SYNCHRONOUS MACHINES.

Slides:



Advertisements
Similar presentations
CE ELECTRICAL PRINCIPLES STEADY STATE ANALYSIS OF SINGLE PHASE CIRCUITS UNDER SINUSOIDAL EXCITATION 1 Steady State response of Pure R,L and C &
Advertisements

ENERGY CONVERSION ONE (Course 25741)
Chapter 4 Synchronous Generators Part II
Synchronous Machines (AC Generators)
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX ……SYNCHRONOUS MOTORS.
Power System Fundamentals
Chapter 4 Synchronous Generators
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
Synchronous Machines.
Three-Phase AC machines
SYNCHRONOUS GENERATORS
ENERGY CONVERSION ONE (Course 25741) CHAPTER FIVE SYNCHRONOUS GENERATOR- CAPBILITY CURVE.
AC Machines 6077SA NUE 046.
Synchronous Motors and Generators
SEE 3433 MESIN ELEKTRIK SYNCHRONOUS MACHINES Basic principles.
Lesson 37 AC Generators II
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Transformers.
Synchronous Generator
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
Synchronous Motors When a synchronous machine is used as a motor, it is not self-starting. If the rotor field poles are excited by the field current and.
Three-Phase AC machines
Example 1 A 9375 kVA, 13,800 kV, 60 Hz, two pole, Y-connected synchronous generator is delivering rated current at rated voltage and unity PF. Find the.
Department of Electrical and Computer Engineering
Motor ELECTRICAL ENERGY Mechanical Energy.
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX (& S.G. parallel op. with Pow. Sys. of chapter 5) SYNCHRONOUS MOTORS.
5.4 Circuit Analysis Using Phasors and Complex Impedances
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Fourth Edition, by Allan R. Hambley, ©2008 Pearson Education, Inc. Lecture 16 Phasor Circuits, AC.
Synchronous Induction
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX …. Synchronous Motor Starting.
AC POWER ANALYSIS Instantaneous & Average Power
Lecture 32Electro Mechanical System1 Assignment 9 Page 373 Problems 16-13, 16-16, and Due Date: Tuesday 19 th April, 2011 Quiz No.5 Next Week Quiz.
Lecture 32Electro Mechanical System1 Synchronous Reactance  The value of X S can be determined by measurements of the open-circuit and short-circuit tests.
Power System Fundamentals EE 317 Lecture 9 27 October 2010.
Chapter 17: Synchronous Motor
Power Factor Improvement Lecture 9. Normally, the power factor of the whole load on a large generating station is in the region of 0·8 to 0·9. However,
Chapter 5. Synchronous Machines.
EET 221 Synchronous Machines Rafiqi.
Chapter 6 Synchronous Motors
Three Phase Motors Maths
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
BASIC ELECTRICAL TECHNOLOGY DET 211/3
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
EEE223 Energy Conversion II Md. Asif Uddin Khan Lecturer, EEE BRAC University 1.
Synchronous Generator
EEE223 Energy Conversion II Md. Asif Uddin Khan Lecturer, EEE BRAC University.
Hafizism february 2007 EMT462 Electrical System Technology LECTURE V mohd hafiz ismail level II jejawi.
CHAPTER 10 SYNCHRONOUS MOTOR Electrical Machines.
SYNCHRONOUS GENERATOR
Lesson 18 Synchronous Motor Operation and Applications
Synchronization (Parallel Operation)
Engineering Technology Division
Lesson 34: AC Generators II
Lesson 16: Asynchronous Generators/Induction Generators
ELECTRIC CIRCUITS EIGHTH EDITION
Synchronous Motor Principle and basics.
Parallel Operation of ac generators
Synchronous Motors and Generators
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
Transformers. Transformer An A.C. device used to change high voltage low current A.C. into low voltage high current A.C. and vice-versa without changing.
UNIT II SYNCHRONOUS MOTOR.
Some practice problems
SYNCHRONOUS MACHINES Basic principles
EE216 Electrical Engineering
Utilisation of Electrical Energy
EET 306 Synchronous Machines
Electrical Machines (EELE 3351)
Power System Analysis (EELE 4351)
Presentation transcript:

SYNCHRONOUS MACHINES

EXAMPLE 6.1In a factory a 3cp, 4 kV, 400 kVA synchronous machine is installed along with other induction motors. The following are the loads on the machines:Induction motors: 500 kVA at 0.8 PF lagging.Synchronous motor: 300 kVA at 1.0 PF.(a) Compute the overall power factor of the factory loads.(b) To improve'the factory power factor, the synchronous machine is over­excited (to draw leading current) without any change in its load. With­out overloading the motor, to what extent can the factory power factor be improved? Find the current and power factor of the synchronous motor for this condition.

CONSTRUCTION OF THREE‑PHASE ‑SYNCHRONOUS MACHINES Synchronous machines can be broadly divided into two groups as follows: 1. High‑speed machines with cylindrical (or non‑salient pole) rotors. 2. Low‑speed machines with salient pole rotors.

Interconnecting synchronous generator with bus must have the same 1. Voltage 2. Frequency 3. Phase sequence 4. Phase

Voltages are not the same, but frequency and phase sequence are the The lamp voltages have equal magnitudes and therefore all the three lamps will glow with the same intensity. To make the voltages equal, the field current If must be adjusted. Frequencies are not the same, but voltages and phase sequences are the same. Equal voltages will appear across the three lamps and they will glow with the same intensity. It is therefore evident that if the frequencies are different, the lamps will darken and brighten in step. To make the frequencies the same, the speed has to be adjusted until the lamps brighten and darken very slowly in step. It may be noted that as the speed of the incoming machine is adjusted, its voltages will change. There­fore, simultaneous adjustment of the field current If will also be necessary to keep the voltages the same.

Phase sequences are not the same, but voltages and frequencies are the Phase sequences are not the same, but voltages and frequencies are the same. The voltages across the lamps are of different magnitudes and therefore the lamps will glow with different intensities. If the frequencies are slightly different, one set of phasor voltages will pass the other set of phasor voltages and the lamps will darken and brighten out of step.To make the phase sequence the same, interchange connections to two terminals; for instance, connect a to B and b to A (Fig. 6.9). Phase is not the same, but voltage, frequency, and phase sequence are the same. The two sets of phasor voltages will maintain a steady phase difference and the lamps will glow with the same intensity. To make the phase the same or the phase difference zero, the frequency of the incoming machine is slightly altered. At zero phase difference all the lamps will be dark, and if the circuit breaker is closed the incoming machine will be connected to the infinite bus. Once the synchronous machine is connected to the infinite bus, its speed cannot be changed further. However, the real power transfer from the machine to the infinite bus can be controlled by adjusting the prime mover power. The reactive power (and hence the machine power factor) can be controlled by adjusting the field current. Real and reactive power control will be discussed in detail in later sections.

6.3 SYNCHRONOUS MOTORS

Start with Variable‑Frequency Supply

EQUIVALENT CIRCUIT MODEL

6.4.1 DETERMINATION OF THE SYNCHRONOUS REACTANCE Open‑Circuit Test Short‑Circuit Test

6.4.2 PHASOR DIAGRAM Synchronous motor