R200 and ATS100 Presentation 01/12/2013.

Slides:



Advertisements
Similar presentations
Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Advertisements

Square D Electrical Protection And Monitoring
ZXM10 EISU Training.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
Premset : A New generation of MV Switchgear
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
Substation Automation (S.A) System Project Supervisor: Stuart Wildy.
OVERVIEW TBOX The best of 3 worlds.... TBOX The best of 3 worlds...  best of Automation  best of Internet  best of Telemetry.
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
IRRInet & ICC System Concept
Electrical Distribution Training
April 2011 November 2010.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
Medium Voltage products Energy reliability & revenue improvement Speaker: Jean-Yves Pocthier - Schneider Electric France Technical solution for improvement.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
SmartMQn Motor Horner APG, LLC September 9, 2008.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
Distribution Automation The utilization of IEDs (Intelligent Electronic Devices) and advanced communications to unlock the benefits of operational efficiency.
Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000.
SCADA Supervisory Control And Data Acquisition Pantech Solutions Here is the key to learn more.
Advanced Datalogger: Z-GPRS3. # 4 Digital Input PNP, NPN bit max 30 Hz) RAM and Flash RAM 256 KB 1 MB + 8 MB (log) SD card max 32 GB.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
Configuring Network Devices
DIGITAL MULTIMETER DMG
Poseidon 4002 Rack monitoring.
CMV-NET Chigo VRF Network Centralized Control System
SCADA SCADA TRAINING AJAY K BASU
VARLOGIC NRC12 Varmetric Controller
L14 - Speed Integration with Ethernet-enabled CENTERLINE® MCCs, Rockwell Software Studio 5000® and IntelliCENTER® Software.
IP-based 8-port Switched Power Manager
GammaTRACER Key features
Maintain, Manage And Monitor Outdoor Systems Remotely
How SCADA Systems Work?.
A transformer is a complex protective object
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
LCD Network Monitor.
Distribution Automation
Solar Village Retrofit 1 of 4
PowerValue 11/31 T Sales Presentation
Peter Erning, PSP-T11, Power Gen 2010
Sunnytek sensor networks
TB8100 Technical Training July 2005
Protection Philosophy
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
ABB SACE Emax 2 ANSI C37 / UL1066 Concept Global Product Management
Friday, December 28, 2018 ABB SACE Emax 2 Concept
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
IRRInet-M IRRInet-ACE Product Introduction
Substation Automation System
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Moxa Embedded Solution on IEC 61850
Ethernet Gateway EGX200 - EGX400
Switching & Controlling LoB
Integrated gateway-server
PowerLogic™ offer for the basic metering market
energy revenue & power quality meter
PM9, PM9P and PM9C Power Meter
PowerLogic ION6200 Power and energy meter.
Field installable, upgradeable and scaleable
Backup Power supply for Electrical substations Overview 01/2012
Power monitoring software
Presentation transcript:

R200 and ATS100 Presentation 01/12/2013

Easergy R200 and ATS100 Control and Monitoring distributed system All the power and experience of Easergy range now inside Premset

The new generation of switchgear technology Premset: a disruptive technological breakthrough opening to a new generation of switchgear - Efficiency Smart grid and advanced management solutions across the network Intelligent, smart grid-ready solutions: - Feeder automation - Load management - Asset management - Automatic Transfer System Architecture with distributed intelligence Premset The new generation of switchgear technology The new generation of switchgear technology also means embedding the smart devices directly inside the switchgear Schneider Electric UK Medium Voltage Activity 10/02 Product Marketing

R200 and ATS100 System

Premset Control & Monitoring

Embedded intelligence in switchgear Local SCADA DMS LAN WAN Ethernet Modbus IP, IEC870-5-104, DNP3 IP RTU, ATS Power Supply Modbus Serial and IP IEC870-5-101/104 DNP3 Serial and IP PSTN RS232/485 Radio (FFSK) GSM / GPRS 3G R200 or ATS100 PS100 Modbus RS485 SC110 Flair 23DM PM800 VIP410 Energy Quality Monitoring Switch Controller FPI & Voltage presence Self powered Protection

System functional summary Controls and monitors MV switchgears: SC1x0 (up to 29) Detects the passage of fault currents: Flair 2xD: All earthing systems Detects Voltage presence/absence: VD23: Highly configurable Measures: Current, voltage, power, energy, .... : PM Protection relays : VIP or SEPAM Automated network reconfiguration: ATS 100: ACO or BTA Supplied by a High availability Power Supply and battery: PS100 Configuration and Diagnostic tool through Web server Communicates to DMS and/or local SCADA Can integrate other Modbus slaves NEW!

Embedded intelligence in switchgear Functional approach based on optional and independent modules to cover various combination and offer just enough architecture Remote Communication:R200 or Source transfer: ATS100 Modules fully integrated in functional unit Including sensors, switchgear interface, power supply, communication, HMI Pre- engineered, factory-tested, cost effective Easy integration based on : Field bus communication between modules Pre-cabling inside cublicle Other Modbus slave devices can be integrated: Sepam 80, PM, Ion meters, etc... Modbus Power supply : PS100 Fault passage indication : Flair 23DM Protection : VIP410, Sepam 20 or Sepam 40 Switchgear Control : SC110A or SC100E Voltage detection : VD 23 Power Monitoring : PM 800

Catalogue R200/ATS100 system Stand alone R200 ATS100 SC1x0 Flair 2xD 6 references, according to communication medium R200 Remote com. Remote com. + Source transfer 6 refs: ACO or Bus Tie, and no modem, GPRS or 3G ATS100 SC1x0 Local/remote control SC100A: 24-60 Vdc SC100E: 110-250Vdc 120-240Vac SC110A: 24-60 Vdc SC110E: 110-250Vdc 120-240Vac Flair 21D: Supercap Flair 22D: Li battery Flair 23D: Ext Vdc Flair 23DM: FPI + Voltage relay + Modbus communication Flair 2xD Fault passage indicator Voltage detection relay VD23 Voltage detection relay VD23 Flair 23DM: FPI + VIP410A VIP410E Self powered protection relay VIP400 VIP40/45 VIP 4 PS100 24VDC PS100 48VDC PS100 Power supply Sepam Auxilliary powered protection relay Sepam 20, 40, 60, 80 PM Energy Monitoring PM800

Easergy R200/ATS100 Common Functions

Substation Monitoring Data acquisition from local devices Fault detection: Flair Protection relays trip indication Cubicles status Voltage presence: VD23 Measurement: Power Meter: I, U, power, energy, Concentrator of other Modbus slaves: Time stamping Clock synchronisation through DNP3 or IEC protocol or Ethernet Date stamping discrepancy: 20 ms Monitoring digital and analogue variables Managing alarms or simple recording: thresholds, dead band, ... Configurable recording settings Archival capacity: Event Log 10000 Alarm Log 2000 Measurement log 50000 System Log 6000

SCADA Communication NEW! Compatible with all SCADA Systems Catalogue of protocols including the major standards with IP versions IEC 870-5-101 and 104 DNP 3 level 3 serial and TCP/IP MODBUS serial and TCP/IP Compatible with all communication media A large catalogue of built-in modems: RS232/485, radio (FFSK), PSTN V32, Ethernet, GSM/GPRS/3G The RS232/RS485 interface can handle external modems SMS, Mail One “modem” port + one Ethernet port NEW!

Standby supplies high availability Guaranteed Switchgear Operation An energy Battery and charger sized to supply Motor drive systems: 24 or 48 VDC Transmission equipment: 12VDC, 1A permanent, 7 A peak Substation equipments Total max power 90W permanent Guaranteed long battery life A regulated and temperature compensated charger Protection against total discharging Schematic with external relays proposed for long duration outages Guaranteed power supply availability Continuous power supply self-checking Typical autonomy: 16 hours with 10 O/C cycles Alarm returned if fault occurs Battery service life at 20°C: 10 years

A powerful configuration tool 2 major new features for better efficiency and productivity Off-line configurator: Same Web pages can run locally on the PC or on the R200/ATS100 Modbus slaves auto discovery with predefined configuration files NEW! NEW!

Easy to setup Easy&Quick System Configuration Scan 1 2 3 4 ON T/R ATS 100 1 2 NEW! Data In order to make commissioning an easy, straight forward, and therefore fast task, R200 and ATS100 are fitted with features new to the Easergy range: User can activate a scan of the Modbus slaves that will automatically detect all slaves connected and the associated default configuration and data (Of course, this applies only to Modbus slaves part of the system). User tasks is therefore finally limited to configuring each of the devices according to his application needs as well as configure R200 specific configuration parameters such as communication to SCADA Scan & Modbus slaves auto-discovering Display the single line diagram Display each device data Configure each device according to application and R200 (communication etc...)

Powerful diagnostic and alarm through Web pages simplicity Powerfull diagnostic and alarm through Web pages Data view Single line System view Alarming

A whole system for control and monitoring 32 devices max Daisy chaining of smart modules Self configuration Automatic Modbus configuration Automatic module detection and configuration Sensors, HMI, devices integrated in cubicle One power supply for the whole switchboard See each product presentation (SC100, PS100, Flair 2xd, etc…) for more details)

Easergy ATS100 Specific Functions

ATS100 Features Module dedicated to source change over Main functions Inherits from all R200 functions Own box + dedicated interface Only field bus interface with the switchgear Main functions Automatic source change over (lines, bus tie) Safe manual operation With or without // coupling Remote communication (Ethernet, 2G, 3G)

ATS100 Architecture Auxiliary supply provided by PS100 SC110 SC110 Auxiliary supply provided by PS100 ATS100 : 12V or 24 or 48V SC110, Flair 23DM, motorisation : 24 or 48V

ATS- ACO : 1/2 - 2 lines

ATS-BTA : 2/3 - 2 lines + bus tie Bus tie normally open

Dedicated HMI (2/3) Local /remote On / Off Automatic change over Behaviour Auto return (no predefined normal source) No return (keep on back-up source after change over) Self return (back on normal source possible after change over) Manual operation Sequenced operation on switchgear

Dedicated HMI (3/3) Reset automation (Unlock) LED and communication test (SCADA and system)