Energy Management Opportunities with Energy Efficient Lighting

Slides:



Advertisements
Similar presentations
Saving Money Through Energy Efficiency An Overview of Energy Policy Act and the Utility Company Incentive Programs Eric W. Sank, P.E., RCDD. Design Collaborative,
Advertisements

LIGHTING AND ACOUSTICS AP 215
Click anywhere on the slide to change pages
< C ² Carbon Reduction Technology Ltd A Revolution in Lighting - The e-lamp.
Your panelists Benefits, Technologies & Services: Mike Carter and Mark Farrell, Energy Engineers.
High Performance T8 Systems Welcome DesignLights TM Consortium HPT8 High Performance T8 Systems.
H igh E fficiency L ighting P rojects Let us HELP you! Left mouse click to proceed through slide show ENERGY SERVICES GROUP.
1 1 BASICS OF ENERGY MANAGEMENT Section A - Energy Basics.
Green Energy Technologies Energy Saving and Lighting Retrofit Solutions 1.
Lighting Automation…Simplified. Energy Saving and Lighting Retrofit Solutions Energy Management Systems.
LED light fixtures Warehouse, Commercial, Industrial, Freezer and Cooler applications Before After.
EGEE 102 – Energy Conservation And Environmental Protection Energy Efficient Lighting.
Fundamentals of Efficient Lighting
Save Energy… Use Energy Saving Lamp. Introduction Electricity crisis is a common phenomenon in our country. Its a regular sufferings for the people of.
Lamps Arch 433. Choose work you love and you will never have to work a day in your life Confucius.
Origins of Induction Lighting * How It Works * Advantages and Disadvantages * Existing Products * Victory Developments * Conclusion.
Lighting – Lumens per watt Lamp typeLumens per watt Incandescent bulbs15 CFL60 Fluorescent tube HPSV100 – 150 Metal Halide lamps120 LPSV183 Light.
BASICS OF LAMP TECHNOLOGY Created by the U.S. Department of Energy Rebuild America Business Partners and Philips Lighting Company.
The Advantages of Group Relamping
Fluorescent Lamps. HOW IS LIGHT PRODUCED The fluorescent lamp produces light by the passage of an electric current flowing through a vapor of mercury.
LAMPS (Chapter 3) Lamp efficacy, life, and color Incandescent
The Latest in Energy Efficient Lighting Jeff Kramer, LC Philips Lighting Technical Support Rep.
Lighting concepts – Ballasts and Lighting Controls
Lighting Tax Deduction The Energy Efficient Commercial Buildings Tax Deduction.
Teknologi Bangunan Berkecekapan Tenaga
CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN Security Lighting.
LAPENNA CONTRACTING PRESENTS.
“Energy Efficiency Guide for Industry in Asia”
Welcome to EUROLUM GmbH Product Information Eurolum GmbH | Kirschallee. 90 | Potsdam | Tel. +49 (0) 331/ | Fax. +49 (0) 331/
1 Lighting A quick overview The Physics The Practical.
2010 Energy OutWest Reno, Nevada 12-Mar-10 Baseload Electricity quantify, address, manage 2a) Lighting baseload: effective & efficient use to shape & affect.
Northwest Power and Conservation Council Draft Deemed Measures for Commercial Lighting Retrofit Regional Technical Forum March 8, 2005.
Program Overview February 25, Program Summary Approximately $14M in incentives per year Cap for Large Customers: $300,000 per year Prescriptive.
Objectives Describe the lighting parameters Learn about lamps Define project 2.
Lighting Retrofits The low hanging fruit or is it? Kentucky Electric Cooperatives 2006 Key Accounts Technical Conference.
Restaurants Can Take a Bite Out of Energy Costs a.
XIV. MODIFYING LIGHT INTENSITY. A. Supplementary Artificial Light 1. Light Intensity and Quality Quality – nanometers Intensity – mmols/sec/m.
NCAT- Butte 3040 Continental Drive P.O. Box 3838 Butte, MT Pursuing Energy Conservation Opportunities in YOUR School.
Residential Light Fixtures ENERGY STAR ® Specifications Additions to Specs Pierrette LeBlanc, Office of Energy Efficiency June 4, 2008.
Seeing is Believing Dramatic, beautiful LED lighting Dramatic, beautiful LED lighting Warm white color Warm white color Incredible lamp life Incredible.
Linear Lamps- T8, T5 & T10 Linear Lamps- T8, T5 & T10 ver
President Parker Lighting, Inc. & Eco Induction Lighting 207 West Beach Avenue Inglewood, CA Tel: (877) 676 – 1604 Fax: (310) 674 –
KITCHEN LIGHTING BASICS ID-240 Interior Design II.
Lighting Solutions.
Lamps - Incandescent - Fluorescent - High Intensity Discharge (HID)
Lamps - Incandescent - Fluorescent - High Intensity Discharge (HID)
Energy Efficient Lighting. Overview Fundamentals –Light Quantity –Light Quality –Glare –Energy efficiency –Lighting and Productivity Inside-out Approach.
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2F: Lighting.
CA Supply C A Supply Company Your LED (Light Emitting Diodes) Lighting Supplier CA Supply Company
Presented by FSC. What is Induction? A hybrid fluorescent lamp technology first introduced in 1891 that eliminates the need for electrode and filaments.
| _ T12: 12/8" T8: 8/8" T5: 5/8" The Shrinking Fluorescent.
T5 Lamp/Fixture Technology The T5 lamp, and lighting fixture combo is the most exciting technology to be introduced in years!
Conserving Resources for the Future…Today. T5 Lighting Retrofit Solutions To replace outdated T12 and T8 Fluorescent lighting 1.
LED light fixtures Warehouse, Commercial, Industrial, Freezer and Cooler applications Before After.
H igh E fficiency L ighting P rojects Let us HELP you! Left mouse click to proceed through slide show ENERGY SERVICES GROUP.
Dr. Mike Nofziger 2010 Sources of Light Fire– rapid oxidation of a combustible material – heat and light are emitted in the process Flame– visible light-emitting.
1 Dummerston Energy Committee 2 a Dummerston Energy Committee Accomplishments Covered Bridge LED lighting upgrade Before After Exterior Lighting.
Why is light important? 1.) Photosynthesis (chl & light) 6CO H 2 O (chl & light) C 6 H 12 O 6 + 6O 2 + 6H 2 O 2.) Needed for chlorophyll production.
Created by Susan Neal $100 Fractions Addition Fractions Subtraction Fractions Multiplication Fractions Division General $200 $300 $400 $500 $100 $200.
Equal or Not. Equal or Not
Energy Efficiency 4/29/2015 Lighting Akrem Awad 1.
Energy Efficient LED Lights Mohammad Alhasawi Managing Director and partner Green Tech Solutions co w.l.l. 1.
Lighting. Artificial Light Units of Measurement Input Power – Watts Light Output – Lumens Efficacy* (of light source) – Lumens per watt Efficiency (of.
Energy retrofit solution for 400w MH Highbays!! Question:How many fixture lumens do you need to replace one 400w MH highbay? Answer:About 20,000 lumens.
ENME808W Advanced Topics in Mechanical Engineering: Energy Efficiency/Energy Audit and Conservation Week Eleven Lecture I: Dr. Michael Ohadi Class: Mon.
EISA 2007 More than Incandescent Bulbs. Review: Incandescent Bulbs and the Energy Independence and Security Act of 2007:
INCANDESCENT LIGHT SOURCES
LIGHTING SYSTEMS. Introduction  Electricity used to operate lighting systems represents a significant percentage of electricity consumed in most countries.
Lamps Chapter 5 © 2006 Fairchild Publications, Inc.
Objectives Describe the lighting parameters Learn about lamps
Presentation transcript:

Energy Management Opportunities with Energy Efficient Lighting

Your panelists Benefits, Technologies & Services: Mike Carter and Mark Farrell, Energy Engineers

Lighting webinar benefits Bottom line cost savings today! Comfortable speaking with customers Knowledge of terms and pros/cons Awareness of energy efficiency opportunities (4.89) 30.4% Large Office Building

Contents Energy Basics Fundamentals of Light Lighting Technologies Lighting Controls Lighting Maintenance Business Solutions Toolkit Incentives/Rebates

Energy basics Power versus Energy Kilowatt (kW) is a measure of power, like the speedometer of your car that records the rate at which miles are traveled. A bigger engine is required to travel at a faster rate. Kilowatt-hour (kWh) is a measure of energy consumption, like the odometer on your car (miles). Energy cost = power (kW) x time (hrs) x price = kWh x $/kWh A 113-watt four lamp light fixture costs about $66 annually when operating 16 hr/day (113 W x 5,840 hr x $0.10/kWh ÷ 1,000 W/kW). Source: stock.xchng Source: Commonwealth of Kentucky

Lights do not consume more energy when they are first turned on. Energy basics Lights do not consume more energy when they are first turned on. Includes high-intensity discharge (HID) lighting. Pay the price for improved energy efficiency! The operating cost over the lifetime of a light fixture can far exceed the original purchase price.

Fundamentals of light Lumens—A measure of the perceived power of light. Constant output regardless of distance from source. Foot-candle—One lumen of light distributed over a square foot area. Depends on the distance from the light source. Does not hold for focused fixtures like flood lamps. Can be measured using light meter.

Lighting has many metrics. Lighting comparison Lighting has many metrics. 60-watt incandescent ~ 850 lumens (100 CRI) ~ 14 lpw efficacy 32-watt T8 fluorescent ~ 2,800 lumens (83 CRI) ~ 88 lpw 400-watt metal halide ~ 24,000 lumens (65 CRI) ~ 60 lpw 400-watt high-pressure sodium ~ 45,000 lumens (22 CRI) ~ 112 lpw

Incandescent / halogen 90% heat and 10% light (10 to 17 lumens per watt) Energy Independence and Security Act (EISA) of 2007 establishes higher minimum efficiency standards for incandescent reflector lamps (R lamps). Parabolic Aluminized Reflector (PAR#) lamps BR# (Bulged) and ER# (Ellipsoidal) # —the diameter of the widest part of the lamp in eighths of an inch (R20 = 20/8 = 2.5" diameter) EISA applies to > 2.25 " diameter

Incandescent / halogen Flood lights Beam angle encompasses that part of the beam that varies from peak | brightness down to 50% of that intensity as measured in a plane through the nominal beam centerline. New halogen bulbs offer up to 30% energy savings, instant on, no mercury, 100 CRI, and compliance with EISA 2007. Philips Halogena® Energy Saver/Energy Advantage (3,000 hrs) Sylvania Halogen SuperSaver® (1,000 hrs) GE Edison™ (2,500 hrs) Source: Philips Lighting

Fluorescent Historical timeline 1838—Michael Faraday’s glow tubes 1850s—Glass-blower Heinrich Geissler 1880s—Alexandre E. Becquerel coated tubes 1893—Nikola Tesla induction tubes 1896—Thomas Edison patented x-ray lamp 1890s—Daniel McFarlane Moore 1901—Peter Cooper Hewitt mercury vapor lamp 1927—Edmund Germer patent 1936—GE’s George E. Inman patent 1938—First commercial fluorescent tubes

Fluorescent Nomenclature (FxxT#) F—fluorescent Fxx—wattage (rapid start) or length (instant start) T- tubular; U—curved/bent Circline—circle T#—diameter in eighths of an inch Ballast Factor (BF)—ratio of output compared to reference ballast (not energy efficiency measure) Affects both watts and lumens Ranges from 0.6 to 1.3 Fluorescent light emission is a chain reaction.

Fluorescent T8 Types (Generations) Type Name Watts Lumens CRI Life (hrs, 000s) 1G 700 Series, Basic 32 W 2,800 75-78 15-20 2G 800 Series 2,850 -3,000 82-86 24-30 3G Super, HO 2,950 - 3,200 4G Reduced Wattage, Energy Savers 23 W 25 W 28 W 30 W 2,000 2,400 2,750 2,850 Temp. sensitive, Instant start only

Fluorescent Super T8 lamps, with high-efficiency ballasts, are high-lumen (>3000 versus 2,850 standard) and extended life (>24,000 versus 20,000 hours standard) products. Only saves energy when combined with a lower ballast factor ballast. T5 series (good for indirect lighting like suspended lighting). Type Initial Lumens Watts Ballast Factor Fixture Lumens Fixture Watts LPW T8 2,950 33 0.85 2,496 28 89 Super T8 3,200 34 0.78 26 96 Type Initial Lumens Watts LPW Life T5 2,900 28 W 104 24,000 hours T5HO 5,000 54 W 93

Fluorescent T8 versus T5 T5s (smaller diameter and shorter) not interchangeable with T8s. Six F32T8s equivalent to four F54T5HO. T5s have lower mercury content than T8s. T5 lumen maintenance better at higher ambient temperatures but worse in cold. Holophane IntelliBay™ & IntelliVue™ Lithonia I-BEAM™ System Source: RPI Lighting Research Center

Four-lamp T12 versus T8 Fixtures Fluorescent Replace existing T12 fluorescent lamps with T8 fluorescent lamps (up to 30% savings). Start modes Programmed start (in series) Long preheat shuts down after start (up to 50,000 cycles). Can be wired in parallel Rapid start (in series) Simultaneous preheat stays on all the time (15,000 to 20,000 cycles). Identified by 2-wires from ballast to each end of lamp. Instant start (in parallel) No-preheat; high-voltage start (10,000 to 15,000 cycles). Identified by 1-wire from ballast to each end of lamp. Not good with occupancy sensors (<30 minute burn). Four-lamp T12 versus T8 Fixtures Lamp Type Fixture Watts Fixture Lumens LPW F32T12 148 9,120 62 F32T8 113 10,600 94

Fluorescent Fluorescent ballasts Magnetic (60 Hz) Core and coil Electronic (20 to 60 kHz) 10% to 15% more efficient NEMA Premium® Ballasts even better All ballasts consume power even without lamps (2-lamp example). Electronic consumes 6 to 12 watts loaded and 3 to 7 watts open circuit. Magnetic consumes 18 to 20 watts loaded and 6 to 10 watts open circuit. Regulatory driver for electronic ballasts (T8 and T5 lamps) No magnetic ballasts manufactured for replacement after June 2010. 2009 DOE Energy Regulations—Beginning July 14, 2012, these regulations effectively eliminate most 4-ft T12, 8-ft (F96) T12 lamps, and 700 series (1st generation) T8 lamps

Fluorescent Metal Halide (MH) versus Fluorescent for High-bay Probe start (PS) MH with low lumen maintenance (<65%) is best target for replacement. EISA2007 imparts higher performance standards for PS MH. The lumen maintenance of metal halides can decrease to 45% during its lifetime, whereas fluorescents maintain 90% to 95% in optimal conditions. Comparison One PS MH with 20,000 EOL lumens at 320 system watts Six F32T8 with 18,000 EOL lumens at 220 system watts Remember—lumen output of fluorescents declines with heat/cold.

Fluorescent Compact Fluorescent Lighting (CFL) You get the same or more light output (lumens) with a 75% energy reduction and over six times the rated life! Up to 9,000 lumen output at 120 watts (PL-H high 4-pin) Energy savings far outweigh difference in lamp price. Power factor is typically 0.6, but power savings far outweighs low power factor. Issue of mercury content can be addressed. Use reflector flood CFLs (R-CFLs) in recessed can lights. Consider aluminum reflector CFL PAR lamps. Globes Candelabra Source: NREL

Fluorescent Compact Fluorescent Lighting (CFL) Twister Single, double (T), triple (TR), quadruple (Q) twin-tube (turns) Integral ballast screw-in Modular external ballast pin-based Gxx where xx is pin center-to-center dimension (G23 has 23mm dimension) G23q where “q” means quad-pin base G23d-x where “d-x” means the number of tubes (turns) 2-pin with integral starter requires magnetic preheat ballast 4-pin (quad) with external starter usually electronic ballast

Fluorescent Induction (electrodeless) lighting High-frequency magnetron microwave power generator, magnetic field coupling device (antenna), and phosphor coated tube. Up to 100,000 hour rated lamp life Lumen maintenance 70% at 60,000 hours Efficacy of 70 to 75 lumens per watt Best applications have high labor cost. Parking garages Cold-storage rooms Inaccessible roadway tunnels and underpasses Illumination of roadway signs and inaccessible advertisement boards Lighting over stairs or escalator wells Open mall atriums or ceilings in "big box" retail areas Pole-mounted luminaires for dusk-to-dawn illumination on a campus Industry, petrochemical, and offshore applications Source: Osram Endura/Sylvania IcetronTM Electrodeless Lamp

High Intensity Discharge Low Pressure Sodium Most energy efficient lighting source Not an arc source, so no glare 0 to 20 CRI High Pressure Sodium Arc source with (20 to 65 CRI) 310 W and 360 W replacements exist for 400 W Electronic ballasts 5 to 20 W versus 50 to 70 W magnetic

High Intensity Discharge Metal Halide Arc source with 60 to 95 CRI Quartz or ceramic transparent tubes Ceramic (polycrystalline alumina—PCA) offers better lumen maintenance, color rendering (95 versus 65 CRI), and color stability. Can operate on HPS ballasts (direct lamp replacement). Smaller Size <150W HID Ballasts Generally 50% smaller in size (3" x 1.3" x 1.1") and lighter weight than standard magnetic ballasts Self-ballasted PAR30LN and PAR38 (1,200 initial lumens) CMH lamps replace 74W and 120W halogen bulbs Source: Osram-Sylvania

High Intensity Discharge Sustained arc vs. fluorescent phosphor emission Strike time (minutes) Type Watts Lumens Lumen Maintenance LPW CRI Life (hrs) Mercury Vapor* 1,000 W 47,500 65% 30 40 24,000 Low Pressure Sodium 135 W 22,000 >95% 150 10 18,000 High Pressure Sodium 400 W 45,000 75% 85 24,000+ Metal Halide** 452 W 40,000 70% 65 20,000 *Ballasts banned by EPAct2005 **Position dependent MV LPS HPS MH Probe MH Pulse Warm up 4-7 7-15 1-4 2-15 Restrike 3-6 1 0.5-1 5-20 2-8

High Intensity Discharge Radio Frequency Lighting Luxim LiFi™ or Light Emitting Plasma™ (LEP) An ac/dc converter generates an RF signal that is transmitted by a special cable to a quartz lamp embedded in a dielectric material. Pemco Lighting Products STA-41-01 luminaire 273 system watts 23,000 initial lumens 5,500K CCT/80 CRI 50,000 hour rated life Dimmable to 20% Source: Luxim

Solid state lighting Light Emitting Diodes (LEDs) Electrical current driver circuit instead of ballast. Relatively low lumens per watt (30 to 35 lpw) historically, but now 45 to 60 lpw. Long life; years, not hours. 70% lumen maintenance at 50,000 hours of operation. Frequent switching does not affect rated life for LEDs as it does for fluorescents. Directional nature of LED results in very high luminaire efficacy. Very compact and low-profile. Nothing to “break.” No abrupt failure mode. Source: NIST

Solid state lighting Light Emitting Diodes (LEDs) Instant on (no warm-up time required). Does generate harmonics, but no reported problems. Some built-in surge and noise protection. Expensive initial cost. Heat sensitive. Exit Signs Annual operating costs of $5 compared to $30 to $40 for incandescent or fluorescent. Compatible with battery backup (traffic lights). Source: stock.xchng

Lighting controls Occupancy sensors Daylighting Skylights/lightpipes, clerestory windows, or roof monitors. Energy savings can range from about $0.25/ft2 to $0.50/ft2, depending on the building type, location, office area plan, and local cost of energy. Photosensor layout is important. Source: LightLouver LLC Occupancy sensors Ultrasonic has wider range than infrared but is prone to false positives. Can shorten life of fluorescents with instant start ballast. $30 to $150 cost. 2-year payback is normal.

Lighting controls Dimming A solid-state dimmer works by using silicon-controlled rectifiers (SCRs). Radio frequency interference (RFI) can be a problem. Greatly increases bulb life for incandescent/halogens. Requires special dimming ballast for fluorescents. 3-wire, 2-wire, or 4-wire. Energy savings fairly linear with fluorescents. Continuous or bi-level dimming HID lighting limited to 50% to 60% dimming. Two-level for magnetic ballasts (non-linear energy savings). Continuous for electronic ballasts (energy savings linear). Lamp life degrades if dimming to less than 60% level.

Lighting controls Digital Addressable Lighting Interface (DALI) A royalty-free, non-proprietary, two-way, open and interoperable digital protocol. The Gateway broadcasts commands to all digital ballasts across the signal cabling that connects the ballasts in parallel. A ballast only responds when the message contains its specific address. Sixteen programmable scenarios and groups stored in the ballast.

Wireless Mesh Networks Lighting controls Wireless Mesh Networks Redundant Joining Healing Spatial diversity Different routes Temporal diversity Try again later Source: Dust Networks

Lighting maintenance Nine components of a good lighting maintenance program*: Group relamping Know your equipment Focusing and adjustment Verify lamp types and wattage Verify color temperature Confirm that everything is in working order Watch for compatibility issues Get rid of dirt Do not forget exterior lighting *"Everything You Need to Know About Maintaining Your Lighting System," by Jean Sundin, founder of Office for Visual Interaction, Inc.

Lighting maintenance Group relamping recommended at 60% to 80% of rated life. Every 2 to 3 years for 20,000 hour fluorescents. Can be 30% to 40% cheaper to group relamp due to labor savings. Easier to schedule and outsource than spot relamping. Reduces improper mixing of different types of lamps. Normally done outside working hours. Lighting failure modes Heat Voltage transients Vibration Bad electrical connection Improper cycling

The Business Solutions Toolkit Reduce energy expenditures with free, online tools Energy benchmark data by business segment Efficiency recommendations by business segment Lighting, motor and other energy calculators Facility energy assessment… plus more Get energy answers with live Web resources “Ask an Expert” service supplies direct answers to energy questions Searchable Energy Library and News resources Monthly electronic newsletter delivered to your e-mailbox

How to access the Toolkit Links found on the Pacific Power website Can access direct at pacificpower.net/toolkit Register to use the Toolkit and you will receive our monthly e-mail newsletter

What is in the Toolkit

Online business tools pacificpower.net/toolkit

Pacific Power FinAnswer Express FinAnswer Express is for commercial and industrial customers– either retrofit or new construction Pre-calculated incentives for high-efficiency lighting and HVAC equipment Custom incentives may be available for other types of equipment Incentive process (pre-purchase agreement or post purchase application) varies by technology and project type Please understand the process before you purchase! Check our website for on-line forms plus trade allies available to help Also check for state and federal tax incentives at dsireusa.org

Pacific Power Energy FinAnswer Applies to comprehensive commercial or industrial projects– either new construction or commercial retrofit* Lighting and non-lighting projects can be packaged Starts with an energy analysis to identify options and highest priority measures Commissioning is required for most measures Incentives are project-based Payable by one-time lump sum check, per project Incentive agreement must be signed before equipment is purchased Check our website for participation steps and online forms *Commercial retrofit projects must be at least 20,000 sq. ft. to be eligible

Contacts For more information please phone us: Visit our website at: Call your Business Solutions Team for answers to service and account questions at 1-866-870-3419 Visit our website at: Business program Web page – pacificpower.net/business Business Solutions Toolkit – pacificpower.net/toolkit Or contact us directly: E-mail us at energy.expert@pacificorp.com Use our online inquiry form – pacificpower.net/inquiry Call our business Energy Services Hotline at 1-800-222-4335 Also visit the Energy Trust of Oregon website at energytrust.org © 2010 Tech Resources Inc.