EXPERIMENTAL CHARACTERISATION OF THE HIGH-PRESSURE METAL-HALIDE Na-Sc-Hg DISCHARGE Z. Miokovic 1 and D. Veza Physics Department, Faculty of Science, Uni-Zagreb,

Slides:



Advertisements
Similar presentations
Spectrochemical Instrumentation Modules
Advertisements

COST 529, April 12-16, Madeira, Portugal IAPS, University of Latvia Modelling of spectral line shapes in electrodeless discharge lamps G. Revalde 1, N.
Lecture 6 ATOMIC SPECTROSCOPY
11 CRYOPLASMA IN HELIUM INDUCED BY CORONA DISCHARGE N. Bonifaci, F. Aitken, G2Elab Grenoble, France V Atrazhev, Joint Institute for High Temperatures,
 HISTORY  CHARACTERSTICS  CONSTRUCTION  PRINCIPLE AND WORKING  LIMITATIONS  APPLICATIONS.
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Victor Gorshelev, A. Serdyuchenko, M. Buchwitz, J. Burrows, University of Bremen, Germany; N. Humpage, J. Remedios, University of Leicester, UK IMPROVED.
OPOLEOpole University Institute of Physics, Plasma Spectroscopy Group I am from.. 1.
ION BROADENING OF SODIUM nS - 3P TRANSITIONS Z. Miokovic 1 and D. Veza Physics Department, Faculty of Science, Uni-Zagreb, Bijenicka 32, HR Zagreb,
Atomic Absorption Spectroscopy (AAS) The Visible Spectra.
Natural Broadening From Heisenberg's uncertainty principle: The electron in an excited state is only there for a short time, so its energy cannot have.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
ATOMIC DATA AND STARK BROADENING OF CuI AND AgI SPECTRAL LINES: SELECTION AND ANALYSIS Radio Physics Faculty of Taras Schevchenko National University of.
Impact of the one-parameter approximation on the shape of optically-thick lines COST-529, Meeting at Mierlo, March 2006 D. Karabourniotis University of.
Spectroscopy 1: Rotational and Vibrational Spectra CHAPTER 13.
PRESSURE BROADENING AND SHIFT COEFFICIENTS FOR THE BAND OF 12 C 16 O 2 NEAR 6348 cm -1 D. CHRIS BENNER and V MALATHY DEVI Department of Physics,
Atomic Absorption Spectroscopy (AAS)
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
OPTICAL ATOMIC SPECTROMETRY Chap 8 Three major types Optical spectrometry Optical spectrometry Mass spectrometry Mass spectrometry (X-ray spectrometry)
Spatial profiles of copper atom density in a Cu/Ne hollow cathode discharge P. Hartmann*, T.M. Adamowicz**, E. Stoffels and W.W. Stoffels, Department of.
ABSTRACT An interferometer has been developed for fast, time resolved, high resolution measurements of the shape of spectral lines emitted by ionized and.
European Joint PhD Programme, Lisboa, Diagnostics of Fusion Plasmas Spectroscopy Ralph Dux.
49th Annual Meeting of the Division of Plasma Physics, November , 2007, Orlando, Florida Ion Temperature Measurements and Impurity Radiation in.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Introduction to Instrumental Analysis - Spectrophotometry
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Project Overview Laser Spectroscopy Group A. A. Ruth Department of Physics, University College Cork, Cork, Ireland.
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
Comparison of Stark Broadening and Doppler Broadening of Spectral Lines in Dense Hot Plasmas By Michael Zellner.
Chapter 10 Atomic Emission Spectrometry
Stellar Atmospheres II
Atomic Spectroscopy for Space Applications: Galactic Evolution l M. P. Ruffoni, J. C. Pickering, G. Nave, C. Allende-Prieto.
Average Lifetime Atoms stay in an excited level only for a short time (about 10-8 [sec]), and then they return to a lower energy level by spontaneous emission.
Kinetic Investigation of Collision Induced Excitation Transfer in Kr*(4p 5 5p 1 ) + Kr and Kr*(4p 5 5p 1 ) + He Mixtures Md. Humayun Kabir and Michael.
B.SC.II PAPER-B (OPTICS and LASERS)
Plasma diagnostics using spectroscopic techniques
N. Denisova, G.Revalde, A. Skudra Institute of Theoretical and Applied Mechanics, Novosibirsk, Russia Institute of Theoretical and Applied Mechanics, Novosibirsk,
Tunable, resonant heterodyne interferometer for neutral hydrogen measurements in tokamak plasmas * J.J. Moschella, R.C. Hazelton, M.D. Keitz, and C.C.
Electronic Transition of Ruthenium Monoxide Na Wang, Y. W. Ng and A. S.-C. Cheung Department of Chemistry The University of Hong Kong.
Substitute Lecturer: Jason Readle Thurs, Sept 17th, 2009
Nano-Scale Characterization: M. Pinar Mengüç RADIATIVE TRANSFER LABORATORY Mechanical Engineering Department UNIVERSITY OF KENTUCKY College of Engineering.
Gregory ClarkeTechnological Plasmas Research Group Time resolved diagnostics for pulsed magnetron plasmas.
1 Max-Planck-Institut für Plasmaphysik Cadarache 2012 K. Behringer A few comments on Opacity Calculations Using ADAS214 Cadarache, Sept K. Behringer.
Colorimeters or photometers
Spectrophotometer.
Lecture 31 General issues of spectroscopies. I. General issues of spectroscopies In this lecture, we have an overview of spectroscopies: Photon energies.
SPECTROPHOTOMETRY. Spectrophotometry Determines concentration of a substance in solution –Measures light absorbed by solution at a specific wavelength.
Evaluation of the Cu atomic density during sputter deposition process with optical emission spectroscopy Takeo Nakano, Kouji Tanaka and Shigeru Baba Dept.
Collisional Orientation Transfer Facilitated Polarization Spectroscopy Jianmei Bai, E. H. Ahmed, B. Beser, Yafei Guan, and A. M. Lyyra Temple University.
Chapter 10 Atomic Emission Spectrometry
MEASUREMENTS OF THE SHIFT AND WIDTH OF SODIUM nS - 3P TRANSITIONS IN HIGH PRESSURE SODIUM DISCHARGE IN HIGH PRESSURE SODIUM DISCHARGE Z. Miokovic 1, D.
Chapter 9 Stellar Atmospheres. Specific Intensity, I I ( or I ) is a vector (units: W m -2 Hz -1 sterad -1 )
Date of download: 6/1/2016 Copyright © 2016 SPIE. All rights reserved. (a) Vision of the Brillouin lidar operated from a helicopter. The center ray represents.
Date of download: 6/27/2016 Copyright © 2016 SPIE. All rights reserved. Schematic of the experimental setup. (1) Nd:YVO4 laser. (2) Beam expander. (3)
1 1 Office of Science Plasma control & diagnostics for 10 GeV electron beams on BELLA Work supported by: Office of Science, Office of HEP, US DoE Contract.
Zhouqian, Wan baonian and spectroscopy team
Flame Emission Spectrometry
Colorimeters or photometers
COMPARISON OF EXCITATION CONDITIONS IN
The Classical Damping Constant
Really Basic Optics Instrument Sample Sample Prep Instrument Out put
Atomic Absorption Spectroscopy
Status of Equatorial CXRS System Development
DOE Plasma Science Center Control of Plasma Kinetics
SPECTROPHOTOMETRY Applied Chemistry.
Mechanical Distortion of Single Actin Filaments Induced by External Force: Detection by Fluorescence Imaging  Togo Shimozawa, Shin'ichi Ishiwata  Biophysical.
SRF Cavity Etching Using an RF Ar/Cl2 Plasma
SPATIAL & TEMPORAL EVOLUTION OF
Presentation transcript:

EXPERIMENTAL CHARACTERISATION OF THE HIGH-PRESSURE METAL-HALIDE Na-Sc-Hg DISCHARGE Z. Miokovic 1 and D. Veza Physics Department, Faculty of Science, Uni-Zagreb, Bijenicka 32, HR Zagreb, Croatia 1 Faculty of Electrical Engineering, Uni-Osijek, K. Trpimira 2B, Osijek, Croatia MOTIVATION Better and more complete understanding of physics and chemistry of metal-halide discharge Metal-halide high intensity discharges play an increasing role as light sources Importance of atomic plasma parameters for modeling high-pressure discharges and optimization of metal-halide and alkali lamps An increasing interest for the plasma broadening of isolated non-hydrogenic lines of neutral atoms EXPERIMENT EXPERIMENT RESULTS RESULTS Fig.6.: Fig.6.: The comparison of our measured Stark shift d e of sodium 5 2 S 1/2 3 2 P 1/2,3/2 line at 615 nm, radiated from HP 400W metal-halide Na-Sc-Hg discharge with calculations by Griem. The 5 2 S 1/2 3 2 P 1/2,3/2 line was used as the calibration line to deliver values of electron densities N e at different currents through the discharge. -experiment, full line - theory (Griem, 1964) CONCLUSIONS Electron temperature is determined by Boltzmann plot method. Depending on discharge load and on the location in the discharge, the temperature is in the range of 6000 K K. Electron density is determined by measuring the Stark shift of the sodium 5 2 S 1/2 3 2 P 1/2, 3/2 spectral line. Electron densities are in the range of 7· ·10 16 cm -3. Line-shifts of the sodium 5 2 S 1/2 3 2 P 1/2, 3/2 transition show an almost linear dependence on the electron density. References [1] G. H. Reiling, JOSA 54, 532 (1964) [2]J. T. Dakin, T. H. Rautenberg, Jr. and E. M. Goldfield, J. Appl. Phys. 66 (9), 4074 (1989) [3]J. F. Waymounth, Electric Discharge Lamps (MIT, Cambridge, 1971) [4]H. Ywicker, in Plasma Diagnostics, p.214, ed. By W. Lochte-Holtgreven(Wiley, NY 1968) [5]W. L. Wiese, R. H. Huddleston, S. L. Leonard (Eds.), Plasma Diagnostics Techniques, Academic Press, NY, (1965) [6]H. R. Griem, Plasma Spectreoscopy, McGraw-Hill, New York (1964) Fig. 4.: Fig. 4.: The sodium 5 2 S 1/2 3 2 P 1/2,3/2 atomic lines measured from the HP 400W metal-halide Na-Sc-Hg discharge at the current of 3.4A. The upper part shows the sodium atomic lines measured from the low-pressure (LP) sodium spectral lamps (reference source, unshifted lines). The lower part represents the recorded spectral lines mesured, simultaneously, from the HP discharge and LP discharge. Abels inversion Fig. 3. Fig. 3. To determine the discharge temperature optically thin spectral lines wereused. The self-absorption test for spectral lines has been made by placing a concave spherical mirror behind the discharge to double the optical path length (Fig.1.). The correction for self-absorption is calculated by [5]. The solid line represents the measured line profile I 1 ( ) with single plasma length, and the dotted line represents the measured line profile I 2 ( ) with double plasma length. To obtain the line profile for optically thin case the measured profile I 1 ( ) is multiplied by the correction factor K. The dashed line is the corrected line profile I 1 C ( ). Fig. 6. Fig. 6. The electron densities are shown as a function of the current through the discharge. The electron densities show approximately a linear dependence on the discharge current. Fig. 5. The emission coefficients for the center of the discharge, of optically thin scandium spectral lines, were introduced into the Boltzmanns plot. From the slope of the regression line the electron temperature was deduced ( full line ). Dotted line - the interval of confidence according to statistical analysis. Fig. 1. Experimental arangement : LPL-low pressure lamp;HPL-high pressurelamp; R-folding mirror; L-lens; F-cut of filter; T-translator; SM-spherical mirror; M-monochromator; PMT-photomultiplier;A/D - analog-to-digital converter; PC-personal computer Fig. 2. Emission spectroscopy technique was used to measure the discharge temperature and densities of radiating atoms [3, 4]. The lateral intensity distribution, emitted by axially symmetrical plasma source, is measured. The radial intensity distribution is calculated using Abel inversion technique. The calibration of the system response has been made using a tungsten ribbon lamp.