s. The time constant for 90 % response is within 30 seconds (sample flow rate: 50 ml/min) resulting in very fast output of natural gas calorific value.

Structure for revolutionary continuous measurement, and fast response TCD Sensor Gas flow

(4) Automatic calibration for prolonged stability Automatic calibration using pure methane guarantees long-term stable operation. Example for automatic calibration program

Example of recommended GasCVD installation for Automatic calibration

(5) A wealth of diagnostic functions • Ambient temperature diagnostic function. Determines whether the operating environment is suitable, making use of a temperature sensor embedded on the same chip as the thermal conductivity sensor. • Operation time tracker function. Keeps track of the total operation time for comparison with the recommended replacement period (70000 hours) for the calorimeter. • Automatic calibration history check function. Shows up to 5 of the latest automatic calibration records to check changes in the calibration factor. Menu for diagnostics in HART ver.7.0

3. STANDARD SPECIFICATIONS Process gas connection port: NPT 1/8 (F), Rc 1/8 Electrical conduit: NPT 1/2 (F), M20 Case structure: IEC IP66 Flame-proof structure: ATEX: II 2G Ex d II B T6 Gb;II 2D Ex tb IIIC T80 °C Db IECEx: Ex d IIB T6 Gb, Ex tb IIIC T80 °C Db Indicator: LCD Calorie display: 5 digits Units: SCV, MJ/m3 % display: setting range is shown by a % and by a bar graph Automatic calibration setting display: ●and ○ light up alternately when set. Calibration factor display: a flag is shown if calibration fails Communications: HART protocol ver. 7.0 Power: 24 Vdc ±10 %, 0.3 A max. (inrush current at startup) Output: Analog output 4–20 mAdc Contact output: 24 Vdc ±10 %, 50 mA max. (transistor contact for status) 24 Vdc ±10 %, 1 A max. (transistor contact for calibration)

Indicator

4. PROCESS GAS SPECIFICATIONS Natural gas (NG), in gas form only Temperature: –10 to 50 °C Pressure: 110 kPa (abs) max. (at GasCVD process connection port inlet) Flow rate: 50 ±10 ml/min Dust: Less than 1 μm in diameter, 1 mg/m3 max. Mist: none at –20 °C Moisture: dew-point temperature –20 °C max.

5. MODEL NUMBERS