In vitro comparison of different mechanical prostheses suitable for replacement of the systemic atrioventricular valve in children  Tomaso Bottio, MD,

Slides:



Advertisements
Similar presentations
Max B. Mitchell, MD  The Journal of Thoracic and Cardiovascular Surgery 
Advertisements

Of mice and men and surgical transcatheter aortic valve insertion
Lost in translation The Journal of Thoracic and Cardiovascular Surgery
Manuel J. Antunes, MD, PhD, DSc 
A cherry blossom moment in the history of heart valve replacement
Prospective randomized comparison of CarboMedics and St
Bigger valve size is not always better
Form ever follows function
William M. DeCampli, MD, PhD 
Functional mitral stenosis after mitral valve repair is a true anatomic problem that originates from the time of surgery  Vincent Chan, MD, MPH, Thierry.
It is still mostly about the mitral valve
Early degeneration of the St Jude Medical Trifecta bioprosthetic aortic valve: A problem of the leaflets or of the stent?  Giuseppe Santarpino, MD, Steffen.
Go on-pump or off-pump in diabetic patients?
Where is the common sense in aortic valve replacement
Bicuspid aortic valve aortopathy: One size fits all?
Jennifer S. Lawton, MD, Nader Moazami, MD, Michael K
Surgeons, valve repair in severely unbalanced atrioventricular septal defect, and the emperor's new clothes  David M. Overman, MD  The Journal of Thoracic.
Bigger The Journal of Thoracic and Cardiovascular Surgery
The lord of the rings  Antonio Miceli, MD, PhD 
Gastric conduit revision after esophagectomy: The raising of Lazarus
Aldo R. Castañeda, MD, PhD: Recipient of the Lifetime Achievement Award and 74th president of The American Association for Thoracic Surgery  Pedro J.
The variability of the mitral valve anatomy and terminology
Outcomes after mechanical aortic valve replacement in children and young adults with congenital heart disease  Patrick O. Myers, MD, Suyog A. Mokashi,
Quality of mitral valve surgery at the United States Department of Veterans Affairs  Juan A. Crestanello, MD  The Journal of Thoracic and Cardiovascular.
Innovation and science: The future of valve design
The assessment of cost effectiveness and the effectiveness of cost assessment in cardiothoracic surgery  Vinay Badhwar, MD  The Journal of Thoracic and.
It's not “just a shunt” but sometimes it should be…
Structural deterioration of the Freestyle aortic valve: Mode of presentation and mechanisms  Siamak Mohammadi, MD, Richard Baillot, MD, Pierre Voisine,
Michele Gallo, MD, Gino Gerosa, MD 
Military surgeons just want to have fun
A first start for lung transplantation?
Intermediate results of isolated mitral valve replacement with a Biocor porcine valve  Giulio Rizzoli, MD, Tomaso Bottio, MD, PhD, Vladimiro Vida, MD,
Jules Lin, MD  The Journal of Thoracic and Cardiovascular Surgery 
The aortic valve–sparing operation
Transcatheter aortic valve replacement and surgical aortic valve replacement: Both excellent therapies  J. James Edelman, MBBS(Hons), PhD, Vinod H. Thourani,
Commentary: It's time to check our bias: Ensuring health equity for patients with lung cancer  Pamela Samson, MD, MPHS  The Journal of Thoracic and Cardiovascular.
Torsten Doenst, MD, PhD, Markus Richter, MD 
Surgery for aortic and mitral valve disease in the United States: A trend of change in surgical practice between 1998 and 2005  Scott D. Barnett, PhD,
Joseph A. Dearani, MD, Michael J. Ackerman, MD, PhD 
A cherry blossom moment in the history of heart valve replacement
Vivek Rao, MD, PhD, Carolyn M. David, BN 
Resection of primary lung cancer with incidental pleural seeding: Seeds of change or reap what you sow?  Jules Lin, MD  The Journal of Thoracic and Cardiovascular.
Fenton H. McCarthy, MD, MS, Nimesh D. Desai, MD, PhD 
Replicating the success of mitral valve repair in the aortic valve
Manuel J. Antunes, MD, PhD, DSc 
Thirty-year experience with a bileaflet mechanical valve prosthesis
St Jude Medical Regent valve
Passing the torch The Journal of Thoracic and Cardiovascular Surgery
Biomaterials for heart valve replacement: Conjectures and refutations
Warfarin or aspirin after mitral valve repair: Why work harder?
Hans-Joachim Schäfers, MD 
Innovation in cardiothoracic surgical training
Preserving the V-engine shape of the left ventricle with Melody mitral valve replacement in small children  Patrick O. Myers, MD  The Journal of Thoracic.
The Journal of Thoracic and Cardiovascular Surgery
Discussion The Journal of Thoracic and Cardiovascular Surgery
Tissue valve, nitinol stent, or storage solution
The future of cardiac surgery training: A survival guide
Permanent pacemaker insertion following transcatheter aortic valve replacement: Not infrequent, not benign, and becoming predictable  Craig M. Jarrett,
Another case of underprovision of mitral valve repair surgery: Lessons from the Veterans Affairs health system  Anelechi C. Anyanwu, MD, David H. Adams,
Commentary: Have mitral valve simulators made it to reality?
Pasquale Totaro, MD, Vincenzo Argano, MD 
“The more things change…”: The challenges ahead
Intermittent incomplete closure of Medtronic Advantage aortic valve leaflets causes unnecessary reoperation  Rune Haaverstad, MD, PhD, Nicola Vitale,
Francesco Nappi, MD, Cristiano Spadaccio, MD, PhD 
Preoperative PFTs: The answer is blowing in the wind
Did you like Terminator 3 better than Terminator 2
Journal changes and initiatives
Lessons learned from Melody valve retrieved at transplantation
Edward Y. Chan, MD, Michael J. Reardon, MD 
Calpain inhibitors: The aspirin of the 21st century?
Presentation transcript:

In vitro comparison of different mechanical prostheses suitable for replacement of the systemic atrioventricular valve in children  Tomaso Bottio, MD, PhD, Carlo Dal Lin, MD, Alban Lika, MD, Giulio Rizzoli, MD, Vincenzo Tarzia, MD, Edward Buratto, MD, Gino Gerosa, MD  The Journal of Thoracic and Cardiovascular Surgery  Volume 143, Issue 3, Pages 558-568 (March 2012) DOI: 10.1016/j.jtcvs.2011.05.033 Copyright © 2012 The American Association for Thoracic Surgery Terms and Conditions

Figure 1 The SPD. (Reprinted with permission from the SPD Instructions Manual, page 5.9) The Journal of Thoracic and Cardiovascular Surgery 2012 143, 558-568DOI: (10.1016/j.jtcvs.2011.05.033) Copyright © 2012 The American Association for Thoracic Surgery Terms and Conditions

Figure 2 Mitral timing points. (Reprinted with permission from the SPD Instructions Manual, page 35.9) The Journal of Thoracic and Cardiovascular Surgery 2012 143, 558-568DOI: (10.1016/j.jtcvs.2011.05.033) Copyright © 2012 The American Association for Thoracic Surgery Terms and Conditions

Figure 3 The valves inserted into the SPD holder (21 mm), which is composed of 2 O-rings. Each prosthesis was secured between these rings fitting perfectly, thus ensuring the lack of any perivalvular leakage, as shown: On-X (On-X Life Technologies, Inc, Austin, Tex); SJM Regent (St Jude Medical Inc, St Paul, Minn); and Sorin Overline (Sorin Biomedica, Saluggia, Italy). The Medtronic Advantage (Medtronic Inc, Minneapolis, Minn) is shown in the SPD during the tests. The Journal of Thoracic and Cardiovascular Surgery 2012 143, 558-568DOI: (10.1016/j.jtcvs.2011.05.033) Copyright © 2012 The American Association for Thoracic Surgery Terms and Conditions

Figure 4 Mean pressure difference, EOA, and VCV of all valves tested. The Journal of Thoracic and Cardiovascular Surgery 2012 143, 558-568DOI: (10.1016/j.jtcvs.2011.05.033) Copyright © 2012 The American Association for Thoracic Surgery Terms and Conditions