Data quality of inorganic compounds in air and precipitation

Slides:



Advertisements
Similar presentations
A EUROPEAN AEROSOL PHENOMENOLOGY: TOTAL CARBON, ELEMENTAL CARBON AND ABSORPTION COEFFICIENT Fabrizia Cavalli European Commission – DG Joint Research Centre.
Advertisements

PM 2.5 Carbon Measurements in EPA Region 10 Robert Kotchenruther, Ph.D. NW-AIRQUEST June, 2011.
What are the important parameters that need to be defined for a carbonaceous aerosol analysis ? Hélène CACHIER Laboratoire des Sciences du Climat et de.
Example Conceptual Models for Organic Sampling Artifacts on Quartz Fiber Filter Prepared by Marc Pitchford for the IMPROVE/CSN Carbon Monitoring Workshop.
Carbon artifact adjustments for the IMPROVE and CSN speciated particulate networks Mark Green, Judith Chow, John Watson Desert Research Institute Ann Dillner.
1 Policies for Addressing PM2.5 Precursor Emissions Rich Damberg EPA Office of Air Quality Planning and Standards June 20, 2007.
EPA PM2.5 Modeling Guidance for Attainment Demonstrations Brian Timin EPA/OAQPS February 20, 2007.
Using field campaigns results to reduce uncertainties in inventories Wenche Aas, Knut Breivik and Karl Espen Yttri And material from: Eiko Nemitz (CEH,
Carbon Measurements and Adjustments Measurement of organics by IMPROVE & STN networks, Use of blank data to correct carbon concentration measurements,
Section highlights Organic Aerosol and Field Studies.
Air Quality Impacts from Prescribed Burning Karsten Baumann, PhD. Polly Gustafson.
VII. How might current analysis methods be enhanced or combined to obtain more information about the nature of OC, EC, and other carbon fractions in filter.
Intensive measurements and modelling of size segregated chemical composition of aerosols in June 2006 and Jan 2007 Wenche Aas, Rami Alfarra, Elke Bieber,
Developments in EMEP monitoring strategy and recommendations from AirMonTech Kjetil Tørseth, NILU/EMEP-CCC.
/tfmm3 EMEP Chemical Coordinating Centre Measurements of particulate matter in EMEP Current implementation Kjetil Tørseth, Wenche Aas, Michael.
EMEP INTENSIVE MEASUREMENT PERIODS IN CLOSE PARTNERSSHIP WITH EU PROJECTS Wenche Aas, Andres Alastuey, Francesco Canonaco, Fabrizia Cavalli, Franco Lucarelli,
Relevant activities in EMEP Wenche Aas EMEP/CCC (NILU) EMEP Monitoring programme Expansion to the EECCA region, HTAP QA/QC.
Uncertainties in atmospheric observations Wenche Aas EMEP/CCC.
1 Saxony-Anhalt State Environmental Protection Agency Wolfgang Garche Bukarest EU-Twinning Project RO 2006 IB EN 09 Wolfgang Garche Saxony-Anhalt.
25/05/20071 About comparability of measured and modeled metrics Jean-Philippe Putaud Fabrizia Cavalli DG JRC Institute for Environment and Sustainability.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Synergies between EMEP and EUSAAR Wenche Aas and Kjetil Tørseth EMEP/CCC (NILU)
Online measurements of chemical composition and size distribution of submicron aerosol particles in east Baltic region Inga Rimšelytė Institute of Physics.
EMEP Monitoring programme Wenche Aas EMEP/CCC (NILU)
Model Evaluation Comparing Model Output to Ambient Data Christian Seigneur AER San Ramon, California.
Regional Air Quality Modeling Results for Elemental and Organic Carbon John Vimont, National Park Service WRAP Fire, Carbon, and Dust Workshop Sacramento,
EMEP Monitoring Strategy Status and challenges, with main focus on the EECCA region Wenche Aas and Kjetil Tørseth EMEP/CCC (NILU)
ENEON first workshop Observing Europe: Networking the Earth Observation Networks in Europe September, Paris [EMEP,ACTRIS,HELCOM,CAMP and more/NILU]
2016 TFEIP meeting, Zagreb, 16-18th May 2016 Cross-cutting WG TFMM-TFEIP on SVOC emissions Working document for the workshop on condensables & Semi-Volatiles.
Atmospheric Sciences Research Center University at Albany QA/SAC for the Americas World Data Centre for Precipitation Chemistry QA/SAC of the Americas.
Air Quality in EEA and EECCA Europe’s Environment assessment report, th Europe’s Environment assessment report, 2007 (‘the Belgrade report’) Hans.
Testing & Comparing Stoves
World Health Organization
Extended Bureaux EMEP & WGE, Geneva March 21th 2017
Bob Cary and David Smith
Dr. Tanveer Iqbal Associate Professor,
Svetlana Tsyro, David Simpson, Leonor Tarrason
Calibration in the Ambient Air Quality Monitoring Network
Contribution from AQUILA to Air Policy Review
Svetlana Tsyro, David Simpson, Leonor Tarrasón
EMEP intensive measurements, June 2006 and Jan 2007
Wenche Aas and Karl Espen Yttri (EMEP/CCC)
ACTRIS Aerosol Chemical Speciation Monitor (ACSM) Network and new filter off-line techniques to measure PM chemical composition and determine organic aerosol.
A Review of Time Integrated PM2.5 Monitoring Data in the United States
John Munthe and Ingvar Wängberg
Progress on sampling and analysis of carbonaceous aerosols:
EMEP Monitoring Strategy
Status of data from EMEP intensive period 2008/2009
Monitoring strategy, technical issues
Results of the inter-laboratory exercise for TC, OC and EC measurement OCEC Fabrizia Cavalli and Jean-Philippe Putaud.
About comparability of measured and modeled metrics
Rationalizing the differences between thermo-optical OC/EC methods.
Reporting QA Measures to EBAS – and a Word on Flagging
Uncertainties in atmospheric observations
Longer Term Aerosol Chemical speciation monitoring data during ACTRIS/EMEP activities ACSM Teams across Europe Many slides from Michael Bressi, JRC Italy.
EUSAAR contribution to the EMEP intensive field campaigns
Jean-Philippe Putaud, Fabrizia Cavalli
DETERMINATION OF CARBONATE CARBON
Wenche Aas, Kjetil Tørseth, Cathrine Lund Myhre
Introduction – workshop on EBAS and Data Quality
Lessons learnt from the EMEP intensive measurements
Summary: TFMM trends analysis
UK (CEH) and ACTRIS WP3: In-situ chemical, physical and optical properties of aerosols WP4: Trace gases networking: Volatile organic carbon and nitrogen.
Wenche Aas Status of EMEP measurements today Field intercomparison
DRAFT GAW/WMO SAG – AEROSOL
Welcome TFMM workshop on the implementation of the EMEP monitoring strategy Introduction to the monitoring strategy QA/QC activities of EMEP organisation.
EC/OC – monitoring within EMEP
Benefits of ACTRIS for Implementation of EMEP monitoring strategy
Svetlana Tsyro, David Simpson, Leonor Tarrason
Quality assurance and data quality in relation to trend assessments in EMEP Kjetil Tørseth, Wenche Aas and Jan Schaug Documenting changes in atmospheric.
Presentation transcript:

Data quality of inorganic compounds in air and precipitation Wenche Aas

Relevant topics to discus Status of the program Coverage and methods used (reference method?) Quality Documentation of the data quality Revision of Data quality objectives (DQO) ? Common problems/challenges

Methods used and problems with comparability in time and space Manual methods in air and aerosols: EMEP. Filterpack with no size cutof and includes sumN EU Air quality directive: PM2.5, CEN standard EN 16913:2016 Contuinious methods more frequantly used: i.e. ToF- and Q-ACSM and MARGA

Challenges for the development of measurements in precipitation Sampling frequency Daily recommend Many use weekly and even biweekly and monthly Bulk contra wet only Storage –especially an issue in warmer areas Lack of parallel official rain gauge

Methods and sampling frequency, EMEP sites in 2014

Lab intercomparisons annually Per cent dev. from expected value > DQO > 2x DQO Per cent relative bias

Trends in lab performance (e.g SO4) The present DQO level

Data quality objectives inorganic 10% accuracy or better for oxidized sulfur and oxidized nitrogen in single analysis in the laboratory 15% accuracy or better for other components in the laboratory 0.1 units for pH 15-25% uncertainty for the combined sampling and chemical analysis (components to be specified later) 90% data completeness of the daily values The DQOs do not necessarily reflect the present need for accuracy If there a need to update the DQO, how to set the target? Based on the possibility to detect trends Based on how well the labs can perform

QA measures based on lab int results shall be reported with the data In the template: Annual data reporting should include results from two lab intercomparisons, which both cover part of the year. Download results from here: http://www.nilu.no/projects/ccc/intercomparison/qameasure/

Other things important to include when reporting Detection limit / quantification limit ? Details on instrumentation Filter choice and sample preparation (Ambient or not) Method uncertainty?? If yes –how to calculate this GUM test?

Results from last 5 years as base for new DQO (pass / no pass) ?? 10% 5%

Discussion point for this session How to avoid Parties to measure in accordance to the EU Directive only, at EMEP sites? How to ensure sufficient sampling frequency Specific challenges with the measurements ? Choice of filters (i.e. contamination of Pall Zefluour) Other things? DQO and QA measure

Data quality of ozone and nitrogen oxides Wenche Aas

Relevant topics to discus New guidelines and recomnmendations SOP developed in WMO/GAW and ACTRIS Methods (Nox monitor vs manual method) Documentation of the data quality New metadata included in the templates QA measures Common problems/challenges

Ozone, Status of DQ in the network The UV absorption method is the only measurement method in use. Good coverage For comparability in time and space. Question regarding representativity Calibration frequenzy General maintainance

Ozone, points to note Mixing ratio given as [nmol/mol] is the preferred unit Check Absorption cross-section Include information of monitor calibration(s) Include information on filter test, leak tests, ozone scrubber test etc in the "Maintenance description" element Include information of any kind if drying in the Temperature/humidity control tab. Data capture > 66% in accordance to SOP GAW (new flag?)

Calibration. EMPA –WCC Audits QA procedures can either refer to either (or both) WCC Empa audit calibrations using a laboratory standard traceable to a national standard

Methods used for NO2 and Nox

New reference method in EMEP Now: manual glass sinter Though many use chemiluminescence_molybdenum (note change in instrument_name) Change reference to chemiluminescence_photolytic GAW reference method is being develop (soon to be published)

Briefly on OC/EC measurements within EMEP Karl Espen Yttri

The EMEP EC/OC measurement campaign Carbonaceous Aerosol Observations in EMEP - Snapshots Spatial variability: Continental Europe 3x higher than North and North/West Europe, on average Ispra (IT) 10x higher than Birkenes (NO) (EC) Seasonal variability: Winter time concentrations higher than during summer for all but the Nordic sites wrt OC Relative contribution: 27 ± 9% of PM10 attributed to organic matter (OM) (OM = OC x 1.4-1.8) OM > SO42− for sites reporting both parameters 3.4 ± 1.0% of PM10 attributed to EC Lower Higher The EMEP EC/OC measurement campaign (2002 – 2003) (Yttri et al., ACP, 7, 5711–5725, 2007)

Carbonaceous Aerosol Observations in EMEP - Snapshots Figure 2: Ambient aerosol concentrations of OC in PM10, PM2.5 and PM10-2.5, and EC in PM10 and PM2.5 presented as weekly (168 h) mean concentrations for the Birkenes Atmospheric Observatory during the period 2001 – 2014. The black line is the running 10-week mean. EMEP sites reporting OC/EC in 2014 Regions of poor coverage are emphasized Yttri et al., in preparation

OC and EC - Operational defined Carbonaceous aerosol originate from a vast number of anthropogenic and biogenic sources, such as: Vehicular tailpipe emissions Domestic heating emissions Industrial emissions SOA from oxidation of anthropogenic and biogenic volatile precursor gases Primary biologial aerosol particles Only a limited fraction of the carbonaceous aerosol mass is identified on a molecular level Bulk carbonacoues fractions needed Operational definitions - TOA: OC - Organic Carbon EC - Elemental Carbon Proposed structure for hexane soot (Akhter et al., 1985)

Major development criteria for EUSAAR-2 EMEP recommends the EUSAAR-2 protocol for OC/EC measurements EUSAAR-2 elected as candidate for CEN standard summer 2015. Official vote by national representatives going on these days Standard operating procedure for OC/EC measurements to be found in the EMEP manual: 4.22 Standard Operating Procedures for thermal-optical analysis of atmospheric particulate organic and elemental carbon (http://www.nilu.no/projects/ccc/manual/index.html) Major development criteria for EUSAAR-2 Reduce charring WHY: Difference in α for PC and EC will affect the accuracy of the optical correction and thus the OC/EC split HOW: Increased duration and lower temperature at initial steps Complete evolution of OC in He-mode WHY: To avoid carry over of OC to the He/O2 – mode, and to prevent LAC EC evolving in the He-mode HOW: Max temp in He-mode = 650 °C appears as the best compromise Ambient aerosol filter sample measured by EUSAAR-2. Cavalli et al., 2010

Influence by CO32- - Carbon (CC) on OC/EC analysis CO32- - carbon influence on TOA by EUSAAR-2 CC likely vary from negligible (e.g. Scandinavia) to noticeable (e.g. the Mediterranean ) within the EMEP domain Potential overestimation of OC and EC if CC is not accounted for Whether CC evolves as part of the OC or the EC fraction, or both, depends on the actual protocol (e.g. EUSAAR-2; IMPROVE; NIOSH) used Currently no recommendation in the EMEP manual on how to account for CO32- - carbon influence on TOA Methods applied: Acidification Thermal-Oxidative pretreatment EMEP Status Report, 2015

NB: negative artefacts not accounted for! Collection of filter samples for subsequent OC/EC analysis Positive artefacts: Organic vapor phase components adsorb onto the filter/aerosol particles impacted on the filter Negative artefacts: SVOC condensed onto aerosol particles trapped by the filter that evaporate during continued sampling Tandem filter sampling - QBQ OCp OCg OCg Accounting for sampling artefacts Tandem filter sampling – QBQ OCParticulate = OCFront f. – OCBackup f. Positive artefact = OC on backup filter NB: negative artefacts not accounted for! Denuder OCParticulate = OCFront f. + OCneg. – OCpos. Positive artefact = OCFront f. * (1 - Denuder eff.) Negative artefact = OC on backup filter NB: Denuder efficiency and negative artefact are default values based on results from tests Front filter Front filter Backup filter Backup filter

Status of reporting - 2014 30 sites in 14 countries reported OC/EC data to EBAS for 2014 Eastern and western parts of the EMEP domain are poorly covered OC/EC measurements are performed that are not reported to EBAS Only two sites have a time-series that extend 10 years or more Shift in analytical protocol for both

Status of reporting – 2014 II All sites reported OC/EC data obained by TOA 28/30 reported data based on the EUSAAR-2 protocol EUSAAR-2 is likely becomming the CEN standard for OC/EC T (-93 - +100) Calibration of Temperatur-steps in your TOA instrument: HIGHLY IMPORTANT!!!!

Status of reporting III Ispra Aspvreten Vavihill 3/30 sites account for both pos. and neg. sampling artefacts Estimates of pos. sampling artefact exist for several sites (e.g. EIMPS). Should be made available via the submission template Yttri et al., (in prep.) OC/EC data quality has improved wrt sampling-time and frequency 61% of the sites did not use data quality flags; 0.999 and 0.000 excluded 30% reported OC/EC data according to the EUSAAR format 35% of the sites have a sampling scheme that covers < 75% of the year

Format Issues – A selection Copy and paste from the format is never a good idea! 2) Uncertainty: Calculate the uncertainties of your analyses! http://ebas-submit.nilu.no/Submit-Data/Regular-Annual-Data-Reporting/EC-OC 3) Unit: The unit is µg C m-3, not µg m-3. 4) Matrix (e.g. PM10, PM2.5 or PM1) must be combined with an appropriate Inlet type (e.g. direct impactor), not hat or hood implying a TSP inlet. 5) Filter face velocity: When calculating the ffv, use the exposed area, not the total area of the filter

Format Issues – A selection II 6) Filter pre-firing: Temperatures in Kelvin; duration of pre-firing to be included K 7) Artefact correction description: Describe how you correct for artefacts and how you calculate corrected values for OC (OCp) Description: Tandem filter sampling by QBQ Calculating OCp: OCp = OCFront filter – OCBackup filter 8) Detection limit: LOD can be different for TC, OC and EC; there is an option to also include the LOD along with the name of the variable

Format Issues – A selection III 9) Detection limit description: LOD often calculated as 3*SD of the fieldblanks; which might be challenging OC: To what extent are field blanks representative? EC: Field blanks do not contain EC !!! Important to use this section !!! Describe how the fieldblanks were obtained, e.g. if they have been inserted into the sampler and ran for e.g. 1 – 2 minutes.

Format Issues – A selection IV 10) QA - Measures ILC for EMEP sites performing OC/EC measurements is conducted as part of the EU-funded project ACTRIS-2 Time schedule for upcoming ILC on the following page: http://www.actris-ecac.eu/time-schedule.php The application procedure is thoroughly described on the following page: http://www.actris-ecac.eu/application-procedure.php Results from ILC to be included under QA

Heavy Metals and POPs

Heavy metals –discussion itemes QA measure and DQO Now based on low and high concentration samples. High , not realistic level in the network Change intercalibration to 4 samples with similar level (as for inorg) representative for the EMEP network and calculate QA bias and variability in similor fashion Field blanks Correction and actions taken when high blanks?

Mercury reporting Component names presently a mess elemental_gaseous_mercury   total_gaseous_mercury             gaseous_methyl_mercury                     reactive_mercury                                       reactive_gaseous_mercury I nedbør:  mercury  and methyl_mercury Simplify to only mercury (includes both TGM and GEM) Gaseous oxidized mercury (RGM, GOM) Methyl mercury Differentiate between TGM and GEM with metadata (with or withour sodalime) Quality difficult to assess Some labs with detection limit problem Include more information on how instrument is treated and ca valibration

POP –new metadata information Metadata Sample preparation (extraction+solvent+internal std+cleanup): Soxhlet+Dichloromethane+13C+Silica Soxhlet+Dichloromethane+No+Silica Soxhlet+Dichloromethane+13C+Silica/acid Soxhlet+Dichloromethane+No+Silica/acid Soxhlet+Di-ethyl ether/Hexane+13C+Silica Soxhlet+Di-ethyl ether/Hexane+No+Silica/acid Soxhlet+Hexane+13C+Silica Soxhlet+Hexane+No+Silica Ultrasonication+ Di-ethyl ether/Hexane+13C+Silica Ultrasonication+ Di-ethyl ether/Hexane+No+Silica microwave metadata medium Quartz+PUF Quartz+PUF+PUF Quartz+PUF+XAD+PUF Glass fiber+PUF Glass fiber+PUF+PUF Glass fiber+PUF+ XAD+PUF Teflon+PUF+XAD+PUF