PowerLogic™ offer for the basic metering market

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.

 UK Power Networks. All rights reserved Distribution Network Visibility Low Carbon Networks Fund Tier 1 project UK Power Networks & PPA Energy Omer.
Multi Functional Digital Fault Recorder
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
MODULAR SMPS POWER PLANT
LP33 Series UPS kVA 400Vac/CE
MTE´s Portable Product Portfolio
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
G GE Power Management MMII Intelligent MCC Controller.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
DCRK DIGITAL POWER FACTOR CONTROLLERS
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
PowerGUARD Energy Saving for inductive loads Saving 8%-15% Protection Power Quality.
DC POWER SUPPLY. Maeil Power Co.,Ltd is a one of leading supplier of switching power supply. The company design and manufacture quality products that.
MIG II DIGITAL FEEDER PROTECTION
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
CALPORT 300 Three-Phase Portable Reference Standard
PowerLogic® E5600 power and energy meter 1.
American Control Technologies,Inc Power Factor Correction Technology 1152 West 2400 South Suite ‘C’ Salt Lake City, Utah
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Looking for a more powerful circuit monitor?
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
FG Wilson Access 4000 Control Panel
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
PowerLogic® PowerView Software
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
Make the most of your energy December 2008 Multi-Circuit Meter Need to monitor multiple electrical services, which share a common voltage source? PowerLogic.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000.
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
EasyLogic PM2000 series The easy choice for quality, value, and simplicity. Customer overview.
PMC-592 HMI's Front Panel Operation
DIGITAL MULTIMETER DMG
POWER FACTOR CORRECTION
VARLOGIC NRC12 Varmetric Controller
C1300 advanced circular chart recorder
IP-based 8-port Switched Power Manager
POWER FACTOR CORRECTION
Avaya Online UPS 6000 VA.
New EM210_AV.
Portable Working Standard
Electric Machine Induction Motor
PTS 3.3 C Portable Test System.
LDA Large Display for Analog Inputs
FEEDER PROTECTION UNIT
The advantages of going wireless
Product Training Module
METER SPECIFICATIONS.
PQube vs. X (instrument from competitors)
Lesson 11: Transformer Name Plate Data and Connections
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Integrated gateway-server
Introduction to the POWERLOGIC® PM700 Series Power Meters
PowerLogic PM5350 High-performance multifunction power meter
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
PM9, PM9P and PM9C Power Meter
Meet demanding customer expectations with the right energy meter
PowerLogic ION6200 Power and energy meter.
Simple, accurate tenant sub-metering
Power monitoring software
Presentation transcript:

PowerLogic™ offer for the basic metering market PowerLogic DM6000 series digital panel meters PowerLogic PM1000 series multifunction power meters

Offer overview for basic metering market Schneider Electric’s PowerLogic offer for the basic metering market provides quality devices you can trust with features that meet your needs, all at an affordable price!

Offer overview for basic metering market DM6000 series meters Digital panel meters, or VAF meters Basic parameters (volts, amps, power factor and frequency) Ideal for replacing multiple analog meters with a single digital meter to simplify wiring, save panel space and reduce installation labour costs PM1000 series meters Entry-range multifunction meter Basic parameters, energy parameters, power parameters, demand and total harmonics distortions Ideal for energy and power monitoring of your electric system’s essential measurements Does everything the DM6000 series can do and more!

Typical applications for each series DM6000 series PM1000 series Direct replacement of existing analog meters in a single panel One voltmeter with one selector switch, or three or six voltmeters One ammeter with one selector switch, or three ammeters Frequency meter PF meter RPM meter (wherever required) Equipment monitoring Preventive maintenance scheduling Equipment monitoring Preventive maintenance scheduling Energy monitoring Power monitoring Demand monitoring Load studies and circuit optimization Energy balancing Energy optimization

Two meter models per series PowerLogic DM6000 series models DM6000 – basic without communications DM6200 – basic plus 2 terminal RS-485 port with Modbus RTU protocol PowerLogic PM1000 series models PM1000 – basic without communications PM1200 – basic plus 2 terminal RS-485 port with Modbus RTU protocol

Easy to install, easy to use Easy installation and configuration Color-coded terminal board label to help ensure accurate wiring Direct connection for metering voltage inputs up to 480 V ac L-L Programmable CT ratios (primary and secondary) Fully site programmable for various configurations using front panel buttons Easy to use Large front panel buttons Quick access to most commonly viewed parameters or enter set up mode with a single push of the Turbo Key button Turbo Key

Easy to read, secure information Efficient display Bright, 3-measurement LED display Large 15 mm alphanumeric characters Auto-scaling of values from kilo to mega to giga Auto scrolling from parameter to parameter, page to page Analog load bar Secure Rugged construction A unique password protects the setup menu and default page settings Analog load bar

Measured parameters Parameters common to both DM6000 series and PM1000 series Volts: phase to phase average, per phase phase to neutral average, per phase Amps: Per phase and average, neutral amps Power Factor (PF): Per phase and average Frequency RPM % Loading (Amps) % Unbalance (Volts and Amps) Load bar: % loading Full Scale Phase Angles: Amps per phase On Hours Number of Interruptions

Measured parameters continued Additional parameters for PM1000 only Power: active, reactive, apparent (per phase and total) Energy: active, reactive (Inductive and Capacitive), apparent Energy: total, import, export Demand: Present demand and maximum demand (Amps, KW, or KVA) Time remaining Demand: sliding window or fixed window Period user programmable with 5 minute intervals Total Harmonic Distortion: % THD (volts and amps) per phase Run Hrs

Accuracy ratings Both DM6000 series and PM1000 series meters Volts, Amps, PF: 1.0 % of reading PM1000 series meters only Energy Active: 1.0 as per IEC 62053-21 Reactive: 2.0 as per IEC 62053-23 Apparent: 1.0 % of reading Power Active: 1.0 % of reading Reactive: 2.0 % of reading

Common specifications for both series Size: 96x96 mm bezel, 92x92 mm panel cut out Data Update: 1 second Input Voltage: 80 – 480 V ac L-L without PTs; up to 999 kV with PTs Input Current: Through CTs CT primary: 1 A – 99.0 kA, CT secondary: 1 A – 5 A Burden: 0.2 VA per phase, 3 VA on power supply Power Supply: 44 – 277 V ac / dc Temperature: Operating: - 10° to +60° C Storage: - 25° to +70° C IP Rating: Front: IP 51, Back: IP 40

Standards compliance Both DM6000 series & PM1000 series meters UL 508 compliant Emission as per CISPR 22 ESD (electrostatic discharges) per IEC 61000-4-2 Electromagnetic RF fields per IEC 61000-4-3 Electrical fast transient per IEC 61000-4-4 Surge immunity test per IEC 61000-4-5 Conducted disturbance induced by RF fields per IEC 61000-4-6 Damped oscillatory wave per IEC 61000-4-12 Impulse voltage withstand 6kV for 1.2/50µS per IEC 60060-1 REACH compliance

For more detailed information on this product, or other products, services and solutions Ask your Schneider Electric representative Visit www.schneider-electric.com/