Ultraviolet Disinfection - BIO-SECURITY Specification, Operation and Maintenance in a New Era 2010 Regional Aquatics Workshop Presented By: Adrian Megay.

Slides:



Advertisements
Similar presentations
O2O2 Microwave UV An Everlasting Bulb? BCWWA May 2006 Paul OCallaghan R.P.Bio O 2 ENVIRONMENTAL.
Advertisements

UV FUNDAMENTALS. F Ultraviolet is… u A Type of Electromagnetic Energy u Found Between X-Rays and Visible Light u Wavelength Range: 5 nm to 400 nm Rays.
UV Sterilizers come in many lengths and diameters The Delta UV will be used as an example. Essentially spa water flows through the stainless tube housing.
Disinfection – Chapter 26
MA Metal Finishing Forum Tools and Techniques for Optimizing Metal Finishing Process/Environmental MA Metal Finishing Forum Kevin L. Klink, P.E.
Effectiveness of Lookingglass Hatchery UV Disinfection Water System Sam Onjukka, ODFW Fish Health Services And Diane Deal, Assistant Mgr. Lookingglass.
City Water Equipment Introduction Applications Features Installation draw.
Dairy Surface Water Disinfection - Case Study -. Dairy Farm - Continental, OH 600 head of dairy cattle Milked 3 times/day Facility Background.
ULTRA VIOLET STERILISER 10Gpm – 15Gpm. Sterilight- S8Q PA 30 – 76 litres per minute S12Q PA 42 – 110 litres per minute 99.9% inactivation of even Giardia.
Ultraviolet Light Process Model Evaluation
An introduction to Ultraviolet/Visible Absorption Spectroscopy
Ultraviolet (UV) Disinfection in Water Treatment
Ultraviolet Disinfection: A Study of Various Technologies.
Start of Presentation ALLUME, LLC High Performance – Energy Efficient Lighting and Controls.
Ultraviolet (UV) Disinfection
Proven, Affordable, Environmentally Friendly …defining UV innovation…
DISINFECTION: APPROPRIATE TECHNOLOGIES FOR WASTEWATER TREATMENT KA SAMSON Presented at the APPROPRIATE TECHNOLOGY CONFERENCE BMW CENTRE, CAPE TOWN, 3-4.
A single Fly carries up to 33 million highly dangerous microbes Flies vomit every time they land They digest externally to Soften their Food Flies do.
Common Water Treatment Problems Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related.
ULTRAVIOLET (UV) RADIATION DISINFECTION
Engineers scientists architects constructors Case Study UV Disinfection Interference at Big Rapids WWTP 83 rd Annual Conference Michigan Water Environment.
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
SV Line d.o.o.1 Pause (S) Continue (N).
Treatment
ULTRA VIOLET STERILISER UV /58 US gpm Cobalt SC & SCM 600.
Flow Chart for Manufacturing Process. Choosing the optimum lead-free elements Digital pH meterParticle size analyzer Analytical labPhoto spectrometer.
Last revised March 19, 2015 Electrical Department – EQUAL CODE: EL304 Care, Use, and Maintenance of Rubber Insulating Gloves.
Microspectrophotometry Validation. Reasons for Changing Instruments Reduced reliability. Limited efficiency. Limited availability and cost of replacement.
UV Systems; Alternative Disinfectant to Free Chlorine
ULTRA VIOLET STERILISER 10Gpm – 15Gpm – 24Gpm. Sterilight – UV S12Q-PA litres per minute  99.9% inactivation of even Giardia and Cryptosporidium.
Inspection of Disinfection Components NC Certified Subsurface Systems Inspector Training School.
Unit 6.3. Ultraviolet germicidal irradiation (UVGI) TB Infection Control Training for Managers at National and Subnational Level.
Water Quality Management. Water Filtration (Mechanical)
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
بسم الله الرحمن الرحيم UMM AL-QURA UNIVERSITY Faculty of Medicine Dep. Of BIOCHEMISTRY.
Protecting people and livestock through pathogen treatment Microbiology Environmental microbiology water, wastewater, soil, air Medical microbiology, pathology,
What is the autoclave thing again. Sanitization: fancy word for Cleaning Removing of foreign material Dirt, body fluids, lubricants Using detergents,
Radiation Occupational exposures and protection A. H. Mehrparvar, MD Occupational Medicine department Yazd University of Medical Sciences.
Accessories Planned Maintenance. Types l Humidifiers l Air Cleaners l Heat Recovery Ventilators l Condensate Pumps.
Chemical Filtration Tammy Spear Kevin Landry. Types of chemical filtration There are different methods to “chemically” treat or filter the water. Some.
History of UV-C Technology
Cortez Sanitation DistrictSeptember 2002 Arber Cortez UV Disinfection Steven M. Ravel, P.E. Travis E. Meyer, P.E. Richard P. Arber Associates.
Introduction To the pr EN ISO Project norm
NSF International Drinking Water Product Standards.
Dr. Joel J. Ducoste, North Carolina State University, 1 Importance of water “Water is life” Looking at water, you might think that it's the most simple.
Human Powered Producing Potable Water for Developing Countries
OXFAM-DELAGUA Water analysis kit. OXFAM-DELAGUA water analysis kit WATSAN M15 ERU 2 Contents 1.Components 2.Capabilities 3.Maintenance 4. Summary of bacteriological.
Process Testing for Household Water Treatment Invention Megan N. Heinze, Thomas D. Jacroux, Richard P. Oleksak College of Chemical, Biological, and Environmental.
Human Powered Modular System Purpose: Create a device capable of providing basic needs to people in developing nations at a relatively low cost Focus:
‘Purification Station’ Farr High School Young Engineers.
SSi Characteristics of modern, energy efficient hydraulic systems Small reservoir volume (relative to flow rate) Most fluid in the system is in constant.
Chemical Sterilization
8. E and 4 Water Quality, Indicators, and Usage.
LED LAMP REPLACEMENT. Maintenance or Renewals? James Wickham Assets & Contracts Manager.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
A CLEAN WORLD OF MITCO CLEAN From India’s leading Concrete Tile Manufacturer Company Now In Mechanized Cleaning & Disinfection of Water Storage Tanks.
Creating a Clean and Hygienic Foodservice Operation
Public swimming pools and spa pools
MARINE AQUARIUM TANK BASICS
Chlorine Generator Advancements
NSF International Drinking Water Product Standards
DISINFECTION PROCESSES
Private Homeowner Drinking Water Issues
Water Quality, Indicators, and Usage
Infection Control Lesson 3: Surgical Asepsis
Treatment – Ultraviolet (UV)
Short & Simple • © 2018 Thinkshortcut Publishing, LLC • Created by MarketingZoo.com   It’s difficult to do because you want to start looking for valuables.
Assessment of Ozone Disinfection for Bacteria Reduction (Tanks 2 &3)
 Define: The stirring heating plate or heated stirring heating plate has been developed to heat and mix fluids contained in laboratory receptacles such.
Fluid Power System Maintenance and Troubleshooting
Presentation transcript:

Ultraviolet Disinfection - BIO-SECURITY Specification, Operation and Maintenance in a New Era 2010 Regional Aquatics Workshop Presented By: Adrian Megay

Agenda Is Bio-Security a concern?Is Bio-Security a concern? What is UV light?What is UV light? UV Benefits & LimitationsUV Benefits & Limitations How to Guarantee Selection SuccessHow to Guarantee Selection Success when choosing UV equipment for your Exhibit UV System DesignUV System Design Types of UV LampsTypes of UV Lamps and how they affect cost of ownership Selecting a UV System with confidenceSelecting a UV System with confidence The importance of routine maintenanceThe importance of routine maintenance ConclusionConclusion

Types of exhibits successfully using Ultraviolet Sterilization: Mammal Bathing Pools Reptile Pools

Types of exhibits successfully using Ultraviolet Sterilization: Avian Ponds Marine & Freshwater Aquariums Also: Quarantine/Holding Facilities & Touch Pools

What is UV Light? The Germicidal Action Spectrum Curve is identified on the Spectrum of Light chart below; of which, UV-Cs 264 nanometers is the most efficient wavelength for living microorganism disinfection.

UV Benefits UV treatment takes place only inside the UV exposure chamber. UV treatment leaves no residual downstream In contrast, chlorine/bromine leaves a residual in the water that can irritate the skin and eye tissue of mammals, reptiles, and birds. And Ozone, if not measured and controlled properly, is capable of causing severe tissue damage, even death in fish and invertebrates.

UV Limitations Exposure time between the waterborne microorganism and the UV-C light is critical to achieving successful UV disinfection. The condition of the applications water (%UVT) will determine how well the UV-C light penetrates through it. UV-C is absorbed by the targeted microorganism or by other organic waterborne particles. It is for this reason that UV equipment should be positioned after the mechanical filter.

Step One: Identify the Applications Percent UV Light Transmissibility (%UVT). %UVT and Turbidity are not synonymous! %UVT is the measurement of UV-C light transmittance in water. Contaminates and other waterborne agents will absorb UV light. Knowing the actual condition of the applications water is essential for calculating an accurate UV flow rate and ultimately achieving successful UV treatment! A credible UV Manufacturer will allow you to submit an application water sample and will provide you with %UVT test results. The test sample should represent a worse case scenario. How to Guarantee Selection Success when choosing UV equipment for your Exhibit Note: This is only a visual representation of %UVT.

The following charts demonstrate how a lower %UVT parallels a diminished UV dose when operating a 780 Watt UV Sterilizer at a flow rate of 150 GPM. How to Guarantee Selection Success when choosing UV equipment for your Exhibit

Algae: Chlorella Vulgaris Pseudomonas Fluorescens E.Coli Fecal Coliforms Amyloodinium Ocellateum Cryptocaryon Irritans Step Two: An individual microorganisms uniqueness is determined by its size, life cycle, and physical makeup, which explains why each requires a specific and different UV dose. How to Guarantee Selection Success when choosing UV equipment for your Exhibit

Identify the Targeted Microorganism and its required UV Dose for effective treatment. How to Guarantee Selection Success when choosing UV equipment for your Exhibit

Step Three: Water Flow Rate Indentify the applications minimum and maximum water flow rate. Failure to establish a proper flow rate could result in insufficient UV dosages and/or exhibit turn-over rates. Water Flow Meters are accurate measuring devices and are strongly recommended. How to Guarantee Selection Success when choosing UV equipment for your Exhibit

UV System Design The pivotal component of any UV sterilizer is its UV lamp. Critical performance characteristics include: output performance, arc length, and useful lamp life. The power source (ballast) operates the lamp and Must match its specific operating parameters (operating current and input watts). The UV reactor is essentially the space that houses the UV lamp field; the dimensions of which are based upon the lamps operating specifications. UV lamp + Ballast + UV Lamp Array

Types of UV Lamps and how they affect Cost of Ownership End of Useful Lamp Life Comparison

Types of UV Lamps and how they affect Cost of Ownership UV Lamp UV-C Output Comparison

Types of UV Lamps and how they affect Cost of Ownership UV Lamp Operating Temperature & Electrical Consumption = Optimum Application Water Temperature = Optimum Lamp Operating Temperature

Low-Pressure UV Sterilizer Systems are Cost-effective, from initial equipment purchase to the overall cost of ownership. For example: Oregon Department of Fish & Game Lookingglass Hatchery A 2,100-watt, 1,500 GPM UV Sterilizer system with 14 Lamps providing 30,000 µWs/cm 90%UVT had a daily operating cost of $ Annual replacement parts cost = $1,900 -Annual Maintenance man-hours = 3 Types of UV Lamps and how they affect Cost of Ownership

Selecting a UV System with Confidence 3 Steps to Success Third-Party Validation & Accreditation

Selecting a UV System with Confidence 3 Steps to Success Third-Party Validation & Accreditation

Routine Maintenance & Replacement Parts 1.Replace lamps per manufacturers recommended specifications : Low-Pressure typically 9,000 hours. 2.Replace quartz sleeve compression gaskets each time the corresponding lamp is changed. 3.Clean and inspect quartz sleeves periodically. It is recommended to replace Quartz Sleeves should they exhibit hairline cracks, gouges, pitting or permanent mineral deposits or stains. -To Clean Dirt: Use a mild dish washing detergent, thoroughly rinse and dry before reusing. -To Clean Calcium: Use Muriatic Acid or vinegar to dissolve the calcium, thoroughly rinse with clean water and dry before reusing. 3 Labor hours annually on a typical application.

In Conclusion Achieving Successful Germicidal Disinfection with UV The most critical factor associated with achieving successful UV disinfection is customer awareness. Buyer awareness, regarding key UV operating characteristics, can make the difference between purchasing equipment that delivers the expected result or a system that falls short of providing adequate bio-security.